Long-term Results of Two Surgical Methods for Scleral IOL Implantation and Fixation in Eyes Without Capsular Support: Yamane- Versus 4-flanged Technique (YAMPOINT)
This study is a comparison of the surgical techniques and postoperative outcome between the two intrascleral IOL fixation techniques: Yamane technique versus the 4-flanged technique.
The main objectives are postoperative lens tilt, duration of surgery, intra- and postoperative complication rates and scleral integrity around the flanges.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Markus Schranz, Md
- Phone Number: +4314040079690
- Email: markus.schranz@meduniwien.ac.at
Study Locations
-
-
-
Vienna, Austria, 1090
- Recruiting
- Medical University of Vienna
-
Contact:
- Markus Schranz, Md
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- - Necessity for IOL (re)fixation in the absence of capsular support
- willing to give informed consent and follow-up the duration of study
Exclusion Criteria:
- Anatomical or other contraindications for suture less IOL fixation, such as presence of a trabeculectomy bleb or scleromalacia
- active inflammatory diseases of the eye
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Yamane Arm
Scleral IOL fixation using the Yamane technique.
A 3 piece IOL (Kowa Avansee Preset) gets fixated in the sclera.
|
25gauge pars plana vitrectomy: to remove the vitreous if present
Removing if present a subluxated IOL from the anterior chamber or the vitreous cavity
Scleral IOL fixation using the Yamane technique.
A 3 piece IOL (Kowa Avansee Preset) gets fixated in the sclera using only its haptics, which are externalised 2.5mm behind the blue line.
The haptic ends are flanged using a thermo cautery to prevent slipping back in.
|
|
Active Comparator: "4-flanged" Arm
Scleral IOL fixation using the 4 flanged technique.
A 4 loop haptic IOL (Physiol Micropure 123) gets fixated in the sclera using 6.0 polypropylene suture
|
25gauge pars plana vitrectomy: to remove the vitreous if present
Removing if present a subluxated IOL from the anterior chamber or the vitreous cavity
Scleral IOL fixation using the 4 flanged technique.
A 4 loop haptic IOL (Physical Micropure 123) gets fixated in the sclera using one 6.0 polypropylene suture per 2 haptic loops, which are put trough the loops in a W shape.
The suture ends are externalised 2.5mm behind the blue line and its ends are flanged using a thermo cautery to prevent slipping back in.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
IOL tilt
Time Frame: 3 years
|
The postoperative intra ocular lens tilt in degree measured by an anterior segment optical coherence tomography device (Casia 2, Tommy, Japan)
|
3 years
|
|
IOL decentration
Time Frame: 3 years
|
The postoperative intra ocular lens decentration in millimetres measured by an anterior segment optical coherence tomography device (Casia 2, Tommy, Japan)
|
3 years
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Best corrected visual outcome
Time Frame: 12 weeks
|
The achieved best corrected visual (in Snellen) outcome after Intraocular lens implantation
|
12 weeks
|
|
Flange erosion and intrusion
Time Frame: 3 years
|
Risks of flange erosion trough the conjuctiva or intrusion through the sclera over the investigated time period
|
3 years
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- Y4P0923
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.