Guo's False Lumen Embolization : The First in Man Study of WeFlow-EndoSeal Aorta Vascular Plug System
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Wei Guo, Professor
- Phone Number: 13910758706
- Email: Pla301dml@vip.sina.com
Study Locations
-
-
Beijing
-
Beijing, Beijing, China
- Recruiting
- Chinese PLA Gencral Hosptial
-
Contact:
- Wei Guo
- Email: Pla301dml@vip.sina.com
-
-
Guangdong
-
Gaozhou, Guangdong, China
- Recruiting
- The People's Hospital of Gaozhou
-
Contact:
- Yu Cao, professor
-
Principal Investigator:
- Yu Cao, professor
-
-
Shanghai
-
Shanghai, Shanghai, China
- Recruiting
- Zhongshan Hospital Affiliated to Fudan University
-
Contact:
- Weiguo Fu, Professor
-
Principal Investigator:
- Weiguo Fu, professor
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients aged 18 to 80 years old, no gender limitation;
The patient was diagnosed with a dissecting aneurysm of the descending thoracic aorta after the repair of the main artery dissection, and the treatment indications were one of the following:
- Aortic dissection aneurysm diameter ≥ 5.5cm
- The diameter of descending thoracic aorta dissection increased rapidly ≥5 mm/ year
- Symptoms associated with dissection progression, such as chest and back pain
- The diameter of false lumen approximately 1 cm superiorly to the celiac trunk ≤40 mm
- Appropriate anatomical conditions were assessed by imaging to allow the adjustable bend conveyor to enter the pseudolumen through tears of the iliac artery, subrenal aorta, or renal artery levels.
- Those who can understand the purpose of the trial, voluntarily participate in the study, sign the informed consent form by themselves or their legal representative, and are willing to complete the follow-up according to the protocol requirements.
Exclusion Criteria:
- Aortic rupture;
- Continuous malperfusion of internal artery branches caused by dissection;
- Had previously received false lumen embolization;
- Proximal type I endoleak after aortic repair;
- Abdominal aortic dissection aneurysm diameter > 5 cm
- Infectious aortic disease, arteritis, Marfan syndrome (or other connective tissue diseases);
- Acute systemic infection;
- History of myocardial infarction, TIA or cerebral infarction within the past 3 months;
- Cardiac function Grade IV (NYHA rating) or LVEF < 30%;
- Hematological abnormalities: leukopenia (WBC < 3×10^9/L), anemia (Hb < 90 g/L); Coagulation dysfunction, thrombocytopenia (PLT count < 50×10^9/L);
- Renal insufficiency: serum creatinine > 150 umol/L (or 3.0 mg/dL) and/or advanced kidney disease requiring renal dialysis, as determined by the investigator after thorough analysis;
- Severe liver insufficiency: alanine aminotransferase (ALT) or aspartate aminotransferase (AST) exceeds the normal upper limit by 5 times; Serum total bilirubin (STB) exceeded the normal upper limit by 2 times;
- Allergic to contrast agents, anesthetics, plugs, and delivery materials;
- Pregnant, breastfeeding or cannot contraception during the trial period;
- Participated in clinical trials of other drugs or devices during the same period;
- Life expectancy is less than 12 months (such as advanced malignant tumors);
- Investigator judged that not suitable for interventional treatment.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: WeFlow-EndoSeal Aorta Vascular Plug System
|
The Aorta Vascular Plug System for false lumen is composed of a vascular plug system and an adjustable bend conveyor.
The plug system is composed of a patch and a conveying steel cable.
The plug is pre-installed on the conveying steel cable.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
No major adverse events within 30 days after operation.
Time Frame: 30 days after operation
|
Major adverse events within 30 days after operation refer to all-cause death, myocardial infarction, ischemic stroke, respiratory failure, renal failure, intestinal necrosis, paraplegia, and amputation within 30 days after operation.
Among them, renal failure refers to long-lasting dialysis, kidney transplantation, or other fatal results.
Intestinal necrosis is intestinal ischemia that requires bowel resection or other fatal consequences.
Severe lower limb ischemia refers to new severe limp or resting pain after surgery.
|
30 days after operation
|
|
All-cause mortality
Time Frame: 30 days, 6 months, and 12 months after operation
|
All-cause mortality includes cardiac mortality, non-cardiac mortality, and mortality from unknown causes.
|
30 days, 6 months, and 12 months after operation
|
|
Aortic dissection-related mortality,
Time Frame: 30 days, 6 months, and 12 months after operation
|
Refers to mortality caused by a ruptured aortic dissection or endovascular interventional treatment.
|
30 days, 6 months, and 12 months after operation
|
|
Serious adverse events.
Time Frame: 30 days, 6 months, and 12 months after operation
|
Refers to an event that occurs during the clinical trial that results in mortality or serious deterioration in patient health, including a fatal illness or injury, a permanent defect in body structure or body function, or an event that requires medical or surgical intervention to avoid one or more permanent defects in body structure or body function.
|
30 days, 6 months, and 12 months after operation
|
|
False lumen thrombosis of the descending thoracic aorta
Time Frame: 1 month, 6 months, and 12 months after operation
|
False lumen thrombosis of the descending thoracic aorta (no thrombosis, partial thrombosis, complete thrombosis) observed by postoperative CTA review.
|
1 month, 6 months, and 12 months after operation
|
|
Aortic dissection progression under control
Time Frame: 1 month, 6 months, and 12 months after operation
|
Aortic dissection progression under control is defined as maximum increase in the diameter of false lumen diameter in descending thoracic aorta was ≤ 5 mm when compared with preoperative aortic dissection as of postoperative CTA review.
|
1 month, 6 months, and 12 months after operation
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Endoseal V1.0
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.