Evaluation of a Hearing Device for Transmitting Sound to the Inner Ear
Evaluation of a Sound Processor for a Transcutaneous System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Ann-Charlotte Persson
- Phone Number: 0046 70 960 92 16
- Email: ann-charlotte.l.persson@vgregion.se
Study Locations
-
-
-
Gothenburg, Sweden, 41663
- Habilitation & Health, Hearing organization
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Signed Informed Consent Form
- Adult subjects (18 years or older)
- Subjects implanted with an I1 implant
- Fluent in Swedish
Exclusion Criteria:
- Subjects who do not have the ability or are un-willing to follow investigational procedures/requirements, e.g., to complete questionnaires, according to investigator's discretion.
- Subject deemed unsuitable for any medical or other reason as judged by PI or medical responsible.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Sentio 1 sound processor
The sound processor picks up the sound and transfer it to the implant that convert the sound to vibrations that are transmitted to the inner ear.
|
Sound processor
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To Assess the Improvement of Hearing With the Sentio1 (PTA4)
Time Frame: 1 month
|
Functional gain with Sentio 1, i.e., the difference in dB between unaided and aided sound field thresholds, calculated on average for frequencies 500, 1000, 2000 and 4000 Hz (PTA4). In detail, for each patient, sound field thresholds are measured at the frequencies 500, 1000, 2000 and 4000 Hz for which a mean value is calculated and denoted as PTA4. The primary outcome measure is functional gain which is the difference in PTA4 measured unaided (without sound processor) versus aided condition (with sound processor). |
1 month
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
To Assess the Improvement of Hearing With the Sentio1
Time Frame: 1 month
|
Functional gain with Sentio 1, i.e., the difference in dB between unaided (without sound processor) and aided (with sound processor on) sound field thresholds, for all measured frequencies. In detail, for each patient, sound field thresholds are measured at the frequencies 250, 500, 1000, 2000, 3000, 4000, 6000 and 8000 Hz, with and without the sound processor on. |
1 month
|
|
Subjective Evaluation of Sound Processor Performance.
Time Frame: 1 month
|
Sentio 1 compared to previous sound processor.
Measured by the Speech, Spatial and Quality (SSQ) scale from 0-10 where 0 represents "Not at all" and 10 represents "Perfect". Higher scores mean a better outcome. For each of the scales the item outcomes are averaged. Fot the total score all items are averaged |
1 month
|
|
Subjective Sound Processor Preference
Time Frame: 1 month
|
Percentage (%) of subjects who prefer the Sentio 1 over current sound processor
|
1 month
|
|
To Assess the Degree to Which Sentio 1 Compensates for the BC Hearing Loss
Time Frame: 1 month
|
|
1 month
|
|
To Assess the Difference Between BC In-situ Thresholds Measured With Sentio 1 and Conventional Unmasked BC Audiometry.
Time Frame: 1 month
|
Difference in dB between Sentio 1 BC in situ thresholds and BC thresholds measured with conventional unmasked BC audiometry for the frequencies 500, 1000, 2000, 3000 and 4000 Hz. The BC in-situ threshold is a measure of the inner ear functionality with the device. This should correspond to the unmasked BC thresholds measured with conventional audiometry. The difference was calculated as the threshold value measured with Sentio 1 minus the threshold value measured with conventional audiometry. Negative values indicate that the thresholds measured with Sentio 1 were lower (better) compared to those measured with conventional audiometry. Conversely, positive values indicate that the thresholds measured with Sentio 1 were higher (worse) compared to conventional audiometry. It's expected that two measurements should be comparable to each with a difference of maximum +/-5 dB. |
1 month
|
|
Assess Safety With the Sentio 1 Sound Processor
Time Frame: 12 months
|
Tabulation of AEs occurred throughout the investigation and percentage of individuals with reported AEs.
|
12 months
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Ann-Charlotte Persson, Habilitation & Health, Hearing organization Södra Gubberogatan 6, 416 63 Göteborg, Sweden
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- BC114
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Conductive Hearing Loss
-
NCT04803279CompletedEar Diseases | Hearing Loss, Conductive | Hearing Loss Mixed | Hearing Disability | Conductive Hearing Loss | Conductive Hearing Loss, Bilateral | Conductive Hearing Loss, Unilateral
-
NCT07580287Not yet recruitingConductive Hearing Loss | Mixed Hearing Loss
-
NCT03374787CompletedConductive Hearing Loss | Mixed Hearing Loss
-
NCT06310278RecruitingConductive Hearing Loss, Middle Ear
-
NCT02438618CompletedConductive Hearing Loss | Unilateral Partial Deafness | Mixed Conductive-sensorineural Hearing Loss
-
NCT01264510WithdrawnConductive Hearing Loss | Unilateral Deafness | Mixed Hearing Loss
-
NCT06251817Enrolling by invitationNormal Hearing | Conductive Hearing Loss, Middle Ear
-
NCT02304692CompletedConductive Hearing Loss | Mixed Hearing Loss | Unilateral Partial Deafness
-
NCT05000931CompletedConductive Hearing Loss | Single-Sided Deafness | Mixed Hearing Loss
Clinical Trials on Sentio 1
-
NCT06976086RecruitingHearing Loss, Conductive | Hearing Loss, Mixed | Single Sided Deafness
-
NCT05166265Active, not recruitingHearing Loss, Conductive | Hearing Loss, Unilateral | Hearing Loss, Mixed
-
NCT03885011Completed
-
NCT01824485Completed
-
NCT05779046Completed
-
NCT01912885CompletedOveractive Bladder Syndrome
-
NCT00519714CompletedHypertriglyceridemia
-
NCT02185378CompletedObese Patients, One Lung Ventilation