Effect of Different Drilling Techniques on Primary Stability and Marginal Bone Loss of Extra Short Implants
The Effect of Low Speed Drilling Without Irrigation Versus Conventional Drilling With Irrigation in Extra Short Implants on Primary Stability and Marginal Bone Loss
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- There must be toothless space in the maxillary and mandibular posterior region (distal part of the canine in each quadrant).
- The edentulous space should not require additional bone grafting.
- Bleeding areas on probing should be less than 10%
- There should be no pathological periodontal pockets
- Patients who do not smoke or smoke less than 10 cigarettes
- There should be no bruxism
- At least 6 months must have passed since the last tooth extracted from the toothless space where the implant is planned.
- There should be no diabetes.
Exclusion Criteria:
- Having psychological problems
- Smoking more than 10 cigarettes
- Alcohol and drug use
- Pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Low Speed Drilling Without Irrigation
|
It is performed to reconstruct lost teeth.
These are surgical procedures performed to place dental implants in the jaw bones.
To prepare the implant socket, drilling is performed at a speed of 50 rpm without serum irrigation.
|
|
Active Comparator: Conventional Drilling with Irrigation
|
It is performed to reconstruct lost teeth.
These are surgical procedures performed to place dental implants in the jaw bones.
To prepare the implant socket, drilling is performed with serum irrigation at a speed of 800 rpm.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of the status of osseointegration
Time Frame: Three months after the implant is placed in the bone. At the end of three months
|
Fusion of the dental implant with the bone at the microscopic level.
Osseointegration will be evaluated as successful or unsuccessful.
Successful osseointegration is defined by no mobility in the implant, no radiolucency around the implant on radiography, and no pain in the implant.
Otherwise, the osseointegration of the implant is considered unsuccessful.
|
Three months after the implant is placed in the bone. At the end of three months
|
|
Marginal bone lose
Time Frame: Three months after the implant is placed in the bone. At the end of three months
|
It defines the change in the marginal bone level in the neck area of the implant.
It is determined by radiographic examination.
The initial radiograph is compared with the radiograph at the end of three months.
In measurements where the implant platform is the reference point, bone level changes are calculated in mm.
|
Three months after the implant is placed in the bone. At the end of three months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Insertion Torque value
Time Frame: Surgical stage where the implant is placed
|
It is the amount of compression of the implant when screwed into the bone.
The value detected by the electronic device that screws the implant into the bone cavity during screwing.
It is expressed in Newtons.
|
Surgical stage where the implant is placed
|
|
Implant Stability Quotient (ISQ Value)
Time Frame: 1- Surgical stage where the implant is placed; 2- Three months after the implant is placed in the bone. At the end of three months
|
The value obtained by the resonance frequency analysis (RFA) device used to measure the primary stability of dental implants.
The RFA technique is based on continual excitation of the implant through dynamic vibration analysis.
A transducer is connected to an implant, which is excited over a range of sound frequencies with subsequent measurement of the vibratory oscillation of the implant.
It is a non-invasive technique.
|
1- Surgical stage where the implant is placed; 2- Three months after the implant is placed in the bone. At the end of three months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- EUDF-OKUMUS-001
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.