Comparison of Oxygen Saturation Measurements Using Different Glove Colors in Children
Comparison of Oxygen Saturation Measurements Using Different Glove Colors in Children: A Preventive Method for Infection?
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Eliz Geçtan
- Phone Number: 05451342435
- Email: elizgectan09@gmail.com
Study Locations
-
-
-
Izmir, Turkey
- İzmirKCU
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Children between the ages of 3-18,
- The parent/legal guardian or the child himself/herself agrees to participate in the study,
- Arterial blood gas measurement was performed,
Exclusion Criteria:
- The finger has a skin condition,
- Having nail polish on your fingernails,
- Having a severed finger,
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
Experimental
Children will be measured 5 times using a pulse oximeter.
The measurements will be performed consecutively without any interval between them.
The first measurement will be performed without using any gloves on the patient's finger, the second measurement will be performed using transparent gloves, the third measurement will be performed using white gloves, the fourth measurement will be performed using black gloves, and the fifth measurement will be performed using blue gloves.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Measuring the arterial blood gas SpO2 saturation
Time Frame: Procedure
|
Finger SpO2 measurements will be initiated as soon as the blood gas measurement process starts.
Pulse oximetry measurements and intra-arterial blood gas measurements will be performed
|
Procedure
|
|
without gloves measuring the SpO2 saturation
Time Frame: While the patient was not wearing gloves, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
While the patient was not wearing gloves, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
|
|
SpO2 saturation measurement with transparent colored glove
Time Frame: While the patient was wearing a transparent glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
While the patient was wearing a transparent glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
|
|
SpO2 saturation measurement with white colored glove
Time Frame: While the patient was wearing a white glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
While the patient was wearing a white glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
|
|
SpO2 saturation measurement with black colored glove
Time Frame: While the patient was wearing a black glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
While the patient was wearing a black glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
|
|
SpO2 saturation measurement with blue colored glove
Time Frame: While the patient was wearing a blue glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
While the patient was wearing a blue glove, the pulse oximeter light source was placed on the outer surface of the finger. SpO2 was read after waiting an average of 30 seconds.
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 1753
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.