Induction and Stabilization of Gamma Oscillations With 40 Hz External Brain Stimulation
Gamma Oscillations and Working Memory Following Combined 40Hz tACS and iTBS
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
North Rhine-Westphalia
-
Dortmund, North Rhine-Westphalia, Germany, 44139
- Leibniz-Institut für Arbeitsforschung
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- normal or corrected to normal eye vision
- right-handed
- non-smokers
- being 18-60 years old
- providing written informed consent
Exclusion Criteria:
- history of neurological or psychiatric disorders including seizures or epilepsy,
- Taking CNS medication
- having metal implants
- current pregnancy
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Basic Science
- Allocation: Randomized
- Interventional Model: Single Group Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Transcranial alternating current stimulation
During tACS, an alternating electrical current with a 1 milliamp peak-to-peak amplitude will be delivered, featuring a 15-second ramp-up at the start and a 15-second ramp-down at the end.
The stimulation duration is 20 minutes and four channels are used for delivering sinusoidal alternating currents to the head.
The alternating current was delivered to the prefrontal cortex bilaterally with the electrodes at F3 and F4 and the return electrodes were placed at the ipsilateral mastoids at TP9 and TP10 (international 10-20 EEG electrode placement system).
|
Transcranial alternating current was delivered utilizing a Starstim 8-channel constant current, battery-powered electric stimulator (Neuroelectrics, Barcelona, Spain).
Circular carbon rubber electrodes (2cm radius, 12,57 cm2) were used throughout the stimulation.
Before placing the electrodes on the head, the subject's hair was moved to the side
|
|
Active Comparator: intermittent theta burst stimulation
The intermittent theta burst stimulation (iTBS) is regarded as safe for high-frequency neuromodulation.
The pulse bursts are applied for two seconds in 5Hz intervals followed by an eight-second break before the next bursts are applied.
This pattern is repeated for 190 seconds resulting in 600 pulses per protocol.
80% of the individual subjects' active motor threshold (AMT) are used for stimulation intensity and will be applied four times within a 20-minute time frame starting at 0 minutes, 5 minutes, 10 minutes, and 15 minutes from the beginning of the intervention resulting in 2400 delivered pulses for the whole intervention
|
the intermittent theta burst stimulation (iTBS) which is regarded as safe for high-frequency neuromodulation.
Compared to classical rTMS, where pulses are applied repeatedly at a fixed frequency, iTBS consists of bursts of pulse triplets.
In the classical protocol, the bursts are applied for two seconds in 5Hz intervals followed by an eight-second break, before the next bursts are applied.
This pattern is repeated for 190 seconds resulting in 600 pulses per protocol.
|
|
Active Comparator: combited iTBS- tACS peak
To combine tACS and the iTBS protocol, a customized circuit is developed in-house to phase-lock the TMS pulses to the waveform generated by tACS.
TMS pulses were delivered using two figure-of-eight shaped coils (double 70 mm, PMD coil type; Mag and More GmbH, Munich, Germany).
For the stimulation, the center of the TMS coils are placed over the two prefrontal tACS electrodes (F3 and F4 electrode positions) with an orientation of 45 degrees to the midline and the handles pointing backward.
Using the customized circuit, TMS pulses will be delivered at the peak of the tACS wave.
|
Transcranial alternating current was delivered utilizing a Starstim 8-channel constant current, battery-powered electric stimulator (Neuroelectrics, Barcelona, Spain).
Circular carbon rubber electrodes (2cm radius, 12,57 cm2) were used throughout the stimulation.
Before placing the electrodes on the head, the subject's hair was moved to the side
the intermittent theta burst stimulation (iTBS) which is regarded as safe for high-frequency neuromodulation.
Compared to classical rTMS, where pulses are applied repeatedly at a fixed frequency, iTBS consists of bursts of pulse triplets.
In the classical protocol, the bursts are applied for two seconds in 5Hz intervals followed by an eight-second break, before the next bursts are applied.
This pattern is repeated for 190 seconds resulting in 600 pulses per protocol.
|
|
Active Comparator: Combined iTBS-tACS trough
To combine tACS and the iTBS protocol, a customized circuit is developed in-house to phase-lock the TMS pulses to the waveform generated by tACS.
TMS pulses were delivered using two figure-of-eight shaped coils (double 70 mm, PMD coil type; Mag and More GmbH, Munich, Germany).
For the stimulation, the center of the TMS coils are placed over the two prefrontal tACS electrodes (F3 and F4 electrode positions) with an orientation of 45 degrees to the midline and the handles pointing backward.
Using the customized circuit, TMS pulses will be delivered at the trough of the tACS wave.
|
Transcranial alternating current was delivered utilizing a Starstim 8-channel constant current, battery-powered electric stimulator (Neuroelectrics, Barcelona, Spain).
Circular carbon rubber electrodes (2cm radius, 12,57 cm2) were used throughout the stimulation.
Before placing the electrodes on the head, the subject's hair was moved to the side
the intermittent theta burst stimulation (iTBS) which is regarded as safe for high-frequency neuromodulation.
Compared to classical rTMS, where pulses are applied repeatedly at a fixed frequency, iTBS consists of bursts of pulse triplets.
In the classical protocol, the bursts are applied for two seconds in 5Hz intervals followed by an eight-second break, before the next bursts are applied.
This pattern is repeated for 190 seconds resulting in 600 pulses per protocol.
|
|
Sham Comparator: sham
80% of the individual subjects' active motor threshold (AMT) four times within a 20-minute time frame starting at 0 minutes, 5 minutes, 10 minutes, and 15 minutes from the beginning of the intervention resulting in 2400 delivered pulses for the whole intervention
|
In the case of sham TMS, two different sham coils (double 70mm pCool-SHAM coil, Mag&More GmbH, Munich, Germany) will produce audible clicks at the decibel intensity corresponding to an active coil without the induction of an electromagnetic pulse.
Sham tACS will be applied by only ramping the current for 15 seconds up and 15 seconds down at the beginning and end of the stimulation respectively.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Working Memory behavioral performance
Time Frame: During procedure (20 minutes)
|
Participants view a continuous sequence of alphabet letters, presented as stimuli in Arial font, size 120pt, on a tube screen positioned at 60cm eye distance.
The stimuli are shown with a time interval of two seconds between them.
The task consisted of six blocks with 70 stimuli, including 12 possible hit trials.
Participants were instructed to press the left key on a response box if the presented stimulus matched either the one presented one trial prior (1-Back) or three trials prior (3-Back).
In all other cases, participants press the right key.
The left button is pressed with the index finger, while the right button is pressed with the middle finger of the right hand, with buttons aligned horizontally.
The response condition varied by block, with three blocks for 3-Back and three for 1-Back, and the order was counterbalanced across participants and sessions.
|
During procedure (20 minutes)
|
|
electroencephalogram (EEG) oscillatory power
Time Frame: up to 2 hours after the intervention
|
Change in the EEG power in alpha, delta, theta and beta bands
|
up to 2 hours after the intervention
|
|
electroencephalogram (EEG) functional connectivity
Time Frame: up to 2 hours after the intervention
|
Change in EEG functional connectivity, specifically global efficiency, coherence, and phase-locking value.
|
up to 2 hours after the intervention
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Publications and helpful links
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
- Brain Diseases
- Central Nervous System Diseases
- Nervous System Diseases
- Mental Disorders
- Neurocognitive Disorders
- Dementia
- Tauopathies
- Neurodegenerative Diseases
- Alzheimer Disease
- Therapeutics
- Behavioral Disciplines and Activities
- Electric Stimulation Therapy
- Convulsive Therapy
- Psychiatric Somatic Therapies
- Electroshock
- Psychological Techniques
- Transcranial Direct Current Stimulation
Other Study ID Numbers
Other Study ID Numbers
- IfADo_196
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.