Interstitial Assessment of Architectural Heterogeneity in Prostate Cancer Using a Fine Needle Photoacoustic Probe

November 6, 2026 updated by: University of Michigan Rogel Cancer Center

In this project, we will integrate the Photoacoustic (PA) technology into a prostate biopsy procedure through a fine needle probe. The needle probe will be in the shape of a biopsy needle and compatible with the needle insertion mechanism in the transrectal ultrasound (TRUS) probe. When inserted into the prostate, the fine needle PA probe will assess the histological information in its surrounding tissue without any tissue extraction. The needle probe has been tested in prostate tissue samples and whole human prostates ex vivo.

Study Overview

Status

Recruiting

Conditions

Intervention / Treatment

Detailed Description

14AUG2024- enrollment was increased to 50 subjects

Study Type

Observational

Enrollment (Estimated)

50

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

    • Michigan
      • Ann Arbor, Michigan, United States, 48109
        • Recruiting
        • University of Michigan Rogel Cancer Center
        • Contact:
        • Principal Investigator:
          • Guan Xu, Phd

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

40 years to 80 years (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

Male

Sampling Method

Non-Probability Sample

Study Population

Patients with planned prostate biopsy procedures will be recruited through U-M Urology Clinics

Description

Inclusion Criteria:

  • 1) Planned prostate biopsy as part of routine clinical care
  • 2) > 40 and <80 years old

Exclusion Criteria:

  • 1) Known history of bleeding disorders or
  • 2) Patients taking anticoagulants, no matter doses or washout time
  • 3) Known allergy to silicone material
  • 4) Unable to provide informed consent
  • 5) Either the surgeon or the patient do not think the patient will not be able to complete all parts of the study, the patient will be excluded
  • 6) Involved in other investigational studies.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Observational Models: OTHER
  • Time Perspectives: PROSPECTIVE

Cohorts and Interventions

Group / Cohort
Intervention / Treatment
Biopsy

Patients will be identified once prostate biopsies have been scheduled. Once enrolled on trial, patients will undergo standard biopsy procedure as per clinical care. During this biopsy, research measurements will be completed using the fine needle photoacoustic probe.

Fine Needle Photoacoustic Probe guided by the standard biopsy system without tissue core extraction

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Demonstration of reliable measurements
Time Frame: day 1

The primary aim of this study is to demonstrate that our fine needle PA probe can acquire reliable measurements of prostate glands. This will be indicated by a signal-to-noise ratio of the measurements that is larger than one.

We will calculate the signal to noise ratio of the signals as the peak-to-peak signal magnitude over the amplitude of the system background signal. The technical failure is that we will not be able to achieve measurements with signal-to-noise ratios larger than 1 in 10% of the measurements. We will have a futility analysis after first 5 patients are completed (thus 10 measurements). If of those 10 measurements, 2 have a SNR less 1, then the study will be stopped as it is unlikely to meet its 90% target.

day 1

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Determining the ability to observe differences between benign and cancerous regions
Time Frame: day 1

The secondary aim of this study is documenting our ability to observe differences between the PASA linear slope values derived from benign and cancerous regions, i.e., to detect the difference of 0.05 of 0.19, 0.17, 0.14, 0.20 dB/MHz between the means of the linear slopes in benign and cancerous regions at the wavelengths of 1220 nm, 1370 nm, 800 nm and 266 nm, respectively.

We will aim at differentiating the measurements in benign and cancerous regions at specific wavelengths. We have a null hypothesis for each wavelength that at this specific wavelength, our measurement cannot differentiate the benign and cancerous regions. We will test the hypothesis with paired t-tests.

day 1

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Collaborators

Investigators

  • Principal Investigator: Guan Xu, Phd, University of Michigan

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

October 16, 2023

Primary Completion (Estimated)

October 1, 2027

Study Completion (Estimated)

October 1, 2027

Study Registration Dates

First Submitted

April 27, 2023

First Submitted That Met QC Criteria

July 19, 2023

First Posted (Actual)

July 28, 2023

Study Record Updates

Last Update Posted (Actual)

November 9, 2026

Last Update Submitted That Met QC Criteria

November 6, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Keywords

Other Study ID Numbers

  • UMCC 2022.015
  • HUM00217834 (Other Identifier: University of Michigan)
  • R37CA222829 (U.S. NIH Grant/Contract)

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.