Validation of a Magnetic Sensor in Arterial Flow Recording, Compared With the Reference Method, at Various Peripheral Arterial Sites (COMADO)
Validation Study of a Magnetic Sensor in Arterial Flow Recording, Compared With the Reference Method (Echodoppler), at Various Peripheral Arterial Sites
The measurement of magnetic fields emitted by cardiac activity has already been studied in magneto-cardiography. To date, however, this technology has never been evaluated in the peripheral circulation.
The magnetic susceptibility of iron in the circulating blood and the ionic currents in the blood stream generate a very weak induced magnetic current, which can be detected by the micro-sensor of the prototype investigators wish to study.
Proving the validity of this prototype would make it a new diagnostic and even prognostic tool, non-invasive, less costly and more accessible than Doppler for screening peripheral arterial disease.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Gudrun Boge, MD
- Phone Number: +33467336279
- Email: g-boge@chu-montpellier.fr
Study Locations
-
-
-
Montpellier, France
- Recruiting
- University Hospital Center
-
Contact:
- Gudrun BOGE, MD
- Phone Number: 33 467336279
- Email: g-boge@chu-montpellier.fr
-
Principal Investigator:
- Gudrun BOGE
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients hospitalized in the Heart-Lung Unit of the Montpellier University Hospital, for any reason whatsoever
- Patient with lower extremity artery disease (LEAD) (stage 1 to 4 according to Leriche and Fontaine) or not (absence of LEAD)
- Age ≥ 18 years
Exclusion Criteria:
- Patient with a metal implant in the vicinity of the device's area of use
- Patient requiring additional hygiene precautions
- Subject not affiliated to a social security scheme or not benefiting from such a scheme.
- Pregnant or breast-feeding woman, patient unable to give consent, protected adult, vulnerable persons
- Subject deprived of liberty by judicial or administrative decision
- Patient refusing to give consent
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Magnetic sensor
The CapMagic device is a small magnetic sensor, whose technology is derived from magnetocardiography, with a very weak field identical to that of a refrigerator magnet, which is placed on the foot or toe to record curves reflecting the state of the arterial network.
It does not require direct skin contact.
|
Evaluation by magnetic sensor on arm and leg
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Correlation of the two curve amplitudes (y) versus time (x) between the signal recording obtained by the CapMagic prototype on the radial artery and the pulsed echo-Doppler recording on the radial artery
Time Frame: On day 1
|
Correlation of the two curve amplitudes (y) versus time (x) between the signal recording obtained by the CapMagic prototype on the radial artery and the pulsed echo-Doppler recording on the radial artery, in adult patients with or without AOMI in hospital. The result is expressed by a Spearman correlation coefficient ranging from -1 to 1, with 0 corresponding to no correlation and 1 corresponding to a perfect positive correlation |
On day 1
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Correlations of the two curve amplitudes (y) versus time (x) between the signal recording obtained by the CapMagic prototype and the pulsed echo-Doppler recording, measured on the plantar artery on one side and on the pulpal artery on the other
Time Frame: On day 1
|
Correlations of the two curve amplitudes (y) versus time (x) between the signal recording obtained by the CapMagic prototype and the pulsed echo-Doppler recording, measured on the plantar artery on one side and on the pulpal artery on the other, in adult patients with or without LEAD in hospital. The result is expressed by a Spearman correlation coefficient ranging from -1 to 1, with 0 corresponding to no correlation and 1 corresponding to a perfect positive correlation |
On day 1
|
|
Correlation of the Pulsatility index (or Gosling Pulsatility index) between the signal recording obtained by the CapMagic prototype and the pulsed echo-Doppler recording
Time Frame: On day 1
|
IP=P/M where P=maximum amplitude of the trace (from highest positive value, i.e. peak systolic, to lowest value) and M=average circulatory velocity, averaged over the entire cardiac cycle.
Calculated from the Doppler or CapMagic curves.
|
On day 1
|
|
Correlation of the Systolic rise time (SRT) between the signal recording obtained by the CapMagic prototype and the pulsed echo-Doppler recording
Time Frame: On day 1
|
Systolic rise time (SRT), (ms) : the time between the foot and the peak of the pulse wave.
Calculated from the Doppler or CapMagic curves.
|
On day 1
|
|
Correlation of the Systolic peak between the signal recording obtained by the CapMagic prototype and the pulsed echo-Doppler recording
Time Frame: On day 1
|
Systolic peak, Measured in cm/s or mV: Peak height in systole.
Calculated from the Doppler or CapMagic curves.
|
On day 1
|
|
Correlation of Presence of critical ischemia measured by the CapMagic prototype and the pulsed echo-Doppler recording
Time Frame: On day 1
|
critical ischemia is defined by systolic pressure at toe < 30 mmHg or ankle < 50mmHg, or diagnosis of critical ischemia retained by the team in the impossibility of obtaining pressure measurements
|
On day 1
|
|
Correlation of the maximum acceleration of systolic rise between the signal recording obtained by the CapMagic prototype and the pulsed echo-Doppler recording
Time Frame: On day 1
|
The maximum acceleration of systolic rise (cm/s2) calculated from the Doppler or CapMagic curves.
|
On day 1
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- RECHMPL22_0391
- 2023-A01784-41 (Registry Identifier: ID-RCB)
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Lower Extremity Artery Disease
-
NCT01136811TerminatedLower Extremity Occlusive Disease
-
NCT05689190TerminatedLower Extremity Arterial Disease
-
NCT03643978CompletedUpper Extremity Dysfunction | Lower Extremity Problem
-
NCT01698671UnknownAortic Aneurysm, Abdominal | Occlusive Disease of Artery of Lower Extremity
-
NCT01417208WithdrawnLower Extremity Diabetic Leg Wounds | Lower Extremity Venous Leg Wounds | Lower Extremity Mixed Aetiology Leg Wounds
-
NCT06371209Enrolling by invitationLower Extremity Amputation | Trans-Tibial Amputation | Traumatic Lower Extremity Amputation | Agonist-Antagonist Myoneural Interface
-
NCT07629180Not yet recruitingLower Extremity Fractures
-
NCT07603531Not yet recruiting
-
NCT07333508Not yet recruitingLower Extremity Surgery
-
NCT06710119RecruitingLower Extremity Injuries
Clinical Trials on Evaluation by magnetic sensor
-
NCT07419087Not yet recruitingStroke (CVA) or TIA | Stroke (CVA) or Transient Ischemic Attack
-
NCT05913297Recruiting
-
NCT01691443Terminated
-
NCT03118063CompletedLow Back Pain | Spinal Injuries
-
NCT03399149CompletedRespiratory Insufficiency | Hematologic Malignancy
-
NCT02341066UnknownRheumatoid Arthritis | Coronary Heart Disease
-
NCT05928260Recruiting
-
NCT05019313Active, not recruitingCOVID-19 Pneumonia | Diaphragm Disease
-
NCT01167413UnknownFibromyalgia | Ankylosing Spondylitis