Blood Loss Measurement Using Electrical Impedance Tomography
Measurement of Blood Loss Using Electrical Impedance Tomography
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Electrical impedance tomography is a bedside method of ventilation monitoring. The bioimpedance of the tissue depends, among other things, on its blood content. The area of the chest and especially the lungs is a heavily perfused tissue, which also serves as one of the reservoirs of blood in case of blood loss. It is therefore possible that blood loss will be visible on chest bioimpedance relatively soon.
The study will be performed on voluntary blood donors. Blood loss of 450 mL will be caused by the collection of donated blood. During blood collection at the transfusion department, thoracic bioimpedance will be measured using electrical impedance tomography. The resulting signal change will then be analyzed to determine the possibility of detecting and measuring blood loss using electrical impedance tomography.
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Vaclav Ort, M.Eng.
- Phone Number: +420 731 577 649
- Email: ortvacla@fbmi.cvut.cz
Study Locations
-
-
-
Kladno, Czechia, 272 01
- Recruiting
- Czech Technical University, Faculty of Biomedical Engineering
-
Contact:
- Karel Roubik, PhD
- Phone Number: +420 603 479 901
- Email: roubik@fbmi.cvut.cz
-
Kladno, Czechia, 27201
- Recruiting
- Czech technical university in Prague, Facutly of biomedical engineering
-
Contact:
- Vaclav Ort, M.Eng
- Phone Number: +420731577649
- Email: ortvacla@fbmi.cvut.cz
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- voluntary blood donation
Exclusion Criteria:
- standard exclusion criteria for voluntary blood donation based on the transfusion station protocol
- standard exclusion criteria for electrical impedance tomography according to the manufacturer
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Voluntary blood donors
Voluntary blood donors undergoing standard blood donation while measuring electrical impedance of the chest .
|
During standard blood donation, donors' chest bioimpedance will be measured using electrical impedance tomography.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in chest electrical impedance due to blood loss.
Time Frame: Time frame of one voluntary blood donation process (15 min)
|
A change in the electrical impedance of the chest of a voluntary blood donor caused by a blood donation.
|
Time frame of one voluntary blood donation process (15 min)
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Vaclav Ort, M.Eng., Czech Technical University in Prague, Fac. of Biomedical Engineering
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 12229 (Company Internal)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.