EpiFaith Resident Learning Curve Trial
Impact of the EpiFaith® Syringe on the Learning Curve of Anesthesia Residents for the Labor Epidural Technique: A Quasi-Experimental Study
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
The lumbar epidural technique for labor analgesia requires technical training and a manual skillset. A prior study evaluating anesthesia resident learning curves for a traditional labor epidural technique demonstrated a steep learning curve for the first 20 epidural placements, followed by a plateau with gradual proficiency maximized after 60 epidural placements (1). A prior study evaluated a spring-loaded epidural syringe among experienced providers (2). However, the impact of a spring-loaded epidural syringe on novice anesthesia resident learning curves is unknown. In addition, the impact of EpiFaith® use at the time of manual skill acquisition on success with subsequent traditional epidural technical skills is unknown.
The EpiFaith® syringe is FDA-cleared and has a spring-loaded piston designed to detect entry into the epidural space upon loss of resistance (LOR) as the epidural needle tip moves from the dense ligamentum flavum to the high-compliance epidural space. Performing the LOR technique using the EpiFaith® syringe, the piston within the syringe moves forward driven by spring force when a drop in pressure is detected. Piston movement within the syringe is visibly detectable with a yellow indicator in the syringe when LOR occurs. In a feasibility study of 40 labor epidural placements, 3 of 4 expert obstetric anesthesiology physicians reported the EpiFaith® syringe to be equal to superior in quality to the standard LOR syringe, with 100% success rate and no inadvertent dural punctures (3).
Evaluating the impact of the EpiFaith® syringe on learning curves of anesthesia residents with minimal prior technical experience will help inform how we approach education regarding the labor epidural technique. Steeper learning curves with faster time to proficiency may benefit both patients and supervising staff, while if no difference is determined, the use of the EpiFaith® syringe can be de-emphasized during the training period.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Michaela K Farber, MD MS
- Phone Number: 617-759-1609
- Email: mfarber@bwh.harvard.edu
Study Contact Backup
- Name: Noor A Raheel, MD
- Phone Number: 617-732-8251
- Email: nraheel@bwh.harvard.edu
Study Locations
-
-
Massachusetts
-
Boston, Massachusetts, United States, 02115
- Recruiting
- Brigham and Women's Hospital
-
Contact:
- Michaela K Farber, MD MS
- Phone Number: 617-759-1609
- Email: mfarber@bwh.harvard.edu
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Anesthesiology residents with fewer than 5 prior epidural placement experiences
Exclusion Criteria:
- anesthesiology residents with more than 5 prior epidural placement experiences
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Supportive Care
- Allocation: Non-Randomized
- Interventional Model: Factorial Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Control (glass epidural syringe)
|
glass epidural syringe
|
|
Experimental: EpiFaith syringe
|
The EpiFaith syringe is an FDA-cleared epidural syringe.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
success of labor epidural attempt
Time Frame: time of epidural placement to 30 minutes after dosing of the epidural
|
success of labor epidural attempt over time by each resident, with success defined as a composite requiring:
|
time of epidural placement to 30 minutes after dosing of the epidural
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
rating of the epidural syringe
Time Frame: from time of placement to immediately following placement
|
rating of the epidural syringe loss of resistance technique
|
from time of placement to immediately following placement
|
|
Incidence of inadvertent dural puncture
Time Frame: from time of epidural placement for a maximum of 5 days
|
incidence of inadvertent dural puncture
|
from time of epidural placement for a maximum of 5 days
|
|
incidence of postdural puncture headache
Time Frame: from time of epidural placement up to 5 days
|
incidence of postdural puncture headache
|
from time of epidural placement up to 5 days
|
|
Need for epidural catheter replacement during labor
Time Frame: from time of epidural placement through delivery during hospital admission
|
need for epidural catheter replacement during labor
|
from time of epidural placement through delivery during hospital admission
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 2023P001926
- 2023A006350 (Other Grant/Funding Number: Flat Medical)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.