On Previously Root Canal-treated Patients Using an AI Program, Detect the Accuracy of it in the Detection of Root Canal Obturation Quality on CBCT Compared With Conventional PA Radiography, e.g., Voids, Length of Obturation, and Density, and Then do Retreatment if Any Failure is Recorded. (AI)
Accuracy of Artificial Intelligence Technology in Detecting the Quality of Endodontic Treatment Diagnostic Accuracy Experimental Study.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Cairo, Egypt, 11835
- Faculty of Oral and Dental Medicine future university
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Medically free patients with no systemic disease: (American Society of Anesthesiologists / (ASA Class I or II).
- Age range is between18 to 50 years
- No sex predilection.
- All patients must have good oral hygiene. 5 -patients with root canal-treated teeth.
6- restorable teeth. 7- Positive patient acceptance for participating in the study. 8- Patients can sign informed consent.
Exclusion Criteria:
- 1-Patients with very poor oral hygiene. 2-Patients above 50 years and below 18 years. 3-Pregnant and lactating women 4-Psychologically disturbed patients. 5-nonrestorable teeth.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Sequential Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Length of Root Filling
1. Length of Root Filling Ideal: 0-2 mm short of the radiographic apex Overfilling: Beyond the apex - may lead to periapical irritation Underfilling: More than 2 mm short - associated with poor prognosis Measuring unit: millimeters (mm) from the radiographic apex
|
if Retreatment was needed, local anesthesia using 1.8 ml (one cartridge) of 4% articaine with 1:100,000 epinephrine local anesthetic solution, administered with end -loading cartridge aspirating syringe and a 27-gauge long needle.
Under rubber dam isolation, All carious tissue and existing coronal restorations were thoroughly removed using a round bur, an endodontic access cavity, canal preparation and removal of existing root canal filling, irrigation with 2.6% NAOCL and saline, determining the working length using apex locator and PA radiograph, to be 0.5 to 1 mm shorter than radiographic apex, Drying the canal with paper point and obturation to achieve a dense, well adapted Monoblock obturation.
A post-obturation periapical radiograph was taken to confirm the quality of the fill in terms of length, density, then sealed by a temporary restorative material.
|
|
Active Comparator: Density/Homogeneity
Criteria: No visible voids in: Canal system, Between gutta-percha and canal wall Assessment: Radiographic inspection (digital or analog) Measuring tool: Qualitative (visual rating) or CBCT grayscale values for homogeneity
|
if Retreatment was needed, local anesthesia using 1.8 ml (one cartridge) of 4% articaine with 1:100,000 epinephrine local anesthetic solution, administered with end -loading cartridge aspirating syringe and a 27-gauge long needle.
Under rubber dam isolation, All carious tissue and existing coronal restorations were thoroughly removed using a round bur, an endodontic access cavity, canal preparation and removal of existing root canal filling, irrigation with 2.6% NAOCL and saline, determining the working length using apex locator and PA radiograph, to be 0.5 to 1 mm shorter than radiographic apex, Drying the canal with paper point and obturation to achieve a dense, well adapted Monoblock obturation.
A post-obturation periapical radiograph was taken to confirm the quality of the fill in terms of length, density, then sealed by a temporary restorative material.
|
|
Active Comparator: Presence of Voids
Criteria: Voids indicate poor condensation or adaptation Assessment tools: Periapical radiographs, CBCT.
Measuring unit: Number, size (mm or μm), or volume (%) of voids
|
if Retreatment was needed, local anesthesia using 1.8 ml (one cartridge) of 4% articaine with 1:100,000 epinephrine local anesthetic solution, administered with end -loading cartridge aspirating syringe and a 27-gauge long needle.
Under rubber dam isolation, All carious tissue and existing coronal restorations were thoroughly removed using a round bur, an endodontic access cavity, canal preparation and removal of existing root canal filling, irrigation with 2.6% NAOCL and saline, determining the working length using apex locator and PA radiograph, to be 0.5 to 1 mm shorter than radiographic apex, Drying the canal with paper point and obturation to achieve a dense, well adapted Monoblock obturation.
A post-obturation periapical radiograph was taken to confirm the quality of the fill in terms of length, density, then sealed by a temporary restorative material.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
root canal quality Length of Root Filling
Time Frame: preprocedural(day 1) and if treatment needed after the completion of the it up to 1month
|
Length of Root Filling Ideal: 0-2 mm short of the radiographic apex Overfilling: Beyond the apex - may lead to periapical irritation Underfilling: More than 2 mm short - associated with poor prognosis Measuring unit: millimeters (mm) from the radiographic apex
|
preprocedural(day 1) and if treatment needed after the completion of the it up to 1month
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Other Study ID Numbers
Other Study ID Numbers
- FUE.REC(44)/11-2024
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
IPD Sharing Time Frame
IPD Sharing Supporting Information Type
- STUDY_PROTOCOL
- ICF
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.