ElectrocardioGraphic Imaging During Left bUndle Branch Implant to valiDate Ecg Criteria (GUIDE)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Mariona Regany, MSc
- Phone Number: 93 2271778
- Email: regany@recerca.clinic.cat
Study Contact Backup
- Name: Jose M Tolosana, MD, PhD
- Phone Number: 93 2271778
- Email: tolosana@clinic.cat
Study Locations
-
-
-
Barcelona, Spain
- Hospital Clinic de Barcelona
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Left bundle branch pacing indication
- Capability of standing up to place the ECGI vest
Exclusion Criteria:
- Less than 18 years-old
- Patients with cognitive impairment
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Left Bundle Branch electrode implant
|
ECGI system to create non-invasive ventricular maps during the screwing steps of the LBBP electrode
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Left ventricular resynchronization assessed by ECGI
Time Frame: During procedure
|
Resynchronization assesed by non-invasive ECGI by the Left Ventricle Activation Time reduction and the septal activation ventricular pattern once reaching the LBBP according to the published ECG criteria.
|
During procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
VEU
Time Frame: During procedure
|
Ventricular Electrical Uncoupling computed as the difference between the mean activation time of the left and the right ventricle
|
During procedure
|
|
LVDI
Time Frame: During procedure
|
Left Ventricle Dyssinchrony Index computed as the standard deviation of individual activations recorded from the left ventricle.
|
During procedure
|
|
Histogram Overlap
Time Frame: During procedure
|
Overlapping of the right ventricle and left ventricle activation times histogram distributions as a parameter to assess the dyssinchrony between ventricles.
|
During procedure
|
|
LVAT
Time Frame: During procedure
|
Left Ventricular Activation Time computed as the difference between the earliest and the latest actvation of the left ventricle
|
During procedure
|
|
Isochronal Crowding
Time Frame: During procedure
|
Number of Isochrones presented in the left ventricular activation map to assess the homogeneity of the activation
|
During procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Jose Maria Tolosana, MD, PhD, Hospital Clinic of Barcelona
- Study Director: Margarida Pujol, MD, PhD, Hospital Clinic of Barcelona
- Principal Investigator: Lluis Mont Girbau, MD,PhD, Hospital Clinic of Barcelona
Publications and helpful links
General Publications
- Ploux S, Lumens J, Whinnett Z, Montaudon M, Strom M, Ramanathan C, Derval N, Zemmoura A, Denis A, De Guillebon M, Shah A, Hocini M, Jais P, Ritter P, Haissaguerre M, Wilkoff BL, Bordachar P. Noninvasive electrocardiographic mapping to improve patient selection for cardiac resynchronization therapy: beyond QRS duration and left bundle branch block morphology. J Am Coll Cardiol. 2013 Jun 18;61(24):2435-2443. doi: 10.1016/j.jacc.2013.01.093. Epub 2013 Apr 16.
- Huang W, Chen X, Su L, Wu S, Xia X, Vijayaraman P. A beginner's guide to permanent left bundle branch pacing. Heart Rhythm. 2019 Dec;16(12):1791-1796. doi: 10.1016/j.hrthm.2019.06.016. Epub 2019 Jun 22. No abstract available.
- Zhang S, Zhou X, Gold MR. Left Bundle Branch Pacing: JACC Review Topic of the Week. J Am Coll Cardiol. 2019 Dec 17;74(24):3039-3049. doi: 10.1016/j.jacc.2019.10.039. Epub 2019 Dec 9.
- Zhang W, Huang J, Qi Y, Wang F, Guo L, Shi X, Wu W, Zhou X, Li R. Cardiac resynchronization therapy by left bundle branch area pacing in patients with heart failure and left bundle branch block. Heart Rhythm. 2019 Dec;16(12):1783-1790. doi: 10.1016/j.hrthm.2019.09.006. Epub 2019 Sep 9.
- Wu S, Chen X, Wang S, Xu L, Xiao F, Huang Z, Zheng R, Jiang L, Vijayaraman P, Sharma PS, Su L, Huang W. Evaluation of the Criteria to Distinguish Left Bundle Branch Pacing From Left Ventricular Septal Pacing. JACC Clin Electrophysiol. 2021 Sep;7(9):1166-1177. doi: 10.1016/j.jacep.2021.02.018. Epub 2021 Apr 28.
- Elliott MK, Blauer J, Mehta VS, Sidhu BS, Gould J, Jackson T, Sieniewicz B, Niederer S, Ghosh S, Rinaldi CA. Comparison of electrical dyssynchrony parameters between electrocardiographic imaging and a simulated ECG belt. J Electrocardiol. 2021 Sep-Oct;68:117-123. doi: 10.1016/j.jelectrocard.2021.08.003. Epub 2021 Aug 8.
- Cai B, Huang X, Li L, Guo J, Chen S, Meng F, Wang H, Lin B, Su M. Evaluation of cardiac synchrony in left bundle branch pacing: Insights from echocardiographic research. J Cardiovasc Electrophysiol. 2020 Feb;31(2):560-569. doi: 10.1111/jce.14342. Epub 2020 Jan 20.
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Other Study ID Numbers
Other Study ID Numbers
- GUIDE
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.