To Evaluate the Complete Mandibular Dentures Produced Via 3D Printing in Comparison to Those Constructed From Metal-reinforced Acrylic Resin Regarding Their Retention (retention)
Comparative Study of Retention of Mandibular Denture Bases Three-dimensional (3D) Printing Technique and Metal-reinforced Acrylic Resin
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Cairo, Egypt, 11553
- National Resaerch Center
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Class I maxillary-mandibular relationship
- well-maintained oral mucosa
- normal salivary flow
Exclusion Criteria:
- smokers patient
- patient had any abnormalities in hard or soft tissues
- severe ridge undercut
- patient received radiation therapy to the head and neck region
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: complete edentulous patient receive 3D printed denture
group 1: 10 patients: Complete dentures constructed from poly-methyl methacrylate resin were used to create the mandibular and maxillary 3D-printed dentures
|
different method of denture construction
|
|
Active Comparator: complete edentulous patient receive metal reinforced denture
group 2: 10 patients: complete denture constructed from metal reinforced acrylic denture
|
different method of denture construction
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
retention measurement
Time Frame: immediatlly after denture construction
|
To assess retention, a digital force gauge (Digital Force Gauge EXTECH 475044) was employed.
All of the mandibular dentures were modified to receive a custom-made metal framework consisting of three tubes connected by a hook at the determining geometric center of the denture, two tubes extend 2 cm above the occlusal plane from the retromolar pad region, and one was made at the midline region lingual and below the central incisors.
The mandibular denture's polished surface was then joined to the specially constructed custom-made metal framework using self-curing acrylic resin
|
immediatlly after denture construction
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Principal Investigator: Ayman F Elawady, Ass prof, National research center, cairo, Egypt
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 8887082022
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.