The Effect of Catheter Size on the Efficacy of Ultralow-flow Extracorporeal Carbon Dioxide Removal System in Acute Respiratory Distress Syndrome (Cath-COR)

October 5, 2026 updated by: Nattachai Srisawat ,M.D., Chulalongkorn University

The Effect of Catheter Size on the Efficacy of Ultralow-flow Extracorporeal Carbon Dioxide Removal System in Acute Respiratory Distress Syndrome: a Pilot Randomized Controlled Trial

This pilot randomized controlled trial will evaluate whether catheter size affects the efficacy and performance of ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) in mechanically ventilated adults with acute respiratory distress syndrome (ARDS) and hypercapnic respiratory acidosis. Participants will be randomly assigned to receive ECCO₂R using a 12F, 13F, or 15F catheter. The primary outcome is the percentage change in PaCO₂ from baseline during ECCO₂R. Secondary outcomes include achievement and time to correction of hypercapnic respiratory acidosis, changes in PaO₂, circuit lifespan, maximum blood flow, and device- and patient-related complications.

Study Overview

Status

Not yet recruiting

Conditions

Intervention / Treatment

Detailed Description

Acute respiratory distress syndrome (ARDS) may require lung-protective mechanical ventilation to reduce ventilator-induced lung injury. However, limiting tidal volume, driving pressure, plateau pressure, respiratory rate, and mechanical power may result in hypercapnia and respiratory acidosis in some patients.

Ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) may facilitate carbon dioxide removal while allowing maintenance of a lung-protective or ultra-protective ventilatory strategy. Compared with conventional high-flow extracorporeal carbon dioxide removal, ultra-low-flow ECCO₂R can be performed using smaller vascular catheters.

The efficacy of ultra-low-flow ECCO₂R may be influenced by catheter size because catheter diameter affects vascular resistance and achievable blood flow through the extracorporeal circuit. However, the optimal catheter size for achieving effective carbon dioxide removal while minimizing catheter-related risks remains uncertain.

This study is a prospective, randomized, three-arm pilot study. Adult patients with ARDS and hypercapnic respiratory acidosis who meet predefined criteria despite lung-protective mechanical ventilation will be randomly assigned to receive ultra-low-flow ECCO₂R using a 12F, 13F, or 15F catheter.

Participants will undergo ECCO₂R for a minimum of 72 hours or until predefined criteria for discontinuation are met. Blood flow will initially be set within the protocol-defined range and increased incrementally according to PaCO₂ response and hemodynamic safety parameters.

The study will evaluate the effect of catheter size on carbon dioxide removal, correction of hypercapnic respiratory acidosis, oxygenation, circuit lifespan, maximum blood flow, and patient- and device-related complications.

Study Type

Interventional

Enrollment (Estimated)

30

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Locations

    • Bangkok
      • Bangkok, Bangkok, Thailand, 10330
        • Chulalongkorn university
        • Contact:
        • Contact:
        • Principal Investigator:
          • Nattachai Srisawat, MD, PhD, Professor
        • Sub-Investigator:
          • Phruet Soipetkasem, MD
        • Sub-Investigator:
          • Nattha Lumlertgul, MD, PhD
        • Sub-Investigator:
          • Sadudee Peerapornratana, MD
        • Sub-Investigator:
          • Pongthep Theerawit, MD, Assoc. Prof.

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

Participants must meet all of the following criteria:

  1. Age ≥18 years.

  2. Acute respiratory distress syndrome (ARDS), mild to moderate severity, with a PaO₂/FiO₂ ratio of 100-300 while receiving PEEP ≥5 cmH₂O, after initiation of mechanical ventilation within the preceding 72 hours.

  3. Hypercapnic respiratory acidosis, defined by PaCO₂ >60 mmHg and/or arterial blood gas pH <7.25 due to respiratory acidosis despite mechanical ventilation exceeding the protocol-defined lung-protective strategy, characterized by one or more of the following:

    • Driving pressure >15 cmH₂O;
    • Plateau pressure >27 cmH₂O;
    • Tidal volume >6 mL/kg predicted body weight; or
    • Mechanical power >17 J/min associated with respiratory rate >25 breaths/min.

Exclusion Criteria:

  • Severe shock that is preload non-responsive and requires norepinephrine >1 µg/kg/min.
  • Acute brain injury or cerebral edema, increased intracranial pressure, status epilepticus, intracerebral hemorrhage, or acute ischemic stroke.
  • Pregnancy.
  • Morbid obesity with BMI >40 kg/m².
  • Chronic respiratory acidosis.
  • End-stage cancer patients.
  • Coagulation disorders, defined as a platelet count of less than 10,000 cells/mm3 or an INR greater than 3.
  • Patients undergoing targeted temperature management for 24 hours after return of spontaneous circulation.
  • End-stage renal disease (ESRD) patients with a blood urea nitrogen (BUN) level greater than 60 mg/dL.
  • Patients or legal representatives who do not consent to participation.
  • Patients with an indication for ECMO according to the EOLIA trial criteria, specifically a PF ratio < 50 mmHg more than 3 hours or a PF ratio < 80 mmHg more than 6 hours.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Ultralow-flow extracorporeal carbon dioxide removal system

Participants randomized to receive ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) using a 12 French (12F) catheter

Participants randomized to receive ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) using a 13 French (13F) catheter

Participants randomized to receive ultra-low-flow extracorporeal carbon dioxide removal (ECCO₂R) using a 15 French (15F) catheter

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Percentage Change in PaCO₂ From Baseline
Time Frame: Baseline and 1, 6, 12, 24, 48, and 72 hours after initiation of ECCO₂R.

Percentage change in arterial partial pressure of carbon dioxide (PaCO₂) from baseline after initiation of ultra-low-flow ECCO₂R.

Unit of Measure: Percent (%)

Baseline and 1, 6, 12, 24, 48, and 72 hours after initiation of ECCO₂R.

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Percentage of Participants Achieving Correction of Hypercapnic Respiratory Acidosis
Time Frame: 1, 6, 12, 24, 48, and 72 hours after using a lung protective strategy under ECCO2R

Percentage of achievement (% of achievement) in resolving hypercapnic respiratory acidosis (PaCO2 < 50 mmHg and pH>7.30) from hour 0 in acute respiratory distress syndrome (ARDS) patients ventilated using a lung protective strategy with ECCO2R, evaluated for each catheter size at 1, 6, 12, 24, 48, and 72 hours.

1, 6, 12, 24, 48, and 72 hours after using a lung protective strategy under ECCO2R
Time to achievement (hours) in resolving hypercapnic respiratory acidosis
Time Frame: From using a lung protective strategy under ECCO₂R through 72 hours.

Time to achievement (hours) in resolving hypercapnic respiratory acidosis from hour 0 in acute respiratory distress syndrome (ARDS) patients ventilated using a lung protective strategy with ECCO2R, evaluated for each catheter size.

From using a lung protective strategy under ECCO₂R through 72 hours.
Change in PaO₂/FiO2 ratio From Baseline
Time Frame: 1, 6, 12, 24, 48, and 72 hours.

Change in PaO₂/FiO2 ratio from baseline following initiation of ECCO₂R.

1, 6, 12, 24, 48, and 72 hours.
Circuit Lifespan
Time Frame: From initiation of ECCO₂R through 72 hours.

Duration of use of the ECCO₂R circuit from initiation until circuit replacement or discontinuation.

From initiation of ECCO₂R through 72 hours.
Maximum Blood Flow Achieved During ECCO₂R
Time Frame: During the ECCO₂R treatment period, up to 72 hours.

Maximum blood flow rate achieved during ECCO₂R while maintaining MAP >65 mmHg and protocol-defined circuit pressure safety criteria.

During the ECCO₂R treatment period, up to 72 hours.
ECCO₂R-Related Complications
Time Frame: From initiation of ECCO₂R through 72 hours.

Occurrence of complications including catheter-related bleeding, anemia requring blood transfusion, hemolysis, catheter infection, circuit thrombosis, hemodynamic instability, and other patient- or device-related complications.

From initiation of ECCO₂R through 72 hours.

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

December 1, 2026

Primary Completion (Estimated)

December 30, 2029

Study Completion (Estimated)

December 30, 2029

Study Registration Dates

First Submitted

September 29, 2026

First Submitted That Met QC Criteria

September 29, 2026

First Posted (Actual)

October 5, 2026

Study Record Updates

Last Update Posted (Actual)

October 8, 2026

Last Update Submitted That Met QC Criteria

October 5, 2026

Last Verified

October 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • IRB. No. 0053/68

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

product manufactured in and exported from the U.S.

Yes

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.