Non-invasive Blood Pressure Measurement Using Samsung Smartwatch
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Veronika Rafl Huttova, MSc
- Phone Number: +420224355049
- Email: huttover@fbmi.cvut.cz
Study Contact Backup
- Name: Jakub Rafl, PhD
- Phone Number: +420224359931
- Email: rafl@fbmi.cvut.cz
Study Locations
-
-
-
Kladno, Czechia, 27201
- Faculty of biomedical Engineering, Czech Technical University in Prague
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- healthy volunteers
Exclusion Criteria:
- any acute illness
- pregnancy
- severe cardiovascular conditions
- severe asthma or other severe respiratory conditions
- diabetes
- hypotension or hypertension
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Blood pressure and heart rate measurement
Calm measurement of blood pressure and heart rate simultaneously by smartwatch and vital signs monitor.
Each participant will undergo this measurement a total of 6 times.
|
Simultaneous blood pressure and heart rate measurements at minutes 2 and 5.5 of the experiment.
Five minutes of physical activity, between times 7.5 min and 12.5 min of the experimental part.
Riding on a spinning ergometer with a standardized load of 1 W/kg.
Simultaneous blood pressure and heart rate measurements at times 15.5, 17, 20.5 and 22 minutes of the experimental part.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Similarity of blood pressure measurements from two devices
Time Frame: 1 hour
|
The agreement of systolic and diastolic blood pressure measurements of both monitoring devices will be evaluated.
|
1 hour
|
|
Similarity of heart rate measurements from two devices
Time Frame: 1 hour
|
The agreement of heart rate measurements of both monitoring devices will be evaluated.
|
1 hour
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Veronika Rafl Huttova, MSc, Czech Technical University in Prague
- Principal Investigator: Jakub Rafl, PhD, Czech Technical University in Prague
- Principal Investigator: Martin Rozanek, PhD, Czech Technical University in Prague
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- NIBPsmartwatch21
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.