Relationship Between Acupuncture Needling Direction and Electric Current
Meridian Study on the Response Current Affected by Acupuncture Needling Direction
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Acupuncture manipulation with needling direction is important for the therapeutic effect based on traditional Chinese medicine theory. However, research usually focuses on the therapeutic effects on the acupoints and acupuncture time rather than on the manipulation method. This study applies a semiconductor analyzer to investigate the effects of acupuncture manipulation.
30 healthy participants were recruited in the study. This study employed an Agilent B1500A semiconductor analyzer to investigate the electric characteristics of meridians under directional supplementation and draining manipulation. We measured the electric current of meridians under different manipulation, and compared the difference between supplementation and draining manipulation in healthy individuals.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Kaohsiung, Taiwan, 833
- Kaohsiung Chang Gung Memorial Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- at least 20 years old
- agree to the informed consent
Exclusion Criteria:
- under 20 years old
- pregnant or breast-feeding women
- those with an empty stomach before the study
- a tendency toward bleeding with thrombocytopenia or history of platelets < 20000 or a user of an anti-platelet drug.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: acupuncture with manipulation group
30 participant were recruited in this study. All the participants received acupuncture at the acupoints (HT7、HT3、SI5、SI8、BL57、BL40、KI3、KI10) and were measured by an Agilent B1500A semiconductor analyzer. The investigator perform acupuncture with supplementation manipulation first, followed by a measurement of the electrical characteristics using Agilent B1500A. The investigator remove the acupuncture and then perform acupuncture with draining manipulation, followed by measurements. After one meridian measurements were completed, the investigator removed the needle and proceeded to the next meridian to repeat the same procedure. |
The investigator used directional supplementation and draining manipulation.
The supplementation manipulation is defined as the angle of needle insertion to skin as 45 degrees with the needle tip in the same direction as the meridian.
While the draining manipulation is defined as the angle of needle insertion at 45 degrees with the needle tip direction opposite to that of the meridian.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
The electric current
Time Frame: through study completion, an average of 90 minutes
|
Agilent B1500A is a device that can measure the electric current after acupuncture manipulation.
The investigators measure the electric current after intervention of supplementation manipulation and draining manipulation respectively.
|
through study completion, an average of 90 minutes
|
|
The voltage
Time Frame: through study completion, an average of 90 minutes
|
Agilent B1500A is a device that can measure the voltage after acupuncture manipulation.
The investigators measure the voltage after intervention of supplementation manipulation and draining manipulation respectively.
|
through study completion, an average of 90 minutes
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Yu-Chiang Hung, Professor, Chang Gung Memorial Hospital
Publications and helpful links
General Publications
- Hung YC, Chen WC, Chang TC, Zheng HX, Liu YW, Tan YF, Lin SK, Lu YH, Hu WL, Tsai TM. Meridian study on the response current affected by electrical pulse and acupuncture. Nanoscale Res Lett. 2020 Jul 10;15(1):146. doi: 10.1186/s11671-020-03373-2.
- Ifrim Chen F, Antochi AD, Barbilian AG. Acupuncture and the retrospect of its modern research. Rom J Morphol Embryol. 2019;60(2):411-418.
- Zhang WB, Wang GJ, Fuxe K. Classic and Modern Meridian Studies: A Review of Low Hydraulic Resistance Channels along Meridians and Their Relevance for Therapeutic Effects in Traditional Chinese Medicine. Evid Based Complement Alternat Med. 2015;2015:410979. doi: 10.1155/2015/410979. Epub 2015 Mar 2.
- Lin CH, Tan YF, Tseng ST, Chen WC, Kuo CW, Wu CC, Tsai TM, Hu WL, Chang TC, Hung YC. Meridian study on the response current affected by acupuncture needling direction. Medicine (Baltimore). 2022 Sep 2;101(35):e30338. doi: 10.1097/MD.0000000000030338.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 201901601A3
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.