Accuracy of Ultrasonography in Confirming Correct Positioning of Nasogastric Tube in the Intensive Care Setting
The goal of the study was to test whether a sonographic examination instead of an X-ray allows the position of a tube in the stomach to be checked.
Participants were patients admitted at an intensive care unit who required a nasogastric tube for several reasons (for example nutrition). After obtaining an informed consent from the patient or the family, the researchers checked the position of the tube with ultrasound and compared it with the gold standard, which is radiography. Data analysis allowed the concordance between the two tests to be analyzed.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Bellinzona, Switzerland
- Medicina Intensiva, Ente ospedaliero cantonale
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- age ≥ 18 years
- an already inserted nasogastric tube or required nasogastric tube insertion
- no contraindication for chest or abdominal X-ray
- no contraindication for neck and upper abdominal ultrasonography
Exclusion Criteria:
- pregnancy
- basal skull fractures
- facial fractures
- previous or recent surgery of the neck, esophagus or stomach
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Study population
|
The sonographic examination consisted of three parts: neck scan, epigastric scan, and injection test using a mixture of 25 mL NaCl 0.9% and 25 mL room air through the nasogastric tube to detect dynamic fogging
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Diagnostic accuracy of ultrasonography in determining correct nasogastric tube placement in the stomach
Time Frame: Through study completion (enrollment of approximately 180 patients)
|
In order to assess its diagnostic accuracy (sensitivity, specificity, negative predictive value, positive predictive value) we compared the index test (ultrasonography) against the reference standard (X-ray)
|
Through study completion (enrollment of approximately 180 patients)
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Estimated)
First Posted
Study Record Updates
Last Update Posted (Estimated)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- 2018-00036
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.