Accuracy of Positioning Guide and Customized Plate in Zygomaticomaxillary Complex Fracture

November 1, 2026 updated by: Abdellatif Saad Abdellatif Nawar, Cairo University

Accuracy of Positioning Guide and Customized Titanium Plate for Reduction and Fixation of Zygomaticomaxillary Complex Fracture: A Case Series

This prospective, single-arm case series aims to evaluate the accuracy of a virtual planning-based positioning guide and customized titanium plate for the reduction and fixation of unilateral zygomaticomaxillary complex (ZMC) fractures.

The primary objective is to assess fracture reduction accuracy by comparing postoperative CT findings with the preoperative virtual surgical plan. Secondary objectives are to evaluate fixation stability and patient satisfaction.

Participants undergo preoperative CT imaging for virtual surgical planning, followed by surgical reduction and fixation using a patient-specific positioning guide and customized titanium plate. Postoperative CT imaging is used to assess reduction accuracy, with subsequent follow-up to evaluate fixation stability and patient satisfaction.

Study Overview

Status

Enrolling by invitation

Conditions

Intervention / Treatment

Detailed Description

The study evaluates the accuracy of a patient-specific positioning guide and customized titanium plate for the reduction and fixation of unilateral zygomaticomaxillary complex (ZMC) fractures.

All patients undergo a thorough medical and dental history and comprehensive clinical examination. Clinical measurements and photographic documentation are obtained to assess facial symmetry, ocular function, and mouth opening. A preoperative computed tomography (CT) scan (T0) is obtained within one week before surgery to assess the fracture pattern and the extent of displacement. The Digital Imaging and Communications in Medicine (DICOM) data are imported into specialized medical imaging software (e.g., Mimics, 3-matic, or equivalent) for three-dimensional reconstruction and virtual surgical planning (VSP).

During the virtual planning phase, the fractured zygomaticomaxillary complex is first virtually reduced by mirroring the unaffected contralateral side to establish the planned anatomical position. If mirroring is not feasible, established anatomical landmarks and anatomical norms are used to guide the virtual reduction. The customized titanium plate is then designed on the virtually reduced model to fit the planned bone contours. The screw positions and trajectories are also planned, and the screws are virtually positioned within their corresponding fracture segments to define the intended fixation configuration.

After finalizing the plate and screw design in the reduced position, the zygomatic complex is virtually returned to its original displaced fracture position while maintaining the planned screw positions relative to their respective bone segments. The patient-specific positioning guide is then designed on this unreduced model. The guide incorporates the planned drilling locations, allowing the screw holes to be predrilled in the original fracture position. These predrilled holes subsequently guide the reduction and allow the customized plate to be positioned and fixed according to the original virtual surgical plan.

The customized titanium plate is designed using computer-aided design (CAD) and manufactured using computer-aided manufacturing (CAM). The design is exported in STL format, and machining programs are generated for production. The plate is fabricated from medical-grade Titanium Grade 4 using a three-axis CNC milling machine (MILLSTAR, Taiwan), through a subtractive manufacturing process. The machined plate undergoes deburring, polishing, anodizing, cleaning, and packing before use. Digital planning and fabrication are performed by Arab Engineers for Designs and Medical Instrumentation in collaboration with the research team.

Surgical treatment is performed under general anesthesia using lateral eyebrow and intraoral vestibular incisions to expose the fracture site. The patient-specific positioning guide is placed on the zygomatic complex in its original displaced fracture position. The planned screw holes are predrilled through the guide. After removal of the guide, the fracture segments are reduced using the predrilled holes as references to reproduce the planned anatomical position. The customized titanium plate is then positioned according to the planned screw positions and secured with screws to achieve fixation. The surgical site is irrigated and the incisions are closed in layers.

A postoperative CT scan (T1) is obtained within one week after surgery to assess the accuracy of fracture reduction and plate placement. The preoperative virtual surgical plan and postoperative CT model are imported into imaging software and superimposed. Linear and angular deviations between the planned and achieved positions of anatomical landmarks and plate positions are measured in millimeters and degrees. Measurements are performed by the researcher and verified by the main supervisor.

Clinical follow-up is conducted at 1 week, 1 month, 3 months, 6 months to assess wound healing, facial symmetry, ocular function, mouth opening, and postoperative complications, including infection, nerve paresthesia, malunion, and non-union. A follow-up CT scan (T2) is planned at 6 months to evaluate bone healing and fixation stability, including any signs of loosening or displacement. Patient satisfaction is assessed using a Visual Analog Scale (VAS) ranging from 0 to 10.

Study Type

Interventional

Enrollment (Estimated)

8

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

      • Cairo, Egypt
        • department of oral and maxillofacial surgery, faculty of dentistry, Cairo university

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Patients diagnosed with Zygomatico-maxillary complex fractures requiring surgical intervention.
  • Patients aged 18 years or older.
  • Patients willing to provide informed consent and comply with follow-up protocols.
  • Patients with adequate bone quality and quantity for stable fixation.

Exclusion Criteria:

  • Patients with comminuted ZMC fractures that preclude the use of custom-made guides based on mirroring the contra lateral side.
  • Patients with pre-existing facial deformities or asymmetries that would interfere with accurate assessment of fracture reduction.
  • Patients with systemic diseases or conditions that contraindicate elective surgery or impair bone healing (e.g., uncontrolled diabetes, severe osteoporosis, active malignancy, and immunosuppression).
  • Patients on medications affecting bone metabolism (e.g., long-term corticosteroids, bisphosphonates). Patients with active infections in the maxillofacial region.
  • Pregnant or lactating women.
  • Patients with psychiatric disorders or unrealistic expectations.
  • Patients who are unable to undergo CT scans or follow post-operative instructions.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Virtual Planning and Customized Plates

Patients with ZMC fractures undergoing surgical treatment using 3D virtual planning and patient-specific titanium plates.

A 3D-printed positioning guide designed through virtual surgical planning to assist in the accurate reduction of ZMC fractures.

Other Names:
  • positioning guide

A custom-fabricated titanium plate designed to fit the patient's specific anatomy for rigid fixation of ZMC fractures.

Other Names:
  • customised plate

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Accuracy of Fracture Reduction
Time Frame: one week postoperative

Evaluation of the accuracy of fracture reduction achieved using the positioning guide and customized titanium plate. This will be assessed by superimposing the post-operative computed tomography (CT) scans onto the pre-operative virtual surgical plan. The difference will be reported as linear deviation, measured in millimeters (mm).

one week postoperative

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Fixation stability
Time Frame: 6 months postoperatively

Measured in millimeters by comparing the 6-month follow-up CT to the immediate postoperative CT to check for hardware or bone displacement.

6 months postoperatively
Patient satisfaction
Time Frame: 6 months postoperatively

Evaluation of the patient's overall satisfaction with the functional and aesthetic outcomes of the procedure. This will be assessed using a Visual Analog Scale (VAS) ranging from 0 to 10, where 0 indicates "completely dissatisfied" and 10 indicates "completely satisfied". The reported value will be the numerical score on this scale

6 months postoperatively

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Study Director: Prof. Ramy Ragab Elbialy, prof. of maxillofacial surgery, Department of Oral and maxillofacial surgery,Faculty of dentistry, Cairo university
  • Study Director: Dr. Mohamed Ali Zain Elabden, lecturer of maxillofacial surg, Department of Oral and maxillofacial surgery, Faculty of dentistry, Cairo university

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

December 18, 2025

Primary Completion (Estimated)

December 1, 2026

Study Completion (Estimated)

September 1, 2027

Study Registration Dates

First Submitted

April 29, 2026

First Submitted That Met QC Criteria

May 19, 2026

First Posted (Actual)

May 27, 2026

Study Record Updates

Last Update Posted (Actual)

November 4, 2026

Last Update Submitted That Met QC Criteria

November 1, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • OMFS3319

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.