Multicentre Evaluation of Spinal Bone Pathologies Using Zero Echo Time (ZTE) Pseudo-CT MRI Sequences: a Clinical Implementation Study (MULTILUMBAR)

Innovative sequences known as "pseudo-CT"-such as Ultrashort Echo Time (UTE) and Zero Echo Time (ZTE)-enable good visualization of mineralized bone. These new sequences appear to enhance MRI performance in the detection of fractures, spondylolysis, and other bone abnormalities.

We would like to offer patients referred for a CT scan due to lumbar spine bone pathology the option of undergoing an MRI study, in order to compare the performance of the two techniques.

Study Overview

Status

Recruiting

Conditions

Intervention / Treatment

Detailed Description

Magnetic resonance imaging (MRI) is the gold-standard modality for examining the bone marrow and soft tissues of the spine, thanks to its excellent contrast resolution. It enables precise visualization of the intervertebral discs, nerve roots, and spinal cord. However, its ability to visualize bone mineral remains limited due to the rapid decay of the T2 signal and the inability of conventional sequences to capture signals from tissues with very short relaxation times. Consequently, assessing bone structures-such as cortical or trabecular bone, osteophytes, or fractures-remains challenging, particularly in cases of complex pathologies.

Innovative sequences known as "pseudo-CT" sequences-such as Ultrashort Echo Time (UTE) and Zero Echo Time (ZTE)-enable the capture of signals from tissues with very short T2 relaxation times and provide good visualization of mineralized bone. These new sequences appear to enhance MRI performance in the detection of fractures, spondylolysis, and other bone abnormalities.

Despite the promising potential of "pseudo-CT" sequences, studies comparing them to conventional CT and MRI sequences remain limited, as do data regarding their overall clinical benefit. Further research is therefore needed to evaluate their diagnostic value, their ability to improve patient management, and their potential to reduce the need for other imaging examinations.

Study Type

Interventional

Enrollment (Estimated)

100

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Contact Backup

Study Locations

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Adults requiring a CT scan as part of their clinical assessment for lumbar spine imaging who also provide informed consent to participate in the study.
  • Patients presenting with acute or chronic low back pain and requiring a CT scan for diagnostic purposes.

Exclusion Criteria:

  • Contraindications to MRI, such as pacemakers, metal implants, severe claustrophobia, or pregnancy
  • Spinal surgery within the last six months.
  • Patients who cannot or do not wish to provide informed consent.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: All patients

Each patient has a lumbar spine CT scan scheduled as part of their clinical follow-up. We are adding a lumbar spine MRI for the purposes of the study.

Lumbar spine MRI using innovative sequences known as "pseudo-CT," enabling the capture of signals from tissues with very short T2 relaxation times and providing good visualization of mineralized bone.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
sensitivity and specificity of pseudo-CT MRI
Time Frame: One MRI of 30 min

To evaluate the sensitivity and specificity of pseudo-CT MRI for the detection of bone lesions.

One MRI of 30 min

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Frédéric E Lecouvet, MD-PhD, Cliniques universitaires Saint-Luc- Université Catholique de Louvain

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Actual)

April 15, 2026

Primary Completion (Estimated)

March 30, 2027

Study Completion (Estimated)

March 30, 2027

Study Registration Dates

First Submitted

September 21, 2026

First Submitted That Met QC Criteria

September 21, 2026

First Posted (Actual)

September 28, 2026

Study Record Updates

Last Update Posted (Actual)

September 28, 2026

Last Update Submitted That Met QC Criteria

September 21, 2026

Last Verified

September 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • 2025/05MAI/177

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.