Loop Recorder Implantation in Patients With Mitral Annular Disjunction (ILR MAD IIT)
The goal of clinical trial is to prospectively collect data to investigate the prevalence of arrhythmia in young patients diagnosed with mitral annular disjunction who have no indication for implantable cardioverter defibrillator (ICD) or implantable loop recorder (ILR) implantation according to the current guideline. The study population is young (age 18-60), the participating patients have mitral annular disjunction confirmed by echocardiography and MR scan confirmed late-type gadolinium enhancement in the myocardium. This patient population has an increased risk of ventricular arrhythmias and sudden cardiac death. The investigators plan to implant 20 BioMonitor IIIm ILRs over a year in patients with mild or uncertain symptoms (dizziness, palpitations) and no malignant arrhythmias.
Aims of the study:
- Screening of asymptomatic patients with MAD for arrhythmia.
- In case of symptoms, to prove or exclude the underlying arrhythmia.
BioMonitor IIIm ILR implantation is planned in the following patient population:
- Inclusion of 20 patients with mitral annular disjunction confirmed by echocardiography and late gadolinium enhancement in the myocardium by MRI.
- Only patients who do not meet the current indication for ICD or ILR implantation based on the current recommendation will be included in the study.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Attila Kardos, MD PhD
- Phone Number: +36703388864
- Email: attila.kardos@gokvi.hu
Study Contact Backup
- Name: Sara Mladoniczky, MD
- Phone Number: +36301550424
- Email: sara.mladoniczky@gokvi.hu
Study Locations
-
-
-
Budapest, Hungary, 1096
- Recruiting
- Gottsegen National Cardiovascular Institute
-
Contact:
- Attila Kardos, MD PhD
- Phone Number: +36703388864
- Email: attila.kardos@gokvi.hu
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- age between 18 and 60 years
- patient not incapacitated
- mitral annular disjunction confirmed by echocardiography
- MR scan confirmed late-type gadolinium enhancement in the myocardium
Exclusion Criteria:
- lack of informed consent
- age under 18 years
- limited capability
- guardianship
- active infection
- cancer
- previous ICD implantation
- indication for ICD or ILR implantation based on current recommendation
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: N/A
- Interventional Model: Single Group Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: MAD-ILR
Patients with mitral annular disjunction, confirmed by echocardiography and MR scan confirmed late-type gadolinium enhancement in the myocardium, undergoing loop recorder implantation.
|
During the operation, a small incision is made in the chest with local anesthesia and the implantation is performed in a pacemaker operating room, following the rules of sepsis/antisepsis.
The surgical suture is used to close the wound.
The healing time is about 10 days, during which time a covering bandage is needed.
During the operation we use absorbable sutures, no suture removal is necessary.
After implantation, the patient's lifestyle is not restricted.
Avoidance of strong magnetic fields, which may result in noise recording, is necessary.
The procedure is performed as an outpatient surgery and patients are discharged to their homes on the day of the procedure.
Other Names:
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Ventricular arrhythmia screened with loop recorder
Time Frame: 24 months
|
Periprocedurally, at 6-, 12-, 18- and 24-month follow-up, we perform control examinations (e.g.
12-lead ECG, echocardiography, ILR interrogation).
Arrhythmias recorded by ILR are documented and analyzed.
Our results may contribute to a better understanding of the indications for ILR and ICD implantation in patients with MAD, thereby helping to reduce the risk of sudden cardiac death.
|
24 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Investigators
Investigators
- Principal Investigator: Attila Kardos, MD PhD, Gottsegen National Cardiovascular Institute
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- 1034
- FF110 (Other Grant/Funding Number: BIOTRONIK SE & Co. KG)
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
product manufactured in and exported from the U.S.
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Sudden Cardiac Death Due to Cardiac Arrhythmia
-
NCT06739239RecruitingDefibrillators, Implantable | Sudden Cardiac Death Due to Cardiac Arrhythmia
-
NCT06804499RecruitingSudden Cardiac Death | Sudden Cardiac Death Due to Cardiac Arrhythmia | Sudden Cardiac Arrest | Coronary Arterial Disease (CAD) | Acute Coronary Event
-
NCT06888271Not yet recruitingSudden Cardiac Death Due to Cardiac Arrhythmia | Brugada Syndrome
-
NCT04599439RecruitingMyocardial Infarction | Arrhythmias, Cardiac | Ventricular Tachycardia | Ventricular Arrythmia | Sudden Cardiac Death | Myocardial Infarction Old | Sudden Cardiac Death Due to Cardiac Arrhythmia
-
NCT04246450RecruitingDilated Cardiomyopathy | Sudden Cardiac Death Due to Cardiac Arrhythmia
-
NCT06321900RecruitingCardiovascular Diseases | Cardiomyopathies | Ischemic Heart Disease | Sudden Cardiac Death Due to Cardiac Arrhythmia
-
NCT04548804Enrolling by invitationVentricular Fibrillation | Heart Arrest | Ventricular Tachycardia | Cardiac Arrest | Congenital Heart Disease | Ventricular Arrythmia | Polymorphic Ventricular Tachycardia | Sudden Cardiac Death | Cardiac Arrhythmia | Cardiac Death
-
NCT04675073RecruitingMyocardial Infarction | Ischemic Heart Disease | Ventricular Tachycardia | Magnetic Resonance Imaging | Ventricular Arrythmia | Sudden Cardiac Death | Sudden Cardiac Death Due to Cardiac Arrhythmia
-
NCT07020702RecruitingCardiomyopathies | Ventricular Arrhythmia | Left Ventricular Ejection Fraction Less Then or Equal to 50percent
-
NCT07545512Not yet recruitingSudden Cardiac Death Due to Cardiac Arrhythmia | Myocardial Infarction (MI)
Clinical Trials on loop recorder implantation
-
NCT04554160RecruitingArrhythmias, Cardiac | Pulmonary Hypertension | Heart Rate Variability | Risk Assessment
-
NCT06055751RecruitingAortic Stenosis | Heart Block | Atrial Fibrillation New Onset
-
NCT01503268Withdrawn
-
NCT04542460Active, not recruitingChronic Total Coronary Occlusion
-
NCT06589700RecruitingStroke | Atrial Fibrillation
-
NCT05974306Not yet recruiting
-
NCT05169320Recruiting
-
NCT05896592Recruiting