Evaluating the Non-Inferiority of Airmod to Capnostream™35
Evaluating the Non-Inferiority of Airmod to Capnostream™35 on Respiratory Rate Monitoring and User Experience Clinical Evaluation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Yuan Ren Cheng, MS
- Phone Number: +886918062948
- Email: infie.cheng@heroic-faith.com
Study Locations
-
-
-
New Taipei City, Taiwan, 237
- En Chu Kong Hospital
-
Taipei City, Taiwan, 106
- Cathay General Hospital
-
Taipei City, Taiwan, 10491
- Mackay Memorial Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Provision of signed and dated informed consent form.
- Stated willingness to comply with all study procedures and availability for the duration of the study.
- Male or female with at least 20 years of age.
- Fit for intravenous general anesthesia (IVG) as assessed by pre-anesthesia evaluation.
Exclusion Criteria:
- Presence of neck pain or injuries.
- Under the use of high-flow nasal cannula ventilation. Patients with advanced airway management equipment. (For instance, Supraglottic airway device, LMA, Endotracheal tube.) Some equipment, such as High Flow Nasal Cannula (HFNC), CPAP, suction machine, could continually make noise in the patient's airway, affecting auscultation and RR measurement.
- Unable to wear Airmod and Capnostream™35 device related accessories at the investigator's discretion.
- As a vulnerable population, including legal incapacity or evidence that a subject cannot understand the purpose and risks of the study, regardless of authorized representative support.
- Unwilling or unable to comply fully with study procedures (including non-toleration of the capnography cannula) due to any disease condition which can raise doubt about compliance and influencing the study outcome.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Airmod
The experimental device are installed in the same patient as the reference device to compare the non-inferiority of the respiratory rate measurement.
|
Both of the respiratory rate monitor (including experimental and reference device) are installed on the enrolled patients.
The practitioners can clearly read the result of both devices.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Test of the Difference Between airRR and mancRR
Time Frame: up to 4 hours
|
The mean difference is based on the comparative pair (reference: mancRR - device under test: airRR) (unit: BPM) The measurement of airRR (airmod recorded breathing rate per minute: BPM ) (minimal: 4 BPM, maximal: 35BPM) The measurement of mancRR (manual scored capnography breathing rate per minute: BPM) (minimal : 0 BPM, maximal 39BPM)
|
up to 4 hours
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Analysis to Assess the Accuracy of Respiratory Rate Measurement by Airmod in Comparison With Manual-scored Auscultation Sound During the Less Sensitive Period of Capnography on Capnostream™35
Time Frame: up to 4 hours
|
The mean difference is based on the comparative pair (reference: acoRR - device under test: airRR) (unit: BPM) The measurement of airRR (airmod recorded breathing rate per minute: BPM ) (minimal: 4 BPM, maximal: 35BPM) The measurement of acoRR (manual scored auscultation sound breathing rate per minute: BPM) (minimal : 0 BPM, maximal 60BPM)
|
up to 4 hours
|
|
Analysis to Measure the Agreement Between AirRR and ManCRR (Limits of Agreement and Bland-Altman Plots)
Time Frame: up to 4 hours
|
The Bland-Altman plot and limits of agreement compare the following respiratory rates, all measured in BPM: airRR (Airmod recorded respiratory rate), capRR (capnography recorded respiratory rate), and acoRR (manually scored auscultation respiratory rate) against mancRR (manually scored capnography respiratory rate).
|
up to 4 hours
|
|
Analysis to Evaluate the Response Time of the First Breath Detection Followed by Administration of Jaw Thrust During the Apnea Period
Time Frame: up to 4 hours
|
We examined the response time for detecting the first breath after administering a jaw thrust maneuver during an apnea period.
The results included the latency of the Airmod breathing response (measured in seconds), the latency of capnography (measured in seconds), and the difference in latency between Airmod and capnography (measured in seconds).
|
up to 4 hours
|
|
Analysis to Compare the Influence of Subjects to Variated Breath Rates on Respiratory Rate Monitoring in Bpm as Measured by Airmod, Manual-scored and Capnostream™35
Time Frame: up to 4 hours
|
The mean difference is based on the comparative pair (reference: mancRR - device under test: airRR) (unit: BPM) The measurement of airRR (airmod recorded breathing rate per minute: BPM ) (minimal: 4 BPM, maximal: 35BPM) The measurement of mancRR (manual scored capnography breathing rate per minute: BPM) (minimal : 0 BPM, maximal 39BPM).
|
up to 4 hours
|
|
Safety and Usability of Airmod.
Time Frame: In the study , All participants spend less than 30 min writing thesis questionnaire.
|
Questionnaire response from research staff, each question score 0 or 1 by candidate, the result stands for successful numbers over all candidates in specific question.
|
In the study , All participants spend less than 30 min writing thesis questionnaire.
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
General Publications
- Atkins JH, Mandel JE. Performance of Masimo rainbow acoustic monitoring for tracking changing respiratory rates under laryngeal mask airway general anesthesia for surgical procedures in the operating room: a prospective observational study. Anesth Analg. 2014 Dec;119(6):1307-14. doi: 10.1213/ANE.0000000000000362.
- Hsu FS, Huang SR, Huang CW, Huang CJ, Cheng YR, Chen CC, Hsiao J, Chen CW, Chen LC, Lai YC, Hsu BF, Lin NJ, Tsai WL, Wu YL, Tseng TL, Tseng CT, Chen YT, Lai F. Benchmarking of eight recurrent neural network variants for breath phase and adventitious sound detection on a self-developed open-access lung sound database-HF_Lung_V1. PLoS One. 2021 Jul 1;16(7):e0254134. doi: 10.1371/journal.pone.0254134. eCollection 2021.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 21CT020be
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.