Influence of Silicone Hydrogel Extended Contact Lens Wear on Corneal Sensitivity
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Daniela Nosch, PhD
- Phone Number: +41789120520
- Email: daniela.nosch@fhnw.ch
Study Locations
-
-
Solothurn
-
Olten, Solothurn, Switzerland, 4600
- Institute of Optometry
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- no contact lens wear three days before first visit
- corneal radius between 7.4 and 8.0; if corneal radius >8.0, corneal diameter must be at least 12 mm; if corneal radius < 7.4, corneal diameter must be < 12.0
- OSDI score no higher than 13 points
Exclusion Criteria:
- systemic disease that may have an influence ocular healtjh
- active ocular disease and no history of ocular surgery
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: extended contact lens wear
subjects wear silicone hydrogel contact lenses continuously for 7+/- 1 days - corneal sensitivity will be measured and compared at baseline versus after extended contact lens wear
|
silicone hydrogel contact lens
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
difference in corneal sensitivity threshold baseline and after 7 days of extended contact lens wear
Time Frame: 7+/-1 days
|
The difference in corneal sensitivity threshold baseline versus after 7 days of extended contact lens wear will be determined.
Corneal sensitivity measurement will take place with the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and will be recorded in mbar.
|
7+/-1 days
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
correlation between corneal sensitvity threshold and subjective symptoms
Time Frame: 7+/-1 days
|
correlation between corneal sensitvity threshold and subjective symptoms after 7 days of extended contact lens wear: corneal sensitivity threshold will be determinded with the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) and will be recorded in mbar.
Subjective Symptoms will be recorded with the CLEDQ8 questionnaire (specifically designed to assess contact lens comfort)
|
7+/-1 days
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Daniela Nosch, PhD, Institute of Optometry, FHNW
Publications and helpful links
General Publications
- Belmonte C, Acosta MC, Gallar J. Neural basis of sensation in intact and injured corneas. Exp Eye Res. 2004 Mar;78(3):513-25. doi: 10.1016/j.exer.2003.09.023.
- Morgan PB, Murphy PJ, Gifford KL, Gifford P, Golebiowski B, Johnson L, Makrynioti D, Moezzi AM, Moody K, Navascues-Cornago M, Schweizer H, Swiderska K, Young G, Willcox M. CLEAR - Effect of contact lens materials and designs on the anatomy and physiology of the eye. Cont Lens Anterior Eye. 2021 Apr;44(2):192-219. doi: 10.1016/j.clae.2021.02.006. Epub 2021 Mar 25.
- Muller LJ, Marfurt CF, Kruse F, Tervo TM. Corneal nerves: structure, contents and function. Exp Eye Res. 2003 May;76(5):521-42. doi: 10.1016/s0014-4835(03)00050-2. Erratum In: Exp Eye Res. 2003 Aug;77(2):253.
- Nosch DS, Oscity M, Steigmeier P, Kaser E, Loepfe M, Joos RE. Working principle and relevant physical properties of the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) evaluation. Ophthalmic Physiol Opt. 2022 May;42(3):609-618. doi: 10.1111/opo.12962. Epub 2022 Feb 14.
- Cheng KH, Leung SL, Hoekman HW, Beekhuis WH, Mulder PG, Geerards AJ, Kijlstra A. Incidence of contact-lens-associated microbial keratitis and its related morbidity. Lancet. 1999 Jul 17;354(9174):181-5. doi: 10.1016/S0140-6736(98)09385-4.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimate)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2022-D0011
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Cornea
-
NCT01220193CompletedCataract Surgery | Normal Cornea | Post Laser Refractive Surgery | Cornea Pathology
-
NCT04804592CompletedCornea | Sense Loss; Cornea
-
NCT03095235TerminatedKeratoconus | Cornea Ectasia
-
NCT07277348Not yet recruiting
-
NCT05377515CompletedCataract | Presbyopia | Irregular; Contour of Cornea
-
NCT05461469CompletedLimbal Stem-cell Deficiency | Cornea Disease | Eyes Dry Chronic | Chronic Conjunctivitis of Both Eyes | Eye Lesion | Eye Disease; Cataract | Eyes Dry Feeling of | Cornea Inflamed | Cornea; Injury, Abrasion | Cornea Infection
-
NCT01537393CompletedCornea Preservation Time | Endothelial Keratoplasty | Transplant Success | Endothelial Cell Density
Clinical Trials on silicone hydrogel contact lens
-
NCT03859440Unknown
-
NCT00363623CompletedMyopia | Hyperopia
-
NCT06716385Completed
-
NCT00346593Completed
-
NCT06716372Completed
-
NCT05745220Completed
-
NCT00708643Completed