CARTO-Finder Guided Ablation Versus Multiscale Entropy Guided Ablation in Persistent Atrial Fibrillation
A Randomized Control Trial to Compare the Efficacy and Safety of CARTO-Finder-guided Ablation Plus Pulmonary Vein Isolation and Multiscale Entropy-guided Ablation Plus Pulmonary Vein Isolation in Patients With Persistent Atrial Fibrillation
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Anticipated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Xu Liu, M.D.
- Phone Number: 18017321689
- Email: heartlx@sina.com
Study Locations
-
-
-
Shanghai, China
- Shanghai Chest Hospital
-
Contact:
- Xu Liu, Dr.
- Phone Number: 18017321689
-
Principal Investigator:
- Xu Liu
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Aged 18 to 80 years old
- Persistent AF
- Nonresponse or intolerance to ≥1 antiarrhythmic drug
Exclusion Criteria:
- With uncontrolled congestive heart failure;
- Having significant valvular disease;
- Having moderate-to-severe pulmonary hypertension;
- With myocardial infarction or stroke within 6 months of screening;
- With Significant congenital heart disease;
- Ejection fraction was <40% measured by echocardiography;
- Allergic to contrast media;
- Contraindication to anticoagulation medications;
- Severe pulmonary disease e.g. restrictive pulmonary disease, chronic obstructive disease (COPD);
- Left atrial thrombus;
- Having any contraindication to right or left sided heart catheterization
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: CARTO-Finder-guided ablation plus PVI
Pulmonary vein circumferential isolation + + ablation of sites recognized by CARTO-Finder module as the core of rotors.
|
CARTO-Finder-guided ablation plus PVI
|
|
Experimental: Multiscale entropy-guided ablation plus PVI
Pulmonary vein circumferential isolation + ablation of sites recognized by multiscale entropy analysis as the core of rotors.
|
The multiscale entropy is calculated based on intracardiac electrical signals, higher multiscale entropy value indicates closer to the core of rotors which maintains the persistent atrial fibrillation.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Postoperative atrial fibrillation (AF)/atrial flutter (AFL)/atrial tachycardia (AT) recurrence rate
Time Frame: up to 24 months after enrollment
|
AF/AFL/AT recurrence is defined as presence of documented AF/AFL/AT episodes of 30 seconds or longer duration
|
up to 24 months after enrollment
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Postoperative AF recurrence rate
Time Frame: up to 24 months after enrollment
|
AF recurrence is defined as presence of documented AF episodes of 30 seconds or longer duration
|
up to 24 months after enrollment
|
|
Postoperative AFL/AT rate
Time Frame: up to 24 months after enrollment
|
Occurrence of AFL/AT is defined as presence of documented AFL/AT episodes of 30 seconds or longer duration
|
up to 24 months after enrollment
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Changes in the diameter of the left atrium
Time Frame: up to 24 months after enrollment
|
Changes in the diameter of the left atrium
|
up to 24 months after enrollment
|
|
Changes in the diameter of the left ventricular ejection fraction
Time Frame: up to 24 months after enrollment
|
Changes in the diameter of the left ventricular ejection fraction
|
up to 24 months after enrollment
|
|
Incidence of complications
Time Frame: up to 24 months after enrollment
|
death, atrio-esophageal fistula, cardiac tamponade/perforation, myocardial infarction, stroke/cerebrovascular accident, thromboembolism, diaphragmatic paralysis, pneumothorax, pleural effusion, heart block, pulmonary vein stenosis, pulmonary edema, left atrial thrombus, pericarditis and major vascular access complication or bleeding
|
up to 24 months after enrollment
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Study record dates
Study Major Dates
Study Start (Anticipated)
Study Start
Primary Completion (Anticipated)
Primary Completion
Study Completion (Anticipated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Find-AF
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.