Comparison of Bond Failure with Resin-modified Glass Ionomer Cement and Visible Light-cure Composite Bonding Material in Adult Orthodontic Patients - a Split-Mouth, Randomized Controlled Trial (RMGIC)
In this split mouth study design, 34 orthodontic patients coming for fixed appliance treatment will be bonded with standard light-cure composite bonding material and intervention of Resin Modified Glass Ionomer Cement (RMGIC). Contralateral quadrants will be allocated randomly for either RMGIC or visible light-cure composite bonding in both upper and lower jaw.
Quadrant 1: Randomly selected, contralateral upper and lower quadrants from central incisor to second premolar will be bonded with RMGIC bonding system.
Quadrant 2: Randomly selected, contralateral quadrants from central incisor to second premolar will be bonded with visible light-cure composite bonding material.
Allocation of diagonally opposite quadrants by either bonding system will be assigned randomly. Quadrants to be bonded with Resin-modified glass ionomer cement and light-cure composite bonding material will be switched from patient to patient to ensure randomization. This study is single blinded. The study investigators will not be blinded while the patient will be kept blinded.
On the first visit, a specially designed consent form will be signed by the participant.
Patient interaction for the purpose of study will only be for 1 hour duration while bonding of brackets. After six months amount and location of bond breakages will be evaluated from orthodontic record files.
This study will help us evaluate bond strength of RMGIC as compared to light cure composite. RMGIC can also be considered as the choice of material for bonding in high risk caries patients.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
MATERIAL & METHODS:
Study Design: Experimental study (Randomized Control Trial) Settings: Dental clinics, The Aga Khan University Hospital, Karachi (AKUH) Duration of Study: Patients will be recruited in this study for one and half hour. Chart analysis of these patients will then be done after six months of recruitment.
Sample Size:
Sample size was calculated with OpenEpi (version 3.01) sample size calculator using findings of Hegarty and Macfarlane14 who reported a bond failure percentage of 30% with light-cure adhesive and risk ratio of 2.6 (1.7, 3.9) for RMGIC as compared to resin based light cured composite. Keeping the above risk ratio at level of significance (α) 5% and power of study (1-β) 80%, at least 34 subjects were required for our study. The sample size will be inflated by 10% to account for sample attrition; therefore, a total of 37 subjects will be included in the study.
Sampling Technique: Non-probability consecutive sampling
Sample Selection:
Inclusion Criteria:
- Patients aged between 18-35 years
- Patients with fair to good oral hygiene who have no significant sign of gingivitis
- Healthy patients with no co-morbids such as rheumatic fever, blood dyscrasias, congenital heart disease, or diabetes mellitus
- Patients with class I, II and III malocclusions
- All patients who will sign the consent form
Exclusion Criteria:
- Enamel surface defects
- Pregnant patients or lactating mothers
- Syndromic patients
- Subjects with previous history of orthodontic or functional appliance treatment
DATA COLLECTION PROCEDURE:
Data will be collected by well-organized proforma. (Annexure H) Ethical approval will be taken from the institutional Ethical Review Committee (ERC) before commencement of the study. All those patients who sign an informed consent form (Annexure I) will receive detailed information regarding the study.
Due to ethical considerations, only patients requiring fixed appliance orthodontic treatment will be recruited. In this split mouth study design, contralateral quadrants will be allocated randomly for either Resin-modified glass ionomer cement or visible light-cure composite bonding in both upper and lower jaw. Randomization as per annerxure J Quadrant 1: Randomly selected, contralateral upper and lower quadrants from central incisor to second premolar will be bonded with RMGIC bonding system.
Quadrant 2: Randomly selected, contralateral quadrants from central incisor to second premolar will be bonded with visible light-cure composite.
On the first visit, a specially designed consent form will be signed by the participant. The investigator will unseal the envelope from Clinical Trials Unit (CTU), containing information regarding the participants based on randomization.
Ethical considerations:
Study will be carried out as per guidelines of World Medical Association's Declaration of Helsinki and principles of GCP (Good Clinical Practice). Any modifications in the protocol will be re-submitted to the ERC. The trial will be conducted in compliance with regulations and a copy of the final study protocol will be submitted to ERC.
Consent:
After assessment of eligibility criteria, participants will be included in this study after signing consent form. Consent form will be explained to patient in a separate dental room by investigators to ensure privacy. If patient will be unable to decide then consent form will be given to patient and asked to reply after decision in 7 days. One copy of consent will be given to patient after signing and one copy will be kept with the investigators.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Karachi, Pakistan
- Aga Khan University Hospital
-
-
Sindh
-
Karachi, Sindh, Pakistan, 75500
- Aga Khan University Hospital
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patients aged between 12-35 years
- Patients with fair to good oral hygiene who have no significant sign of gingivitis
- Healthy patients with no co-morbids such as rheumatic fever, blood dyscrasias, congenital heart disease, or diabetes mellitus
- Patients with class I, II and III malocclusions
Exclusion Criteria:
- Enamel surface defects
- Pregnant patients or lactating mothers
- Syndromic patients
- Subjects with previous history of orthodontic
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Control group ( light cure composite )
Product: Denturum Light Cure Band Adhesive (Ortho Organizers). Composition: 4 mg composite adhesive paste and 6 ml Transbond primer. Storage: Stored at room temperature and protected from humidity. Usage: Steps for light -cure composite bonding are:
|
The product will be stored by investigators at room temperature in lock and key. Product: Riva light cure RMGIC (HV) Composition: 18 mg orthodontic bonding paste and 6 ml enamel bond resin. Storage: Stored at room temperature and protected from humidity. Usage: Steps for Resin-modified glass ionomer cement composite bonding:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Bracket bond failure
Time Frame: Three months
|
The objective of this study is to compare rate of bond failures with Resin-modified glass ionomer cement and visible light-cure bonding.
|
Three months
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2022-5282-23281
- Dr. Aleem Saeed Qureshi (Other Identifier: AKUH)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Orthodontics
-
NCT02796911Completed
-
NCT03103802Unknown
-
NCT00871026Unknown
-
NCT06380790Recruiting
-
NCT05132764Recruiting
-
NCT03450278Completed
-
NCT06187337RecruitingCrowding of Anterior Maxillary Teeth | Orthodontics, Interceptive | Orthodontics, Corrective, Palatal Expansion Technique
-
NCT03924726Completed
Clinical Trials on Resin modified glass ionomer
-
NCT03304184TerminatedQuality of Life | Cervical Abrasion
-
NCT04671134Completed
-
NCT06135272Not yet recruiting
-
NCT03711097Withdrawn
-
NCT06711237Completed
-
NCT05605457Not yet recruiting
-
NCT05389163Completed
-
NCT04195386Unknown
-
NCT07443878CompletedMolar Hypomineralization, Incisor