Concordance Between Central Blood PRessure dEvices In Nephrology Patients (CBP-REIN)
Concordance Between Central Blood PRessure dEvices In Nephrology Patients (CBP-REIN)
The most accurate way to determine intra-aortic BP is to obtain invasive measures by vascular catheterization, which is not possible to perform routinely during the regular follow-up of patients. However, in recent years, devices used to estimate central BP have been designed and approved for clinical use. These devices can determine aortic BP in a non-invasive way using various techniques and algorithms and offer a high degree of precision when compared to invasive measurements of intraaortic BP. On the other hand, certain characteristics specific to the different devices mean that the central BP values obtained may not be interchangeable. It is therefore important to determine the degree of agreement of central BP values obtained using commercially available devices.
This study aims to determine the degree of agreement between central BP measurements obtained using 4 devices commonly used to measure central blood pressure, i.e. Mobil-o-Graph NG (IEM, Germany), WatchBP Office (Microlife, Taiwan), Oscar 2 with SphygmoCor inside (SunTech, USA) and BP+ (Uscom, Australia). These four devices record the shape of the pulsatile wave and then derive the central BP using an algorithm. The main differences between these devices lie in this algorithm, or "transfer function,", which is unique to each and the calibration used. All use a brachial cuff to capture the pulse waveform and can easily be used in clinical practice.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Remi Goupil, MD MSc
- Phone Number: 1-514-338-2883
- Email: remi.goupil@umontreal.ca
Study Locations
-
-
Quebec
-
Montréal, Quebec, Canada, H4J1C5
- Hôpital du Sacré-Cœur de Montréal
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Age 18-80 years old
Exclusion Criteria:
- Ongoing atrial fibrillation
- Arm circumference incompatible with the blood pressure cuffs for all devices (<18 cm or > 50 cm)
- Incapacity to give consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Advanced CKD group
Patients with eGFR < 30 ml/min/1.73m2
not on dialysis
|
All participants will have three readings at 1-min interval after a 5-min seated rest with each device.
The order in which each device will be tested is randomized.
|
|
Experimental: Dialysis groups
Patients on hemodialysis or peritoneal dialysis
|
All participants will have three readings at 1-min interval after a 5-min seated rest with each device.
The order in which each device will be tested is randomized.
|
|
Experimental: Hypertension group
Patients with BP > 135/85 mmHg or taking any antihypertensive medication with normal kidney function (eGFR > 60 ml/min/1.73m2)
|
All participants will have three readings at 1-min interval after a 5-min seated rest with each device.
The order in which each device will be tested is randomized.
|
|
Active Comparator: Control group
Normotensive patients without any antihypertensive drugs or chronic kidney disease
|
All participants will have three readings at 1-min interval after a 5-min seated rest with each device.
The order in which each device will be tested is randomized.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Central SBP difference
Time Frame: at enrollment (time 0)
|
Differences in the central SBP measured by each device
|
at enrollment (time 0)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Brachial SBP difference
Time Frame: at enrollment (time 0)
|
Differences in the brachial cuff SBP measured by each device
|
at enrollment (time 0)
|
|
Central DBP difference
Time Frame: at enrollment (time 0)
|
Differences in the central DBP measured by each device
|
at enrollment (time 0)
|
|
Brachial DBP difference
Time Frame: at enrollment (time 0)
|
Differences in the brachial cuff DBP measured by each device
|
at enrollment (time 0)
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CBP-REIN
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.