Real-time Deflectable Guidewire in Neuro-interventions Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Guillaume Petit-Pierre, PhD
- Phone Number: +41 21 522 08 44
- Email: info@artiria-medical.com
Study Locations
-
-
-
Geneva, Switzerland
- Geneva University Hospital - HUG
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- >18 years of age
- Informed consent signed by patient
- Confirmed cerebral unruptured aneurysm treatable via transcatheter approach
Exclusion Criteria:
- Pregnancy or lactation
- Known disorder of vascular fragility with propensity to vascular injury (e.g., Ehlers-Danlos syndrome)
- Known prior vascular stenosis or dissection or injury to vessels intended to be catheterized during study procedures
- Acute phase myocardial infarction or uncontrolled cardiac arrhythmia
- Uncontrolled serum electrolyte imbalance
- Bleeding disorder which limits the use of antiplatelet and/or anticoagulant therapy
- Known contraindication to intravascular contrast material that cannot be adequately controlled with pre-medication
- Known hypersensitivity to Nickel
- Subjects currently enrolled in another investigational device or drug study that clinically interferes with the current study endpoints
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: SmartGUIDE (deflectable guidewire)
|
SmartGUIDE is a deflectable guidewire for use in interventional procedures in the neurovasculature and the peripheral vasculature.
It can be used to selectively introduce and position catheters and other interventional devices within the peripheral and neurovasculature.
The device is a steerable guidewire with a deflectable tip.
This allows adjusting the shape of the tip, dynamically, while the physician navigates the device in the patient's arterial and venous circulatory system.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Performance
Time Frame: During index procedure
|
Intra-procedural technical success defined as successful navigation of device to the vascular target vessel without need for shaping, removal or exchange.
|
During index procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Usability
Time Frame: During index procedure
|
Usability data (pushability, trackability, navigatability, shape retention, support, and proximal access complexity) collected through questionnaire completed by the physician.
Measured through a Likert scale from 1-5.
|
During index procedure
|
|
Procedural times
Time Frame: During index procedure
|
Procedural times (duration of tip reshaping, duration of access to target, duration of fluoroscopic exposition).
|
During index procedure
|
|
Safety - intra- and postprocedural
Time Frame: During index procedure and up to 48 hours post procedure
|
Adverse events, measured by the occurrence of adverse events
|
During index procedure and up to 48 hours post procedure
|
|
Device Deficiencies
Time Frame: During index procedure
|
Intraprocedural device deficiencies, measured by the occurrence of device deficiencies/malfunctions
|
During index procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Paolo Machi, Professor, Geneva University Hospital - HUG
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2022-01
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.