Eye Covering and White Noise During Nasogastric Tube Insertion in Preterm Infants

November 9, 2026 updated by: Ayşegül Şimşek, Marmara University

The Effect of Eye Covering and White Noise During Nasogastric Tube Insertion on Comfort, Pain, Stress, and Physiological Parameters in Preterm Infants

This study aims to evaluate the effects of eye covering and white noise during nasogastric tube insertion on comfort, pain, stress, and physiological parameters in preterm infants. A total of 90 preterm infants will be randomly assigned to one of three groups: eye covering, white noise, or combined eye covering and white noise. Comfort, pain, stress, heart rate, respiratory rate, and oxygen saturation will be assessed before, during, and after nasogastric tube insertion.

Study Overview

Status

Not yet recruiting

Conditions

Intervention / Treatment

Detailed Description

Preterm infants are more sensitive to invasive procedures and environmental stimuli performed in neonatal intensive care units because their physiological and neurological systems are not yet fully mature. Nasogastric tube placement is one of the procedures frequently performed on these infants and can cause pain, stress, behavioral distress, and changes in physiological parameters. Therefore, it is important to evaluate non-pharmacological developmental care interventions aimed at reducing pain and stress, increasing comfort, and supporting physiological stability during the procedure. Eye-covering is a non-pharmacological intervention designed to reduce environmental light stimuli. White noise, on the other hand, aims to support the infant's calming and reduce sensitivity to environmental sounds by providing a continuous auditory stimulus without sudden changes. However, evidence regarding the effects of applying these two interventions-separately or in combination-during nasogastric tube placement on preterm infants' comfort, pain, stress levels, and physiological parameters is limited.

This study is a single-center, three-arm, randomized controlled trial planned to be conducted in the neonatal intensive care unit of a university hospital. A total of 90 preterm infants are planned to be included in the study, and the infants will be randomly assigned to three groups in a 1:1:1 ratio. Randomization will be performed using an online randomization program.

Infants in the first group will be fitted with a phototherapy eye mask 15 minutes before nasogastric tube placement, and the eye mask will be kept in place during the procedure and for 15 minutes afterward. Infants in the second group will begin listening to white noise 15 minutes before nasogastric tube placement, and the white noise will continue during the procedure and for 15 minutes afterward. White noise will be administered at a sound level of 40-60 dB via a pre-recorded audio file, and the sound source will be positioned approximately 30-50 cm away from the infant. For infants in the third group, both the eye-covering and white noise interventions will be administered simultaneously. Both interventions will begin 15 minutes before nasogastric tube placement and will continue throughout the procedure and for 15 minutes afterward. In all groups, the infants' comfort, pain, and stress levels, as well as their physiological parameters, will be assessed at three different time points: 5 minutes before the procedure, during the procedure, and 5 minutes after the procedure. Comfort levels will be determined using the Neonatal Comfort Behavior Scale (COMFORTneo), while pain and stress levels will be assessed using the ALPS-NEO Neonatal Pain and Stress Assessment Scale. Physiological assessments will include measurements of heart rate, respiratory rate, and oxygen saturation.

Nasogastric tube placement will be performed by healthcare professionals working in the neonatal intensive care unit in accordance with the infant's clinical needs. No additional invasive procedures beyond clinical care requirements will be performed on the infants as part of this study. To minimize assessment bias, comfort, pain, and stress assessments will be conducted by neonatal nurses who are not part of the research team; physiological parameters will be recorded by the researcher. The study aims to compare the effects of eye-covering and white noise-both individually and in combination-on preterm infants' comfort, pain, stress levels, and physiological responses. The findings are expected to contribute to the scientific evidence regarding non-pharmacological, developmentally-based nursing interventions that can be used during nasogastric tube placement in neonatal intensive care units.

Study Type

Interventional

Enrollment (Estimated)

90

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Study Locations

      • Istanbul, Turkey (Türkiye)
        • Bağcılar Training and Research Hospital
        • Principal Investigator:
          • Aysegul Simsek, PhD
        • Contact:

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

3 days and older (Child, Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • Written and verbal parental consent for participation
  • Gestational age between 32 and 36 weeks
  • Birth weight of 1500 g or greater
  • Apgar score of 6 or greater at 1 and 5 minutes
  • Postnatal age of 3 days or older
  • Hospitalization in the neonatal intensive care unit for more than 24 hours
  • No sedation
  • No procedures such as peripheral intravenous catheter insertion, blood sampling, or aspiration within 1 hour before enrollment
  • Clinically stable condition

Exclusion Criteria:

  • Central nervous system problems such as intracranial hemorrhage, seizures, or hypertonia
  • Congenital or genetic anomalies
  • Receiving phototherapy
  • Respiratory distress requiring oxygen support
  • Receiving mechanical ventilation

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Other
  • Allocation: Randomized
  • Interventional Model: Parallel Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: Eye Covering

Preterm infants will receive eye covering beginning 15 minutes before nasogastric tube insertion. The eye covering will remain in place during the procedure and for 15 minutes after the procedure.

Eye covering will be applied 15 minutes before nasogastric tube insertion and will remain in place during the procedure and for 15 minutes after the procedure.

Experimental: White Noise

Preterm infants will receive white noise at 45 dB beginning 15 minutes before nasogastric tube insertion. White noise will continue during the procedure and for 15 minutes after the procedure.

White noise at 45 dB will be started 15 minutes before nasogastric tube insertion and will continue during the procedure and for 15 minutes after the procedure.

Experimental: Eye Covering and White Noise

Preterm infants will receive both eye covering and white noise beginning 15 minutes before nasogastric tube insertion. Both interventions will continue during the procedure and for 15 minutes after the procedure.

Eye covering and white noise at 45 dB will be applied together beginning 15 minutes before nasogastric tube insertion. Both interventions will continue during the procedure and for 15 minutes after the procedure.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Neonatal Comfort Level Assessed Using the COMFORTneo Scale
Time Frame: 5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion

The scale was developed to assess the behavior of newborns in the intensive care unit without relying on physiological parameters. COMFORTneo is a Likert-type scale consisting of six parameters: alertness, calmness/agitation, respiratory response, crying, body movements, facial tension, and muscle tone. The lowest possible score on the Neonatal Comfort Behavior Scale is 6, and the highest is 30. Higher scores indicate that the infant is uncomfortable and requires interventions to ensure comfort. Additionally, on Numerical Rating Scales, scores between 4 and 6 indicate moderate pain and distress, while scores between 7 and 10 indicate severe pain and distress. The validity and reliability study of the scale in Turkish was conducted in 2014. In the Turkish validity and reliability study, the scale's Cronbach's alpha coefficient was reported as 0.85.

5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Heart Rate
Time Frame: 5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion

Heart rate will be measured using a pulse oximeter and recorded as beats per minute.

5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion
Respiratory Rate
Time Frame: 5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion

Respiratory rate will be measured and recorded as breaths per minute.

5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion
Oxygen Saturation
Time Frame: 5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion

Peripheral oxygen saturation will be measured using a pulse oximeter and recorded as a percentage.

5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion
Neonatal Pain and Stress Assessed Using the ALPS-Neo Scale
Time Frame: 5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion

The scale was developed to assess pain and stress in preterm and term newborns, and its Cronbach's alpha coefficient has been reported as 0.95. The scale's validity and reliability in Turkish have been established. ALPS-Neo is a 3-point Likert-type scale consisting of five items: the newborn's facial expression, breathing pattern, limb tone, hand and foot movements, and activity level. Measurements are made through observation. As the score increases, the level of pain and stress increases. According to the assessment results, a score of 0-2 indicates the absence of pain and stress and that no intervention is required. A score of 3-5 indicates the presence of moderate pain and stress, while scores of 5 or higher indicate the presence of severe pain and stress.

5 minutes before, during procedure, and 5 minutes after nasogastric tube insertion

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Investigators

  • Principal Investigator: Aysegul Simsek, PhD, Marmara University

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

November 1, 2026

Primary Completion (Estimated)

November 1, 2027

Study Completion (Estimated)

November 1, 2027

Study Registration Dates

First Submitted

October 29, 2026

First Submitted That Met QC Criteria

November 3, 2026

First Posted (Actual)

November 4, 2026

Study Record Updates

Last Update Posted (Actual)

November 12, 2026

Last Update Submitted That Met QC Criteria

November 9, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • AS-NICU-NG-2026-01

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.