Repositioning the Bolus Tracking ROI to the Superior Vena Cava in CTPA Facilitates Contrast Volume Reduction
Optimising Bolus Tracking Technique by Repositioning the Region of Interest (ROI) at the Superior Vena Cava and Reducing Contrast Media Volume in Computed Tomography Pulmonary Angiography (CTPA)
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
Background and Rationale: Computed Tomography Pulmonary Angiography (CTPA) is the gold standard for diagnosing pulmonary embolism (PE). However, standard bolus tracking (BT) protocols that place the monitoring region-of-interest (ROI) on the main pulmonary trunk (PT) often face challenges due to the system's inherent Transit Delay Time (TDT). This delay, typically 5 seconds, can cause the diagnostic scan window to overlap with the venous phase, leading to suboptimal arterial opacification and venous contamination. This study proposes repositioning the monitoring ROI upstream to the superior vena cava (SVC) to utilize the TDT as transit time for the bolus, thereby aligning the scan window with the peak arterial phase.
Study Objectives: The primary objective is to evaluate the effect of SVC ROI repositioning on diagnostic image quality while investigating the feasibility of reducing contrast media (CM) volume by 40% (from 50 ml to 30 ml).
Methodology: This is a single-center, prospective, randomized controlled trial involving 72 adult patients. Participants are randomized into four protocol groups:
Group A (Control): ROI at PT, 50 ml contrast media. Group B: ROI at PT, 30 ml contrast media. Group C: ROI at SVC, 50 ml contrast media. Group D: ROI at SVC, 30 ml contrast media.
Protocol Details:
- Contrast Administration: Non-ionic contrast medium (370 mgI/ml) is injected at a rate of 4 ml/s, followed by a 20 ml saline flush.
- Bolus Tracking: An elliptical ROI is placed either on the PT (above the carina) or SVC depending on the group assignment.
- Triggering: The diagnostic scan is automatically initiated when enhancement reaches a threshold of 100 HU. The TDT is set to a fixed 5 seconds.
- Assessment: Diagnostic quality is assessed quantitatively by calculating arterial-venous enhancement differences (HU) and qualitatively via a 5-point Likert scale by three blinded radiologists.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
Sabah
-
Kota Kinabalu, Sabah, Malaysia, 88200
- Hospital Queen Elizabeth
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- All patients scheduled for a Computed Tomography Pulmonary Angiography (CTPA) examination.
- Provision of written informed consent by the subject, guardian, or medical specialist.
- Patients with an upper extremity intravenous (IV) line using a 16-20 gauge cannula.
- Patients with a stable heart rate between 60 and 120 beats per minute (bpm).
Exclusion Criteria:
- Pregnancy, breastfeeding, or use of non-reliable methods of contraception.
- Patients with impaired renal function, including acute kidney injury or chronic kidney disease (CKD) with an eGFR less than 30 mL/min/1.73m².
- Patients with a lower extremity IV line, as this bypasses the Superior Vena Cava (SVC) and results in bolus tracking technique failure.
- Patients with a heart rate lower than 60 bpm or higher than 120 bpm.
- Patients with a cannula size of 22g or smaller, as it cannot accommodate the high flow rate (4 mL/s) required by the power injector.
- Patients with severe cardiac impairment or congenital heart disease.
- Patients with a Body Mass Index (BMI) exceeding 35 kg/m², as severe obesity causes beam hardening effects that degrade image quality.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Active Comparator: Group A: PT-ROI, 50 ml (Control)
Standard CTPA protocol using the bolus tracking technique with the monitoring region of interest (ROI) placed at the pulmonary trunk (PT) and 50 ml of contrast media.
|
CTPA scans are performed on a 128-slice CT scanner using the bolus tracking technique.
Non-ionic contrast medium (370 mgI/ml) is administered at a rate of 4 ml/s, followed by a 20 ml saline flush.
The diagnostic scan is automatically triggered when enhancement in the monitoring region of interest (ROI) reaches a threshold of 100 HU, with a fixed transit delay time (TDT) of 5 seconds.
|
|
Experimental: Group B: PT-ROI, 30 ml
Modified CTPA protocol using the bolus tracking technique with the monitoring ROI at the pulmonary trunk (PT) and a reduced contrast volume of 30 ml.
|
CTPA scans are performed on a 128-slice CT scanner using the bolus tracking technique.
Non-ionic contrast medium (370 mgI/ml) is administered at a rate of 4 ml/s, followed by a 20 ml saline flush.
The diagnostic scan is automatically triggered when enhancement in the monitoring region of interest (ROI) reaches a threshold of 100 HU, with a fixed transit delay time (TDT) of 5 seconds.
|
|
Experimental: Group C: SVC-ROI, 50 ml
Modified CTPA protocol using the bolus tracking technique with the monitoring ROI repositioned upstream to the superior vena cava (SVC) and 50 ml of contrast media.
|
CTPA scans are performed on a 128-slice CT scanner using the bolus tracking technique.
Non-ionic contrast medium (370 mgI/ml) is administered at a rate of 4 ml/s, followed by a 20 ml saline flush.
The diagnostic scan is automatically triggered when enhancement in the monitoring region of interest (ROI) reaches a threshold of 100 HU, with a fixed transit delay time (TDT) of 5 seconds.
|
|
Experimental: Group D: SVC-ROI, 30 ml
Modified CTPA protocol using the bolus tracking technique with the monitoring ROI repositioned upstream to the superior vena cava (SVC) and a reduced contrast volume of 30 ml.
|
CTPA scans are performed on a 128-slice CT scanner using the bolus tracking technique.
Non-ionic contrast medium (370 mgI/ml) is administered at a rate of 4 ml/s, followed by a 20 ml saline flush.
The diagnostic scan is automatically triggered when enhancement in the monitoring region of interest (ROI) reaches a threshold of 100 HU, with a fixed transit delay time (TDT) of 5 seconds.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Mean Difference in Hounsfield Unit (HU) Attenuation Between Pulmonary Artery and Pulmonary Vein
Time Frame: At the time of post-procedural image analysis (approximately 48 hours after CTPA scan completion).
|
This quantitative measurement assesses the degree of arterial opacification relative to venous contamination by calculating the difference in Hounsfield Units (HU).
It is calculated by subtracting the mean HU value of the pulmonary vein from the mean HU value of the pulmonary artery at the same anatomical level.
A larger positive difference indicates superior arterial enhancement with minimal venous contamination.
|
At the time of post-procedural image analysis (approximately 48 hours after CTPA scan completion).
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Qualitative Image Quality Score using a 5-point Likert Scale
Time Frame: Within 1 month following the CTPA scan.
|
Qualitative assessment of CTPA images performed by three blinded senior radiologists using a 5-point Likert scale (1 = Unacceptable, 2 = Sub-optimal, 3 = Acceptable, 4 = Good, 5 = Excellent).
The score evaluates overall arterial enhancement, presence of artifacts, and diagnostic adequacy.
|
Within 1 month following the CTPA scan.
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Study Chair: Kamarul Amin. bin Abdullah @ Abu Bakar., Assoc. Prof. Ts. Dr., Universiti Sultan Zainal Abidin (UniSZA)
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- NMRR-20-699-54086 (IIR)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
IPD Plan Description
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.