Safety and Tolerance of the Use of InnoCath AB® Hyper-compliant Balloon (HYPER)
Evaluation of the Safety and Tolerance of the Use of InnoCath AB® Hyper-compliant Balloon Catheters in Peripheral Arteries
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Berlin, Germany, 14129
- Klinik für Diagnostische und Interventionelle Radiologie Evangelisches Krankenhaus Hubertus
-
Berlin, Germany, 14193
- Klinik für Radiologie und Nuklearmedizin Martin-Luther-Krankenhaus
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- 18 years of age
- Patients with peripheral arterial occlusive disease and intended for endovascular therapy in the SFA and/or popliteal artery pars I/II
- Patients suitable for endovascular therapy in the SFA and/or popliteal artery pars I/II with a hyper-compliant balloon without further luminal widening
- Target vessels with a sufficient "runoff" to the foot with at least one vessel
- Rutherford classification 1-4 if physical and medicinal therapies have not been successful
Exclusion Criteria:
- Aneurysms at the site of inflation
- Application directly in the area of large vessel wall injuries with heavy bleeding
- Rutherford classification 5 and 6
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: InnoCath AB® Balloon
endovascular treatment of lesions in the superficial femoral artery (SFA) and/or popliteal artery pars I/II without further luminal widening, and/or for short-term interruption of blood flow with the InnoCath AB® hyper-compliant balloon cathe-ters (100 or 200 mm length)
|
endovascular treatment of lesions in the superficial femoral artery (SFA) and/or popliteal artery pars I/II without further luminal widening, and/or for short-term interruption of blood flow with the InnoCath AB® hyper-compliant balloon cathe-ters (100 or 200 mm length)
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Safety and tolerance
Time Frame: up to 30 days after intervention
|
Number of events, which are related to the medical device being tested
|
up to 30 days after intervention
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Procedural success
Time Frame: till the end of the procedure
|
defined as technical success (ability of the InnoCath AB® hyper-compliant bal-loon catheter to perform as intended, inflation of the device at the lesion site and retraction of the balloon catheter through the introductory sheath) in the ab-sence of vessel rupture, distal embolization, thrombosis, access complications, and major adverse cardiovascular events (cardiac death, myocardial infarction, stroke) as a consequence of the procedure and related to the study device till the end of the procedure
|
till the end of the procedure
|
|
Handling of the InnoCath AB® hyper-compliant balloon catheter
Time Frame: throughout the entirety of the procedure
|
The handling of the InnoCath AB® hyper-compliant balloon catheter will be evaluated by the investigator, who assesses various parameters using a scale from 0-2, where 0 describes the better outcome; e.g.
balloon deflation and withdrawal of balloon catheter: 0=easy, without any problems, 1=difficult, abnormal, 2=not possible.
|
throughout the entirety of the procedure
|
|
Device deficiencies of the InnoCath AB® hyper-compliant balloon catheter
Time Frame: throughout the entirety of the procedure
|
The device deficiencies of the InnoCath AB® hyper-compliant balloon catheter will be assessed by the investigator as free-text.
Device deficiencies means any inadequacy in the identity, quali-ty, durability, reliability, safety or performance of an investigational device, including malfunc-tion, use errors or inadequacy in information supplied by the manufacturer
|
throughout the entirety of the procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Michael Werk, Dr, Martin-Luther-Krankenhaus
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- InnoCathAB®_01
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Lesions in the Superficial Femoral Artery and/or Popliteal Artery Pars I/II
-
NCT06416644Active, not recruitingPeripheral Arterial Disease | Popliteal Artery Stenosis | Superficial Femoral Artery Occlusion | Popliteal Artery Occlusion | Lower Limb Ischemia | Superficial Femoral Artery Stenosis | Atherosclerosis of Femoral Artery | Chronic Limb Ischemia | Chronic Limb-Threatening Ischemia | Popliteal Arterial Stenosis
-
NCT00187811UnknownAtherosclerotic Narrowing of the Superficial Femoral Artery | Atherosclerotic Occlusion of the Superficial Femoral Artery
-
NCT06410313RecruitingPopliteal Artery Stenosis | Superficial Femoral Artery Stenosis
-
NCT01403077CompletedAtherosclerosis of Femoral Artery | Superficial Femoral Artery Lesions
-
NCT06734221RecruitingPeripheral Artery Disease | Superficial Femoral Artery Stenosis | Popliteal Artery Stenosis Above the Knee
-
NCT04588571RecruitingAtherosclerosis | Ischemia Limb | Superficial Femoral Artery Occlusion | Popliteal Artery Occlusion
-
NCT04590131RecruitingAtherosclerosis | Ischemia Limb | Superficial Femoral Artery Occlusion | Popliteal Artery Occlusion | Stent Complication
-
NCT01177033UnknownIntermittent Claudication | Complex Lesions of the Superficial Femoral Artery
-
NCT04583436RecruitingSuperficial Femoral Artery Occlusion | Popliteal Artery Occlusion | Atherosclerotic Ischemic Disease | Critical Limb Ischemia
-
NCT07359807Not yet recruitingSuperficial Femoral Artery Disease | Popliteal Artery Disease
Clinical Trials on InnoCath AB® hyper-compliant balloon catheter
-
NCT06924736Not yet recruitingCoronary Artery Disease
-
NCT00686647CompletedMyocardial Ischemia | Coronary Artery Disease
-
NCT07542938Not yet recruitingSymptomatic Intracranial Atherosclerotic Stenosis
-
NCT02468960UnknownCoronary Artery Disease | Stable Angina | Unstable Angina | Angina
-
NCT07159087Enrolling by invitation
-
NCT07492186Not yet recruitingInduction of Childbirth
-
NCT03902444RecruitingIntracranial Stenosis
-
NCT02408822Active, not recruitingDysfunction of Hemodialysis Vascular Access (Fistula and Graft)
-
NCT02813577TerminatedPopliteal Artery Stenosis | Popliteal Artery Occlusion | Femoral Artery Occlusion | Femoral Artery Stenosis