NEURESCUE Device as an Adjunct to In-Hospital Cardiac Arrest (ARISE) (ARISE)
A Feasibility Study of the NEURESCUE Device as an Adjunct to In-Hospital Cardiac Arrest
The NEURESCUE device is the first intelligent catheter for aortic balloon occlusion, an emergency technique that supercharges blood flow to the heart and brain within one minute from deployment.
The catheter-based device is delivered via the femoral artery, temporarily inflating a soft balloon in the descending aorta to redirect blood flow towards the upper body.
The objective of this study is to investigate the feasibility of the NEURESCUE device as an adjunct to Advanced Cardiac Life Support (ACLS) in adults with cardiac arrest.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Habib Frost, M.D.
- Phone Number: +4553536760
- Email: habib.frost@neurescue.com
Study Locations
-
-
California
-
Long Beach, California, United States, 90806
- Long Beach Medical Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age ≥18 and ≤80 years
- CPR initiated within 7 min of presumed arrest
- 8 min of continuous ACLS without ROSC
Exclusion Criteria:
- Traumatic cardiac arrest
- Intraoperative cardiac arrest
- Known pregnancy
- Known terminal disease
- Known do-not-attempt-CPR order
- Subjects whose femoral arterial access site cannot accommodate an 8 Fr introducer sheath
- Subjects currently on mechanical circulatory support
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Treatment
The NEURESCUE device will be used as an adjunct to ACLS.
|
The balloon catheter is delivered via the femoral artery, temporarily inflating a soft balloon in the descending aorta to redirect blood flow towards the upper body.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Successful balloon inflation within 10 minutes from first vessel puncture
Time Frame: Assessed up to 10 min
|
Assessed up to 10 min
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Change in central blood pressure
Time Frame: Assessed up to 1 hour
|
Assessed up to 1 hour
|
|
|
Total ACLS time at initiation of the investigational procedure
Time Frame: Assessed up to 1 hour
|
Assessed up to 1 hour
|
|
|
Time from first vessel puncture to successful sheath insertion
Time Frame: Assessed up to 1 hour
|
Assessed up to 1 hour
|
|
|
Rate of occlusion success
Time Frame: Assessed up to 1 hour
|
Assessed up to 1 hour
|
|
|
Return of spontaneous circulation (ROSC)
Time Frame: Assessed up to 1 hour
|
The endpoint is dichotomous (yes/no) for each subject
|
Assessed up to 1 hour
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: David Shavelle, M.D., Long Beach Medical Center
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Safestudy3
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.