Osseodensification Drills Versus Piezoelectric Surgery
Changes in Implant Stability Using Different Site Preparation Techniques: Osseodensification Drills Versus Piezoelectric Surgery. A Multicenter Randomized Controlled Clinical Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Impianti stability represents one of the most fundamental issue for implant success. Different techniques of implant site preparation are available such as twist drill, osteotome, piezosurgery and lastly, osseodensification. Due to their different approach an biological rationale, piezosurgery and osseodensification might show diverse impact on implant first and secondary stability, therefore the aim of the present study was the assessment of primary and secondary stability changes of values between implant sites prepared with piezoelectric bone surgery and with specific osseodensification drills.
Patients with bilateral single maxillary edentulism will randomly receive implant site preparation with piezoelectric approach or with osseodensification drills. standardized implants will be therefore inserted and primary stability will be assessed at the time of implant insertion and during the subsequent timepoints.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Parma, Italy, 43100
- Piezosurgery Academy
-
-
CS
-
Cassano allo Ionio, CS, Italy, 87011
- Hesire
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- bilateral single maxillary edentulism
Exclusion Criteria:
- smoking habit
- history of periodontal disease
- uncontrolled diabetes
- pregnancy or breastfeeding
- head and neck radiotherapy or chemotherapy
- bone antiresorptive therapy
- coagulopaties
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: 8 millimeter implants
implant insertion with piezo surgical osteotomy and with osseodensification drills
|
piezoelectric bone surgery osseodensification drills
Other Names:
|
|
Experimental: 10 millimeter implants
implant insertion with piezo surgical osteotomy and with osseodensification drills
|
piezoelectric bone surgery osseodensification drills
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
implant insertion torque
Time Frame: at implant insertion
|
insertion torque
|
at implant insertion
|
|
implant stability quotient
Time Frame: at implant insertion
|
resonance frequency
|
at implant insertion
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
implant secondary stability
Time Frame: 7 days after implant insertion
|
resonance frequency
|
7 days after implant insertion
|
|
implant secondary stability
Time Frame: 14 days after implant insertion
|
resonance frequency
|
14 days after implant insertion
|
|
implant secondary stability
Time Frame: 21 days after implant insertion
|
resonance frequency
|
21 days after implant insertion
|
|
implant secondary stability
Time Frame: 28 days after implant insertion
|
resonance frequency
|
28 days after implant insertion
|
|
implant secondary stability
Time Frame: 2 months after implant insertion
|
resonance frequency
|
2 months after implant insertion
|
|
implant secondary stability
Time Frame: 3 months after implant insertion
|
resonance frequency
|
3 months after implant insertion
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Director: Claudio Stacchi, Dr, International Piezoelectric surgery Academy
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- piezodensi
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.