Validity and Reliability of the PhysioMaster Application in Measuring Wrist Range of Motion (ROM) Among Healthy Adults (PhysioMaster)
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Measuring Wrist ROM Using the electronic Goniometer
The following protocol will be implemented to measure wrist ROM for the enrolled female participants:
Wrist Flexion-Extension Testing Position: Elbow flexed at 90 degrees, with the wrist positioned over the edge of a table and the forearm in full pronation.
Goniometer Axis: Lateral placement over the triquetrum. Stationary Arm: Aligned with the lateral midline of the ulna, directed toward the olecranon process.
Moving Arm: Aligned with the lateral midline of the 5th metacarpal. Wrist Radial-Ulnar Deviation Testing Position: Elbow flexed at 90 degrees, wrist positioned over the edge of a table with the forearm in full pronation.
Goniometer Axis: Positioned over the dorsal capitate. Stationary Arm: Aligned with the dorsal midline of the forearm. Moving Arm: Positioned parallel to the longitudinal axis of the third metacarpal (Surangsrirat et al., 2022).
Measurement using the smartphone inclinometer-based application For measurements using the smartphone inclinometer application, the smartphone was placed on the participant's wrist, with elbows and upper arms positioned against a wall and flat along their torsos for each movement. This standardized setup ensured consistent smartphone positioning across all ROM measurements .
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- A sample of 30 female participants, aged 19 to 50 years, was selected for this study. Inclusion criteria required participants to be within this age range
Exclusion Criteria:
- any wrist pain, rheumatoid conditions, trauma, prior hand surgeries, deformities in either hand, or pregnancy
Study Plan
How is the study designed?
Design Details
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
wrist rane of motion
Time Frame: 4 weeks
|
This study employed the digital Goniometer to measure wrist Range of Motion (ROM) in terms of extension, flexion, radial deviation, and ulnar deviation.
Additionally, a smartphone inclinometer-based application, PhysioMaster, was used as a comparative tool, compatible with both Android and iOS systems
|
4 weeks
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- P.T.REC/012/005540
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.