Effect of Bilateral Distalization of Upper First Molars in a Group of Patients After Extraction of Maxillary Second Molars
Effect of Bilateral Distalization of Upper First Molars in a Group of Patients After Extraction of Maxillary Second Molars Using Infra Zygomatic Mini Implants: A Prospective Clinical Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Cairo
-
New Cairo, Cairo, Egypt, 11835
- Future University in Egypt
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Female Patients with cervical vertebra maturation index (CVMI) 5 & 6.
- From quarter unit to 3\4-unit class II molar relationship.
- An overjet of an average 6mm.
- Full Set of permanent dentition except for the maxillary second molar.
- Favorable path of eruption for the maxillary third molar.
Exclusion Criteria:
- Medically compromised Patients.
- Patients under long term medications.
- Patients having sever periodontal disease.
- CVMI 3 or less
- Full unit class II cases
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Intra-oral Distalizing Appliance
Two infra zygomatic mini-implants will be placed Bands will be cemented to upper first molars. The inner bow (1.2mm) is a modified version of the inner part of a conventional face bow. Two hooks were soldered onto the inner bow distal to the lateral incisor teeth regions, and U loop at 1st premolar region, and bends acting as mesial stop will be bent in front of the maxillary first molars. Orthodontic force 300 mg per side Will be delivered by Niti closed coil spring which is attached from infra zygomatic mini screw to the hook soldered to the wire framework. |
The inner bow (1.2mm) is a modified version of the inner part of a conventional face bow.
Two hooks were soldered onto the inner bow distal to the lateral incisor teeth regions, and U loop at 1st premolar region, and bends acting as mesial stop will be bent in front of the maxillary first molars.
The anterior component of the inner bow is 3 mm free from the labial surface of anterior teeth
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
linear distalization of maxillary 1st molar.
Time Frame: Up until Class I Molar Relation (a maximum of 8 months regardless)
|
Efficiency of the proposed appliance to induce distalization of the upper 1st molar measured on Scanned dental casts as well as cone-beam computed tomography (CBCT) in millimetres.
|
Up until Class I Molar Relation (a maximum of 8 months regardless)
|
|
Rate of maxillary 1st molar Distalization in mm/ month.
Time Frame: Up until Class I Molar Relation (a maximum of 8 months regardless)
|
Efficiency of the proposed appliance to induce distalization of the upper 1st molar measured on Scanned dental casts with a monthly follow up in millimetres.
|
Up until Class I Molar Relation (a maximum of 8 months regardless)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Changes in Intermolar width in mm.
Time Frame: Up until Class I Molar Relation (a maximum of 8 months regardless)
|
Effect of the proposed appliance on the transverse Dental changes in the upper buccal segment through scanned dental cast in millimetres
|
Up until Class I Molar Relation (a maximum of 8 months regardless)
|
|
Changes of Molar inclination in degrees.
Time Frame: Up until Class I Molar Relation (a maximum of 8 months regardless)
|
Effect of the proposed appliance on the angulation of the first permanent molar through scanned dental cast and cone-beam computed tomography (CBCT) in degrees.
|
Up until Class I Molar Relation (a maximum of 8 months regardless)
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- FUE.REC(23)/11-2020
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
- ICF
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.