Conduction System Vs Surgical Left Ventricular Epicardial Pacing For Coronary Sinus Lead Failure
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Cardiac resynchronization therapy with defibrillator(CRT-D) improves quality of life, functionality, and even mortality for select patients with severe heart failure with reduced ejection fraction (HFrEF). It traditionally consists of three leads placed endovascularly into the right atrium, right ventricle, and left ventricle (LV) [typically placed into the CS], known as biventricular pacing resynchronization (BVP-CRT), respectively, from which electrical stimulation enables improved cardiac synchrony. Nonetheless, the placement of a CRT-D is not without risks. Lead-related complication is high and CRT-D implantation fails in up to 30% of patients due to lead placement alone.
Epicardial lead placement and CSP have been deemed viable alternatives to CRT-D. It has even been shown to be options in patients that fail conventional BVP-CRT. This is primarily due to increased accuracy, decreased complications, and even durability. However, guidelines for decision between a transthoracic approach and CSP is unclear, even more so after lead failure. Instead, this decision is currently individualized to the patient. There is a lack of prospective and head-to-head data between the two, and this study is aimed to compare transthoracic LV epicardial lead placement and CSP in patients with lead failure after BVP-CRT.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Donita Atkins
- Phone Number: 816-651-1969
- Email: datkins@kchrf.com
Study Locations
-
-
Kansas
-
Overland Park, Kansas, United States, 66211
- Recruiting
- Kansas City Heart Rhythm Institute
-
Contact:
- Donita Atkins
- Phone Number: 816-651-1969
- Email: datkins@kchrf.com
-
Principal Investigator:
- Naga Venkata K. Pothineni, MD
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- All patients older than 18 years of age
- Patients with HFrEF that underwent BVP-CRT
- Experienced CS lead failure, whether initial or recurrent, subsequently replaced with transthoracic epicardial lead placement or CSP
- Underwent Medtronic, Boston Scientific, or Abbott lead placement
Exclusion Criteria:
- Patients younger than 18 years of age
- Transthoracic epicardial lead placement or CSP performed as the initial approach or for other reasons than lead replacement
- Those for which CRT no longer provides symptom relief or mortality benefit.
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Conduction System Pacing
Subjects who had lead placement via conduction system pacing approach
|
Coronary Sinus Lead Revision
|
|
Epicardial Lead Placement
Subjects who had lead placement via transthoracic, epicardial approach
|
Coronary Sinus Lead Revision
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Need for lead revision
Time Frame: Procedure Day
|
Compare the need for lead revision between conduction system pacing (CSP) and transthoracic left ventricular (LV) epicardial pacing approach
|
Procedure Day
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Electrocardiography characteristics - QRS Interval
Time Frame: Procedure Day
|
Compare electrocardiography characteristics - QRS Interval measured in seconds between conduction system pacing (CSP) and transthoracic left ventricular (LV) epicardial pacing approach
|
Procedure Day
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Naga Venkata K. Pothineni, Kansas City Heart Rhythm Institute
Publications and helpful links
General Publications
- Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, Kocovic DZ, Packer M, Clavell AL, Hayes DL, Ellestad M, Trupp RJ, Underwood J, Pickering F, Truex C, McAtee P, Messenger J; MIRACLE Study Group. Multicenter InSync Randomized Clinical Evaluation. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002 Jun 13;346(24):1845-53. doi: 10.1056/NEJMoa013168.
- Daubert C, Behar N, Martins RP, Mabo P, Leclercq C. Avoiding non-responders to cardiac resynchronization therapy: a practical guide. Eur Heart J. 2017 May 14;38(19):1463-1472. doi: 10.1093/eurheartj/ehw270.
- Alonso C, Leclercq C, d'Allonnes FR, Pavin D, Victor F, Mabo P, Daubert JC. Six year experience of transvenous left ventricular lead implantation for permanent biventricular pacing in patients with advanced heart failure: technical aspects. Heart. 2001 Oct;86(4):405-10. doi: 10.1136/heart.86.4.405.
- Sharma PS, Vijayaraman P. Conduction System Pacing for Cardiac Resynchronisation. Arrhythm Electrophysiol Rev. 2021 Apr;10(1):51-58. doi: 10.15420/aer.2020.45.
- Wu S, Su L, Vijayaraman P, Zheng R, Cai M, Xu L, Shi R, Huang Z, Whinnett ZI, Huang W. Left Bundle Branch Pacing for Cardiac Resynchronization Therapy: Nonrandomized On-Treatment Comparison With His Bundle Pacing and Biventricular Pacing. Can J Cardiol. 2021 Feb;37(2):319-328. doi: 10.1016/j.cjca.2020.04.037. Epub 2020 May 7.
- Butter C, Georgi C, Stockburger M. Optimal CRT Implantation-Where and How To Place the Left-Ventricular Lead? Curr Heart Fail Rep. 2021 Oct;18(5):329-344. doi: 10.1007/s11897-021-00528-9. Epub 2021 Sep 8.
- Pothineni NVK, Gondi S, Cherian T, Kovelamudi S, Schaller RD, Lakkireddy D, Gopinathannair R, Deshmukh A. Complications of Cardiac Resynchronization Therapy: Comparison of Safety Outcomes from Real-world Studies and Clinical Trials. J Innov Card Rhythm Manag. 2022 Aug 15;13(8):5121-5125. doi: 10.19102/icrm.2022.130805. eCollection 2022 Aug.
- Ahsan SY, Saberwal B, Lambiase PD, Chaubey S, Segal OR, Gopalamurugan AB, McCready J, Rogers DP, Lowe MD, Chow AW. An 8-year single-centre experience of cardiac resynchronisation therapy: procedural success, early and late complications, and left ventricular lead performance. Europace. 2013 May;15(5):711-7. doi: 10.1093/europace/eus401. Epub 2013 Jan 12.
- Navia JL, Atik FA, Grimm RA, Garcia M, Vega PR, Myhre U, Starling RC, Wilkoff BL, Martin D, Houghtaling PL, Blackstone EH, Cosgrove DM. Minimally invasive left ventricular epicardial lead placement: surgical techniques for heart failure resynchronization therapy. Ann Thorac Surg. 2005 May;79(5):1536-44; discussion 1536-44. doi: 10.1016/j.athoracsur.2004.10.041.
- Chen X, Ye Y, Wang Z, Jin Q, Qiu Z, Wang J, Qin S, Bai J, Wang W, Liang Y, Chen H, Sheng X, Gao F, Zhao X, Fu G, Ellenbogen KA, Su Y, Ge J. Cardiac resynchronization therapy via left bundle branch pacing vs. optimized biventricular pacing with adaptive algorithm in heart failure with left bundle branch block: a prospective, multi-centre, observational study. Europace. 2022 May 3;24(5):807-816. doi: 10.1093/europace/euab249.
- Burger H, Pecha S, Hakmi S, Opalka B, Schoenburg M, Ziegelhoeffer T. Five-year follow-up of transvenous and epicardial left ventricular leads: experience with more than 1000 leads. Interact Cardiovasc Thorac Surg. 2020 Jan 1;30(1):74-80. doi: 10.1093/icvts/ivz239.
- Kim HR, Lim K, Park SJ, Park JS, Kim JY, Chung S, Jung DS, Park KM, On YK, Kim JS. Thoracoscopic Implantation of Epicardial Left Ventricular Lead for Cardiac Resynchronization Therapy. J Cardiovasc Dev Dis. 2022 May 16;9(5):160. doi: 10.3390/jcdd9050160.
- Pujol-Lopez M, Jimenez-Arjona R, Garre P, Guasch E, Borras R, Doltra A, Ferro E, Garcia-Ribas C, Niebla M, Carro E, Puente JL, Vazquez-Calvo S, Invers-Rubio E, Roca-Luque I, Castel MA, Arbelo E, Sitges M, Brugada J, Tolosana JM, Mont L. Conduction System Pacing vs Biventricular Pacing in Heart Failure and Wide QRS Patients: LEVEL-AT Trial. JACC Clin Electrophysiol. 2022 Nov;8(11):1431-1445. doi: 10.1016/j.jacep.2022.08.001. Epub 2022 Oct 26.
- Vijayaraman P, Herweg B, Verma A, Sharma PS, Batul SA, Ponnusamy SS, Schaller RD, Cano O, Molina-Lerma M, Curila K, Huybrechts W, Wilson DR, Rademakers LM, Sreekumar P, Upadhyay G, Vernooy K, Subzposh FA, Huang W, Jastrzebski M, Ellenbogen KA. Rescue left bundle branch area pacing in coronary venous lead failure or nonresponse to biventricular pacing: Results from International LBBAP Collaborative Study Group. Heart Rhythm. 2022 Aug;19(8):1272-1280. doi: 10.1016/j.hrthm.2022.04.024. Epub 2022 Apr 30.
- Mair H, Sachweh J, Meuris B, Nollert G, Schmoeckel M, Schuetz A, Reichart B, Daebritz S. Surgical epicardial left ventricular lead versus coronary sinus lead placement in biventricular pacing. Eur J Cardiothorac Surg. 2005 Feb;27(2):235-42. doi: 10.1016/j.ejcts.2004.09.029.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- KCHRRF_CS Lead Failure_0025
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.