Post-market European & Asian Registry to Evaluate the Minos™ Stent-Graft and Delivery System in Abdominal Aortic Aneurysm Treatment (PEARL)
A Prospective Multi-centre Observational Real-world Post-market European & Asian Registry With Low-profile Minos™ Abdominal Aortic Stent Graft
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Contacts and Locations
Study Contact
Study Contact
- Name: Maggie Shen, MD MSc
- Phone Number: 00441235750800
- Email: maggie.shen@endovastec-lm.com
Study Contact Backup
- Name: Anne Woodman
- Phone Number: 00441235750800
- Email: anne.woodman@endovastec-lm.com
Study Locations
-
-
-
Beijing, China, 100037
- Recruiting
- Fuwai Hospital
-
Principal Investigator:
- Chang Shu
-
-
Gansu
-
Lanzhou, Gansu, China, 730030
- Recruiting
- The Second Hospital of Lanzhou University
-
Principal Investigator:
- Dong Zhou
-
-
Guangdong
-
Meizhou, Guangdong, China, 514031
- Recruiting
- Meizhou People's Hospital
-
Principal Investigator:
- Cunren Li
-
Shenzhen, Guangdong, China, 518053
- Recruiting
- The University of Hong Kong - Shenzhen Hospital
-
Principal Investigator:
- Minxin Wei
-
-
Hunan
-
Changsha, Hunan, China, 410002
- Recruiting
- Hunan Provincial People's Hospital
-
Principal Investigator:
- Qing Wang
-
Xiangtan, Hunan, China, 411100
- Recruiting
- Xiangtan Central Hospital
-
Principal Investigator:
- Zhihong Fang
-
Yueyang, Hunan, China, 414000
- Recruiting
- Yueyang Central Hospital
-
Principal Investigator:
- Yi You
-
-
Shandong
-
Zibo, Shandong, China, 255024
- Recruiting
- Zibo Central Hospital
-
Principal Investigator:
- Xinming Yu
-
-
Tianjin Municipality
-
Binhai, Tianjin Municipality, China, 300457
- Recruiting
- Teda International Cardiovascular Hospital
-
Principal Investigator:
- Xuedong Li
-
-
Yunnan
-
Kunming, Yunnan, China, 650051
- Recruiting
- Kunming Yan'an Hospital
-
Principal Investigator:
- Huanjun Chen
-
-
-
-
-
Münster, Germany, 48149
- Recruiting
- Universitätsklinikum Münster (UKM)
-
Contact:
- Jana Ebing
- Phone Number: 00492518351717
- Email: vital@ukmuenster.de
-
Principal Investigator:
- Alexander Oberhuber, Dr. med. univ.
-
-
Allgäu
-
Immenstadt im Allgäu, Allgäu, Germany, 87439
- Recruiting
- Klinikverbund Allgäu
-
Contact:
- Roland Tines
- Phone Number: +49083239108909
- Email: Roland.Tines@klinikverbund-allgaeu.de
-
Principal Investigator:
- Roland Tines
-
-
-
-
-
Thessaloniki, Greece, GR54635
- Recruiting
- "G. Gennimatas" Thessaloniki General Hospital
-
Contact:
- Georgios A. Pitoulias
- Phone Number: 00302310992564
- Email: pitoulias@yahoo.com
-
Principal Investigator:
- Georgios A. Pitoulias, MD, PhD
-
-
-
-
-
Brescia, Italy, 25123
- Not yet recruiting
- Azienda Socio Sanitaria Territoriale degli Spedali Civili di Brescia (ASST Spedali Civili di Brescia)
-
Contact:
- Dipartimento di Chirurgia dell'ASST Spedali Civili di Brescia
- Phone Number: 0039303995612
- Email: chirurgia.vascolare@asst-spedalicivili.it
-
Principal Investigator:
- Luca Bertoglio
-
-
-
-
-
Rotterdam, Netherlands, 3015 GD
- Recruiting
- Erasmus MC
-
Principal Investigator:
- Hence Verhagen, MD, PhD
-
Contact:
- Emmy Muller-Sloof, PhD
- Phone Number: 0031107040704
- Email: e.muller-sloof@erasmusmc.nl
-
-
-
-
Catalonia
-
Girona, Catalonia, Spain, 17007
- Not yet recruiting
- Hospital Universitari de Girona Doctor Josep Trueta
-
Contact:
- Omar Andrés Navarro, MD, PhD
- Phone Number: 0034972940294
- Email: cirvasc@gmail.com
-
Contact:
-
Principal Investigator:
- Omar Andrés Navarro, MD, PhD
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Sampling Method
Study Population
Description
Inclusion Criteria:
- Diagnosis of infrarenal abdominal aortic aneurysm
- Plan to treat with Minos Abdominal Aortic Stent-Graft and Delivery System
- Voluntary participation and completion of Informed Consent Form, with willingness to participate in follow-up to 5 years post-procedure
Exclusion Criteria:
- Subjects in whom use of the Minos™ Abdominal Aortic Stent-Graft and Delivery System is contraindicated, as follows:
- Severe stenosis or calcification near the aneurysm, leading to difficulty in achieving apposition of vessel wall and stent graft.
- Difficult access due to severe stenosis or tortuosity in the iliac artery or femoral artery.
- Subjects with ruptured aneurysm or acute aneurysm.
- Subjects with an infectious aneurysm.
- Those who are allergic to contrast agents or unable to tolerate contrast agents due to renal insufficiency.
- Patients with severe coagulation disorder and/or high risk of postoperative hemorrhage.
- Aneurysmal neck angulation greater than 60°.
- Patients with blood supply to vital organs originating from the aneurysmal sac.
- Patients with other comorbidities and whose life expectancy does not exceed one year.
- Subjects with connective tissue diseases, such as Marfan syndrome.
- Minors and pregnant women.
- Subjects who are allergic to nitinol.
- Subjects who are considered not suitable for treatment with stent graft.
Study Plan
How is the study designed?
Design Details
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
PEARL participants
All subjects to be treated with Minos™ Abdominal Aortic Stent-Graft and Delivery System who meet the criteria for inclusion in the PEARL study and voluntarily consent to participate.
|
Treatment of subjects diagnosed with abdominal aortic aneurysm using the low-profile Minos Abdominal Aortic Stent-Graft and Delivery System.
Follow up as per institutional standard of care.
|
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Technical success rate at 12 months
Time Frame: 12 months
|
Technical success at 12 months is defined as accurate positioning of stent graft, normal stent shape, no distortion, bending, stenosis and occlusion, and no accidental coverage of internal iliac artery or visceral artery, the absence of aneurysm rupture, continuous type I and III endoleaks after operation, aneurysm enlargement (aneurysm diameter increased by more than 5mm), secondary intervention due to endoleak, stent occlusion or migration, including open surgery and endovascular surgery.
Expected secondary interventions will not be included in the analysis.
|
12 months
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Incidence of major adverse events at 30 days
Time Frame: 30 days
|
30 days
|
|
|
Immediate technical success
Time Frame: within 24 hours post-implantation
|
Immediate technical success is measured as successful introduction and withdrawal of stent graft and delivery system, with accurate positioning of stent graft, normal stent shape, no distortion, bending, stenosis and occlusion, and no accidental coverage of internal iliac artery or visceral artery.
|
within 24 hours post-implantation
|
|
Incidence of successful aneurysm treatment at 2-5 years
Time Frame: Years 2-5 post-implantation
|
Successful aneurysm treatment during the follow-up period of 2-5 years is defined as accurate positioning of stent graft, normal stent shape, no distortion, bending, stenosis and occlusion, and no accidental coverage of internal iliac artery or visceral artery, the absence of aneurysm rupture, continuous type I and III endoleaks after operation, aneurysm enlargement (aneurysm diameter increased by more than 5mm), secondary intervention due to endoleak, stent occlusion or migration, including open surgery and endovascular surgery.
|
Years 2-5 post-implantation
|
|
All-cause mortality up to 5 years post-procedure
Time Frame: From implantation to the end of follow up at 5 years
|
From implantation to the end of follow up at 5 years
|
|
|
Aortic aneurysm related mortality up to 5 years post-procedure
Time Frame: From implantation to the end of follow up at 5 years
|
From implantation to the end of follow up at 5 years
|
|
|
Secondary intervention rates up to 5 years post-procedure
Time Frame: From implantation to the end of follow up at 5 years
|
Secondary intervention rates up to 5 years after TEVAR are measured by tracking all subsequent open and endovascular procedures required to treat device-related or aortic complications.
This includes Open surgery: performed at any time to address a failure of endovascular treatment due to failure of stent implantation or placement, complications or other clinical conditions, or after the initial success of endovascular treatment, and Secondary endovascular intervention: any intravascular surgical intervention performed to resolve complications such as endoleak, aneurysm expansion, stent occlusion, stent migration and stent defect after the implantation of Minos™ system.
|
From implantation to the end of follow up at 5 years
|
|
Aneurysm diameter and variation in aneurysm diameter from 30 days to 5 years post-procedure
Time Frame: From 30 days post-implantation until end of follow up at 5 years
|
From 30 days post-implantation until end of follow up at 5 years
|
|
|
Incidence of type I and type III endoleaks from 30 days to 5 years post-procedure
Time Frame: From 30 days post-implantation until end of follow up at 5 years
|
From 30 days post-implantation until end of follow up at 5 years
|
|
|
Incidence rate of stent migration, fracture, stenosis, occlusion and distortion from 30 days to 5 years post-procedure
Time Frame: From 30 days post-implantation until end of follow up at 5 years
|
From 30 days post-implantation until end of follow up at 5 years
|
Collaborators and Investigators
Sponsor
Sponsor
Investigators
Investigators
- Study Director: Jing Wang, Shanghai MicroPort Endovascular MedTech(Group)Co., Ltd
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- PMCF-2020-12
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.