Acute Effect of Whole Body Vibration on Reaction Speed and Proprioception
Acute Effect of Whole Body Vibration on Reaction Speed and Proprioception in the Upper Extremity in Healthy Subjects
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Şahinbey
-
Gaziantep, Şahinbey, Turkey, 27000
- Gaziantep Islamic Science and Technology University
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Healthy individuals between the ages of 18-25
- Those who do not have any orthopedic problems in the upper extremity
- Individuals without any neurological problems
- Those who volunteer to participate in the study
Exclusion Criteria:
- Those who have vertigo
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Whole body vibration
A total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest.
|
A total of 5 sets of vibration will be given at 30 Hz, 2 mm amplitude, 1 minute of application and 1 minute of rest.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Nelson Hand Reaction Test
Time Frame: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
|
The participant is asked to sit in the chair with the forearm and hand comfortably resting on the table.
The tips of the thumb and index finger are positioned 8-10 cm away from the table, with the tops of the thumb and index finger parallel to each other.
The tester asks the individual to hold the ruler between his thumb and index finger.
At the same time, the patient is asked to look directly at the middle point of the ruler while holding it between his fingers.
As soon as the ruler is released, the person is told to catch the ruler with his thumb and forefinger.
The ruler is left and the numerical value on the upper edge of the subject's thumb, where the subject grasps the ruler, is read and recorded.
|
All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
|
|
Reaction Rate Evaluation with Sway Medical Smartphone Application
Time Frame: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
|
The person will sit comfortably on a chair and hold the smartphone with the thumbs on both sides.
When the orange screen appears, the phone should quickly rotate the screen in the desired direction.
Once you will do the test to learn the application.
Then, the application is made three times and the reaction rate is calculated by taking the average time of these three applications.
|
All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
|
|
Upper extremity proprioception measurement
Time Frame: All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
|
Elbow flexion, shoulder flexion and abduction 30 and 60 degree angles were measured with a digital goniometer.
The elbow and shoulder positions were brought to the desired angle and they were asked to return to the same angle.
The angle of deviation was recorded.
|
All measurements take 30 minutes for each individual, before and immediately after the application on the same day.
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Çağtay MADEN, Gaziantep Islamic Science and Technology University
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 2023/266
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.