X-BS Ortho Bone Graft Study
Randomised Investigation of the Osteoconductive Performance and Safety of FDBS Bone Graft, With Contextual Reference to IBS, in the Filling of Orthopaedic Bone Defects.
Randomised investigation of the osteoconductive performance and safety of CE-marked FDBS bone graft (GraftR3®), with contextual reference to CE-marked IBS (MBCP® Putty), in the filling of orthopaedic bone defects.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The primary purpose of this study is to collect clinical investigation data on the performance and safety of the CE-marked FDBS bone graft (GraftR3®) for the reconstruction of bony voids or bone gaps, in orthopaedic applications that are not intrinsic to the stability of the bone structure. It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue.
The study is sponsored by Advanced Medical Solutions (Nantes) and will provide essential clinical evidence to support the clinical evaluation of FDBS (GraftR3®).
For contextual interpretation, a reference arm including IBS (MBCP® Putty), a CE-marked bone substitute with established conformity to the relevant essential requirements, has been incorporated. This will allow descriptive comparison with a marketed product while maintaining the primary focus on the CE-marked device FDBS.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Susan Clark
- Phone Number: 01606863500
- Email: susan.clark@admedsol.com
Study Contact Backup
- Name: Loïc Limon-Duparcmeur
- Phone Number: 01606863500
- Email: loiclimonduparcmeur@admedsol.com
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
-
Patient is male or female, 18 - 85 years old;
-
Patient is willing and able to give written informed consent;
-
Patient is able to comply with a prior medical examination;
-
Patient is or has been scheduled for a surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone void in one of the following anatomical locations either after traumatic injury or elective surgical reconstruction:
- Proximal humerus ▪ Distal radius
- Distal femur ▪ Proximal tibia ▪ Distal tibia
-
Patient is willing and able to comply with the study procedures during surgery and the post-surgical follow up period, up to 12 months.
Exclusion Criteria:
- Patient has had an infection in the same extremity within last 24 months;
- Patient has bone necrosis either after traumatic injury or elective surgical reconstruction at the surgical site;
- Patient has cellulitis;
- Patient has granuloma or non-curetted cyst;
- Patient has a current or previous diagnosis of osteomyelitis;
- Patient has a clinically significant degenerative bone disease;
- Patient has an history of uncontrolled diabetes;
- Patient is alcoholic and/or heavy smoker (> 20 cigarettes per day);
- Patient has a congenital or acquired immunodeficiency;
- Patient has severe bone loss (≥ 40cm3);
- Patient is on long-term steroidal therapy or treatment acting on the calcium or phosphorus metabolism;
- Patient is or has been scheduled for surgery that would involve intra-articular implantation of the study device;
- Patient who has or had an uncontained bone void (cavity) created as a result of trauma injury or surgically created;
- Patient was exposed to any radiation (e.g. X-Rays, handling of radiolabelled materials) other than the normal background radiation within the 12 months before the screening visit;
- Patient is pregnant or breastfeeding;
- Patient who is an employee at the study site;
- Patient is known to be non-compliant with medical treatment or follow-up
- Patient has any significant or unstable medical/psychiatric condition that, in the opinion of the Investigator, would interfere with their ability to participate in the study;
- Patient is currently enrolled or planning to enrol in another clinical study or treatment with another investigational drug/device that may interfere with the assessments, visits or outcomes of this study.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: FDBS (GraftR3®)
The CE-marked device FDBS (GraftR3®) is a powder that presents an interconnected network that enables the colonization of bone cells and biological fluid uniformly within the matrix required for the biological exchanges particularly for bone ingrowth. It is intended for the reconstruction of bony voids or bone gaps in orthopaedic applications that are not intrinsic to the stability of the bone structure. It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue. The clinical investigation is designed to generate data on the performance and safety of FDBS in orthopaedic trauma surgery. |
Use of FDBS (GraftR3®) in surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone defect in one of the following anatomical locations: Proximal humerus, Distal radius, Distal femur, Proximal tibia, Distal tibia. |
|
Active Comparator: IBS (MBCP® Putty)
The CE-marked device IBS (MBCP® Putty) is an injectable bone substitute to fill and reconstruct bone voids or bone gaps of the skeletal system (e.g. extremities, spine and pelvis). It acts as a bone void filler by occupying the defect and supporting bone ingrowth from the surrounding viable tissue. For contextual interpretation, the study will include patients treated with this technology, as published data remain limited for certain indications such as surgically created bone defects (e.g. post cyst removal) or bone gaps due to traumatic injury |
Use of IBS (MBCP® Putty) in surgical procedure to correct epiphyso-metaphyseal and/or metaphyso-diaphyseal bone defect in one of the following anatomical locations: Proximal humerus, Distal radius, Distal femur, Proximal tibia, Distal tibia. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of performance and safety of FDBS and IBS in the reconstruction of bone voids in the extremities
Time Frame: At 12 months post-surgery
|
Achievement of successful bone integration (without occurrence of Major Adverse Events) through radiological evaluation within 12 months by assessing interdigitation in 3 out of 4 anatomical planes (anterior/posterior/lateral/medial) |
At 12 months post-surgery
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Evaluation of device-related Adverse Events associated with FDBS and IBS in the reconstruction of bone voids in the extremities
Time Frame: Within 12 months post-surgery
|
Incidence of device related Adverse Events |
Within 12 months post-surgery
|
|
Functional evaluation after use of FDBS and IBS in the reconstruction of bone voids in the upper extremities
Time Frame: Within 12 months post-surgery
|
Functional mobility restoration by scoring patient's physical disability and symptoms through QuickDASH outcome measure |
Within 12 months post-surgery
|
|
Functional evaluation after use of FDBS and IBS in the reconstruction of bone voids in the lower extremities
Time Frame: Within 12 months post-surgery
|
Functional mobility restoration by scoring patient's physical disability and symptoms through LEFS outcome measure |
Within 12 months post-surgery
|
|
Evaluation of subject's pain after use of FDBS and IBS in the reconstruction of bone voids in the extremities
Time Frame: Within 12 months post-surgery
|
Patient's pain intensity at trauma/surgical site 0 = no pain; 10 = worst pain imagineable |
Within 12 months post-surgery
|
|
Evaluation of usability of FDBS and IBS in the reconstruction of bone voids in the extremities
Time Frame: Within 12 months post-surgery
|
Clinician satisfaction with use of FDBS and IBS as per IFU |
Within 12 months post-surgery
|
|
Evaluation of the difference in performance of FDBS versus IBS in the reconstruction of bone defects in the extremities
Time Frame: At 12 months post-surgery
|
Difference between FDBS and IBS in successful rates of bone integration through radiological evaluation at 12 months |
At 12 months post-surgery
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Peter Giannoudis, Leeds General Infirmary, Great George Street Leeds LS1 3EX, United Kingdom
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- STD-030-001
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.