iCare ST500 Clinical Trial
Clinical Validation of a Slit Lamp Mounted Rebound Tonometer
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Nova Scotia
-
Halifax, Nova Scotia, Canada, B3H 2Y9
- Nova Scotia Health/Dalhousie University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients at least 18 years old
Exclusion Criteria:
- Subjects with only one functional eye
- Subjects having poor or eccentric fixation in the study eye(s)
- High corneal astigmatism >3D in the study eye(s)
- Central corneal scarring
- History of prior incisional glaucoma surgery or corneal surgery, including corneal refractive laser surgery in the study eye(s)
- Microphthalmos
- Buphthalmos
- Contact lens use within one week of continuous wear and within one hour if lens is worn occasionally
- Dry eyes (clinically significant)
- Lid squeezers - blepharospasm
- Nystagmus
- Keratoconus
- Any other corneal or conjunctival pathology or infection relevant to this study
- Central corneal thickness greater than 600 μm or less than 500 μm in the study eye(s)
- Cataract Extraction within last 2 months in the study eye(s)
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: iCare ST500 vs GAT and iCare IC200
Measurement of intraocular pressure (IOP) with iCare ST500 compared to GAT and iCare IC200.
Measurements will be performed in three categories: Low IOP (7 to 16 mmHg), Medium IOP (>16 to <23 mmHg), or High IOP (≥23 mmHg).
|
Measurement of Intraocular Pressure (IOP)
Measurement of Intraocular Pressure (IOP)
Measurement of Intraocular Pressure (IOP)
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Demonstrate compliance with ANSI Z80.10:2014-Ophthalmics-Ophthalmic Instruments-Tonometers
Time Frame: Through study completion, an average of 4 months
|
Subjects will be distributed into Low IOP, Medium IOP, and High IOP groups based on Goldmann Applanation Tonometer measurements.
The iCare ST500 Tonometer measurements will be within +/-5.0 mmHg of the Goldmann Applanation Tonometer measurements in all groups.
|
Through study completion, an average of 4 months
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- TA04-185
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.