Comparison of Single vs. Dual Perclose Devices for Large-Bore Access Closure in TAVR
Comparative Efficacy of Single vs. Dual Perclose Devices for Large-Bore Access Closure in Transcatheter Aortic Valve Replacement: A Randomized Controlled Trial
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Suhail Q Allaqaband, MD
- Phone Number: 414-649-3491
- Email: suhail.allaqaband@aah.org
Study Locations
-
-
Wisconsin
-
Milwaukee, Wisconsin, United States, 53215
- Recruiting
- Aurora St. Luke's Medical Center
-
Contact:
- Suhail Q Allaqaband, MD
- Phone Number: 414-649-3491
- Email: suhail.allaqaband@aah.org
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Patient age 18 or older
- Transfemoral transcatheter aortic valve replacement (TAVR)
- Implantation of CoreValve replacement valve
- Access using 14 French sheaths
- English speaking
Exclusion Criteria:
- Alternative Access Routes: Patients undergoing transcatheter aortic valve replacement (TAVR) via alternative access routes such as subclavian access or transapical access.
- Planned Surgical Cut-Down: Patients planned for surgical cut-down procedures rather than percutaneous access.
- Vascular Access Complications: Patients with known vascular complications at the femoral access site, such as residual hematoma, recent femoral arteriotomy or venotomy within the past 10 days, history of significant vascular complications or prior intravascular closure device use within the previous 30 days.
- Arterial or Venous Issues: Patients with small femoral arteries or veins (<5 mm in diameter), patients with access sites located in vascular grafts.
- Body Composition: Patients with BMI >35
- Cardiac Vasculature: Patients with excess calcification of vessels as determined by echocardiography and/or CT angiography
- Infection or Inflammation: Active systemic or cutaneous infection or inflammation in the vicinity of the groin.
- Coagulation and Hematological Disorders: Known history of bleeding diathesis, coagulopathy, hypercoagulability, or platelet count <100,000 cells/mm³. Pre-existing immunodeficiency disorder or chronic use of high-dose systemic steroids.
- Severe Morbidity: Severe co-existing morbidities with a life expectancy less than 12 months.
- Mobility Issues: Patients unable to routinely walk at least 20 feet without assistance.
- Recent Anticoagulation: Use of low molecular weight heparin (LMWH) within 8 hours before or after the procedure.
- Pregnancy and Lactation: Pregnant or lactating women.
- Incompatible Procedure Plan: Patients receiving the Edwards Sapien valve (Edwards Lifesciences, Irvine, CA)
- Contraindications: Patients with contraindications for the use of Perclose device.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Single Device
A single Perclose device will be used for pre-closure of the vascular access site, with manual pressure and up to two additional devices used as needed to achieve hemostasis.
|
Use of a single Perclose device for pre-closure of vascular access site after removal of TAVR sheath.
|
|
Active Comparator: Two device
Two Perclose devices will be used for pre-closure of the vascular access site, with manual pressure and an additional device used as needed to achieve hemostasis.
|
Use of two Perclose devices for pre-closure of vascular access site after removal of TAVR sheath.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Number of Patients With Vascular Complications
Time Frame: Day 5 post-procedure
|
Number of subjects in each group experiencing major or minor vascular complications directly related to the TAVR procedure occurring during the index hospitalization.
|
Day 5 post-procedure
|
|
Number of Patients With Life-threatening bleeding
Time Frame: Hour 24 post-procedure
|
Number of subjects in each group experiencing any bleeding event related to the TAVR procedure that is life-threatening within 24 hours post-procedure.
|
Hour 24 post-procedure
|
|
Number of Patients With Major or Minor Bleeding Complications Without Life-Threatening Condition
Time Frame: Hour 24 post-procedure
|
Number of subjects in each group experiencing bleeding complications related to the TAVR procedure that do not meet the criteria for life-threatening bleeding but still result in significant clinical concern within 24 hours of the index procedure.
|
Hour 24 post-procedure
|
|
Time to Hemostasis
Time Frame: 1 hour post procedure
|
For each subject, time elapsed from initial deployment of the initial one or two Perclose devices (depending on assigned group) to complete hemostasis of the femoral access site.
Measured in seconds.
|
1 hour post procedure
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Additional Closure Device Use
Time Frame: Hour 24 post-procedure
|
Number of subjects requiring use of additional closure devices beyond the initial closure strategy required to achieve hemostasis at the femoral access site within 24 hours post-procedure.
The number and type of devices will be recorded for each subject.
|
Hour 24 post-procedure
|
|
In-Hospital Serious Vascular Complications Requiring Percutaneous or Surgical Interventions
Time Frame: Day 5 post-procedure
|
Number of subjects in each group experiencing severe vascular complications that necessitate either percutaneous procedures or surgical interventions during the index hospitalization.
|
Day 5 post-procedure
|
|
Number of Patients With Limb Ischemia Related to TAVR During Index Admission
Time Frame: Day 5 post-procedure
|
Number of subjects in each group experiencing significant peripheral ischemia related to the arteriotomy closure between the TAVR procedure and discharge.
|
Day 5 post-procedure
|
|
Limb Ischemia Related to TAVR
Time Frame: Day 30 post-procedure
|
Number of subjects in each group experiencing significant peripheral ischemia related to the arteriotomy closure monitored within 30 days post procedure.
|
Day 30 post-procedure
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Suhail Q Allaqaband, MD, Wake Forest University Health Sciences
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- IRB00124842
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.