Evaluation of Osseointegration Process of Dental Implants
Evaluation of Osseointegration Process of Implants With Different Length And Diameter By Different Methods
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Istanbul, Turkey, 34083
- Istanbul Medipol University, School of Dentistry
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Absence of any systemic disease
- being older than 20 years of age
- having partial tooth deficiency in the posterior region of the lower jaw (molar tooth deficiency)
- having an indication for dental implant-supported fixed prosthesis
- at least 6 months had elapsed since the last tooth extraction in the area to be implanted
- having a soft tissue thickness of at least 1.5 mm and adherent gingival width of at least 2 mm
- the existence of panoramic and dental volumetric tomography images of the area to be implanted
- the presence of a suitable recipient bone for implantation with dental implants of the desired length and diameter
- completion of periodontal treatment and provision of oral hygiene training; and acceptable existing gingival health and oral hygiene for implant application (periodontally healthy) in the oral examinations performed following periodontal treatment.
Exclusion Criteria:
- being in American Society of Anesthesiologists (ASA) Class 3 or 4 according to the ASA Physical Status Classification System
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Other: Patient selection
Patient selection criteria were as follows: absence of any systemic disease; not being in American Society of Anesthesiologists (ASA) Class 3 or 4 according to the ASA Physical Status Classification System (Doyle, 2017); being older than 20 years of age; the existence of panoramic and dental volumetric tomography images of the area to be implanted; the presence of a suitable recipient bone for implantation with dental implants of the desired length and diameter.
|
Patient selection were selected according to selected criteria.
|
|
Other: Dental Implant Application
Bredent SKY® dental implants were applied at a torque level of 30 N.cm as recommended by the manufacturer.
The surgery and all measurements were performed by the same surgeon.
|
dental implants were applied as recommended by the manufacturer.
|
|
Other: Osseointegration and periodontal measurements
Following the operations, the stability of the dental implants was measured at the 1st (T1), 4th (T4), and 12th (T12) weeks using Periotest (Periotest M, Modautal/Germany) and Osstell (Osstell AB-W&H, Sweden) devices.
In accordance with the manufacturers' recommendations, the final implant stability quotient (ISQ) and Periotest values were determined by calculating the average of three measurements per implant.
At the same time, periodontal index values of probing depth (PD-mm) and bleeding on probing (BOP-%) were recorded at the site of the dental implant at T4 and T12.
|
Following the operations, the stability of the dental implants was measured at the 1st (T1), 4th (T4), and 12th (T12) weeks using Periotest (Periotest M, Modautal/Germany) and Osstell (Osstell AB-W&H, Sweden) devices.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
RFA measurement
Time Frame: the 1st (T1), 4th (T4), and 12th (T12) weeks
|
two SmartPeg transducers were used on each implant, and three measurements were completed: therefore, total number of registers was six for each implant.
All assessment was carried out consecutively regardless register time or location.
Measurements were completed by one only experienced dentist with knowl- edge of the Osstell ISQ system for RFA assessment
|
the 1st (T1), 4th (T4), and 12th (T12) weeks
|
|
Periotest measurement
Time Frame: the 1st (T1), 4th (T4), and 12th (T12) weeks
|
The periotest device is placed in a horizontal position 0.6-2 mm away from the tooth surface and two PTVs (PTV1 and PTV2) were calculated with a time difference of 20 min.
During each measurement, the device delivers 16 impacts in 4 s to the object.
|
the 1st (T1), 4th (T4), and 12th (T12) weeks
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Pocket probing depth
Time Frame: he 1st (T1), 4th (T4), and 12th (T12) weeks
|
Measurement of the depth of a sulcus or periodontal pocket determined by measuring distance from a gingival margin to the base of the sulcus or pocket with a calibrated periodontal probe.
|
he 1st (T1), 4th (T4), and 12th (T12) weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Publications and helpful links
General Publications
- Branemark PI, Hansson BO, Adell R, Breine U, Lindstrom J, Hallen O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw. Experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1-132. No abstract available.
- Abrahamsson I, Linder E, Lang NP. Implant stability in relation to osseointegration: an experimental study in the Labrador dog. Clin Oral Implants Res. 2009 Mar;20(3):313-8. doi: 10.1111/j.1600-0501.2008.01646.x.
- Boronat Lopez A, Balaguer Martinez J, Lamas Pelayo J, Carrillo Garcia C, Penarrocha Diago M. Resonance frequency analysis of dental implant stability during the healing period. Med Oral Patol Oral Cir Bucal. 2008 Apr 1;13(4):E244-7.
Helpful Links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- 256
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.