Conventional vs Digital CAD/CAM Splints for Bruxism
Randomized Cross-clinical Trial Comparing Precision of Conventional Stabilization Splints (Michigan Type) Versus CAD/CAM Splints With Fully Digital Flow
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Rafael A Vidal, MS
- Phone Number: +5551999461583
- Email: rafaelaraujovidal@hotmail.com
Study Locations
-
-
RS
-
Porto Alegre, RS, Brazil, 90619-900
- Faculdade de Odontologia. Pontifícia Universidade Católica do Rio Grande do Sul.
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Adult patients aged between 20 and 55 years.
- Probable or confirmed diagnosis of sleep bruxism.
- No previous treatment with occlusal splints.
- Absence of periodontal diseases and/or dental fractures.
- Patients must have a minimum of 28 teeth.
Exclusion Criteria:
- Patients with systemic diseases affecting the temporomandibular joint, such as rheumatoid arthritis, osteoarthritis, and osteoporosis.
- Chronic users of medications that may interfere with the study results, including analgesics, anti-inflammatory drugs, anxiolytics, antidepressants, and anticonvulsants.
- Patients with a history of temporomandibular joint surgery.
- Pregnant or breastfeeding women.
- Patients with severe dental misalignment or malocclusion that would affect splint fitting and evaluation.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Crossover Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Digital occlusal splints (CAD/CAM)
Patients in this arm will receive a CAD/CAM occlusal stabilization splint created using a fully digital workflow. The process includes:
|
Consists of occlusal stabilization intra-oral splints fabricated using a fully digital workflow, involving intraoral scanning, virtual design, and 3D printing to ensure precise fit and comfort.
Other Names:
|
|
Active Comparator: Conventional occlusal splints
Patients in this arm will receive a conventional occlusal stabilization splint fabricated using traditional analog methods. The process includes:
|
Consists of occlusal stabilization splints fabricated using traditional analog methods, including physical impressions, plaster models, and manual processing with heat-cured acrylic resin to achieve the desired occlusal arrangement.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of occlusal contacts
Time Frame: Immediately after the initial installation
|
The number of occlusal contacts will be measured using the OccluSense® device
|
Immediately after the initial installation
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Time Required for Splint Adjustment
Time Frame: Immediately after the initial installation and adjustment
|
The time required to adjust each splint during the fitting process
|
Immediately after the initial installation and adjustment
|
|
Participant satisfaction after installation
Time Frame: Immediately after the initial installation and adjustment
|
Patients will assess their overall satisfaction with the splints using a 5-point Likert scale, with 1 meaning the lowest score of satisfaction and 5 meaning the highest score of satisfaction.
|
Immediately after the initial installation and adjustment
|
|
Participant satisfaction after 30 days
Time Frame: After 30 days of use
|
Patients will assess their overall satisfaction with the splints using a 5-point Likert scale, with 1 meaning the lowest score of satisfaction and 5 meaning the highest score of satisfaction.
|
After 30 days of use
|
|
Splint comfort after installation
Time Frame: Immediately after the initial installation and adjustment
|
Patients will assess comfort with the splints using a 5-point Likert scale, with 1 indicating the lowest level of comfort and 5 indicating the highest level of comfort.
|
Immediately after the initial installation and adjustment
|
|
Splint comfort after 30 days
Time Frame: After 30 days of use
|
Patients will assess comfort with the splints using a 5-point Likert scale, with 1 indicating the lowest level of comfort and 5 indicating the highest level of comfort.
|
After 30 days of use
|
|
Splint stability after installation
Time Frame: Immediately after the initial installation and adjustment
|
Patients will assess the stability of the splints (retention) during use using a 5-point Likert scale, with 1 indicating the lowest level of stability (frequent movement) and 5 indicating the highest level of stability (no movement).
|
Immediately after the initial installation and adjustment
|
|
Splint stability after 30 days
Time Frame: After 30 days of use
|
Patients will assess the stability of the splints (retention) during use using a 5-point Likert scale, with 1 indicating the lowest level of stability (frequent movement) and 5 indicating the highest level of stability (no movement).
|
After 30 days of use
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Chair: Marcio L Grossi, PhD, Pontificia Universidade Católica do Rio Grande do Sul
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 59319422.3.0000.5336
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.