Evaluating Modulation Effects of Burst Stimulation Patterns Using SEEG
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Liankun Ren, MD
- Phone Number: +86 13681576621
- Email: renlk2022@outlook.com
Study Locations
-
-
Beijing
-
Beijing, Beijing, China, 100053
- Recruiting
- Xuanwu Hospital,Capital Medical University
-
Contact:
- Liankun Ren, MD
- Phone Number: +86 13681576621
- Email: renlk2022@outlook.com
-
Principal Investigator:
- Liankun Ren, MD
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Child
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Drug-resistant focal epilepsy
- Justified SEEG exploration in the context of presurgical assessment of epilepsy
- Subjects will be a part of the epilepsy-monitoring unit for long-term SEEG recordings and analysis
- Written non-opposition to study participation
Exclusion Criteria:
- Pregnant women (Contraindication to SEEG exploration)
- Psychiatric disorders
- History of psychotic disorders
- History of cranial trauma serious (according to the classification), previous or evolutionary other neurological pathology
- Subjects that experience surgical complications during the implant procedure will be excluded from the study
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Other
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Single-pulse stimulation
Single pulse electrical stimulation (SPES) is an investigational direct electrical stimulation (DES) pattern.
Direct cortical stimulation applied at a frequency of ∼1Hz can probe cortico-cortical connections by averaging electrocorticogram time-lock to the stimuli.
|
Investigators use single-pulse electrical stimulations at 1Hz to elicit cortico-cortical evoked potentials
|
|
Experimental: Paired-pulse stimulation
Paired-pulse stimulation paradigm associates a conditioning and a test stimulation to induce intracortical inhibition or facilitation by modifying the response amplitude.
|
The repetitive delivery of pairs of stimulation pulses is DES patten with a 5-50 ms interval between each pulse, constitutes repetitive paired-pulse stimulation.
|
|
Experimental: Stepwise frequency stimulation
Stepwise frequency stimulation is a DES protocol that incrementally increases the stimulation frequency, starting from a lower to higher.
|
Stepwise incremental stimulation ranging from 5 Hz to 145 Hz following a cyclic pattern.
|
|
Experimental: Burst stimulation
Burst stimulation is a DES patterned repetitive stimulation method; it represents a "more precise" and "smarter" electrical stimulation paradigm.
Within a group, high-frequency pulses are emitted, and between groups, low-frequency pulses are delivered.
This pattern of pulse delivery more closely mimics the physiological activity of neurons within the brain.
|
Burst stimulation pattern consisting of short bursts delivered once a second and an intraburst frequency of 50 Hz, 100 Hz, 150 Hz, 175 Hz and 200 Hz
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Modulation Factor
Time Frame: During the trial(up to 3 hours for each subject)
|
Investigators calculate normalized the Modulation Factors of single-pulse electrical stimulation, paired electrical stimulation, stepwise electrical stimulation, and burst electrical stimulation patterns using (stimulation-pre-stimulation)/(stimulation + pre-stimulation)
|
During the trial(up to 3 hours for each subject)
|
|
EEG power in spectral frequency bands
Time Frame: During the trial(up to 3 hours for each subject)
|
Using SEEG-implanted electrodes, the investigators applied electrical stimulation single-pulse electrical stimulation, paired electrical stimulation, stepwise electrical stimulation, and burst electrical stimulation while observing and recording EEG power changes across six spectral frequency bands during the pre-stimulation, stimulation, and post-stimulation periods. EEG Frequency Bands delta (1-4 Hz) theta (5-8 Hz) alpha (9-12 Hz) beta (13-30 Hz) low gamma (31-70 Hz) high gamma (71-150 Hz) |
During the trial(up to 3 hours for each subject)
|
|
Phase Locking Value
Time Frame: During the trial(up to 3 hours for each subject)
|
To estimate functional connectivity through the oscillatory synchrony of two brain regions, phase locking value (PLV) provides a measure of inter-regional synchrony based on phase difference between the paired signals.
|
During the trial(up to 3 hours for each subject)
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Liankun Ren, MD, Xuanwu Hospital, Beijing
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2024-173-002
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.