A Crossover Comparison of Conventional and Digital Impression Techniques
The study was aimed to compare both digital and conventional impression techniques by having the same patient undergo both impression techniques in the maxilla.
Study Overview
Status
Status
Conditions
Conditions
Detailed Description
Objectives:
Primary:
• To determine which impression method patients, prefer: a traditional impression or a digital impression using an intraoral scanner.
Secondary:
- To validate the questionnaire used.
- To evaluate, at the clinical level, which procedure has a faster and smoother workflow.
Methodology:
Study type: observational study. Sample size: 112.
Inclusion criteria:
- Patients over 18 years of age.
- Patients who require impressions for clinical study and/or prosthetic work.
Exclusion criteria:
- Patients with allergies to the materials used.
- Patients with epilepsy.
- Edentulous patients.
Study subjects will be from the patients of the master's degree in Oral Surgery and Oral and Facial Implantology at the University Dental Clinic of CEU Cardenal Herrera University in Valencia, who will be undergoing treatment in the department and getting the impressions taken as part of the standard protocol of the department. Participants willing to participate will have to meet the established inclusion and exclusion criteria.
A crossover observational study is established to determine which impression method the patient prefers: the use of the traditional impression method or the use of an intraoral scanner. Both techniques will be applied to each patient in the maxilla. The technique used first will be following an alternating order. The patient will be asked to complete a questionnaire following the application of each procedure (Annex 1).
Variables:
- Pain level.
- Discomfort from temperature.
- Discomfort from pressure.
- Discomfort from nausea.
- Satisfaction from duration.
- Willingness to repeat.
- Level of satisfaction.
Statistical Analysis:
Data analysis will be performed using Python 3.13.5, with NumPy 2.3.5, SciPy 1.17.0, and statsmodels 0.14.6. Descriptive statistics will be calculated for all variables. Continuous variables will be presented as means and standard deviations. Comparisons between digital and conventional impression techniques will be performed using paired Student's t-tests, with statistical significance set at p < 0.05.
Study Type
Study Type
Enrollment (Actual)
Enrollment
Contacts and Locations
Study Locations
-
-
Alfara Del Patriarca
-
Valencia, Alfara Del Patriarca, Spain, 46115
- UCH CEU Dental Clinic
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Sampling Method
Study Population
Local patients who attended the UCH CEU dental clinic department of oral surgery.
Description
Inclusion Criteria:
- Age ≥ 18 years.
- Indication for dental impressions.
Exclusion Criteria:
- Allergy to impression materials.
- History of epilepsy.
- Completely edentulous patients.
Study Plan
How is the study designed?
Design Details
- Observational Models: CASE_CROSSOVER
- Time Perspectives: CROSS_SECTIONAL
Number of groups / cohorts
Cohorts and Interventions
Group / CohortGroup / Cohort |
|---|
|
Dual technique group
The participant received both digital and conventional dental impression techniques. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Time Frame |
|---|---|
|
Pain During Dental Impressions Measured Using a 0-10 Visual Analog Scale
Time Frame: Day 1, immediately following each impression procedure (conventional and digital).
|
Day 1, immediately following each impression procedure (conventional and digital).
|
|
Temperature Discomfort During Dental Impressions Measured Using a 0-10 Visual Analog Scale
Time Frame: Day 1, immediately following each impression procedure (conventional and digital).
|
Day 1, immediately following each impression procedure (conventional and digital).
|
|
Pressure Discomfort During Dental Impressions Measured Using a 0-10 Visual Analog Scale
Time Frame: Day 1, immediately following each impression procedure (conventional and digital).
|
Day 1, immediately following each impression procedure (conventional and digital).
|
|
Nausea During Dental Impressions Measured Using a 0-10 Visual Analog Scale
Time Frame: Day 1, immediately following each impression procedure (conventional and digital).
|
Day 1, immediately following each impression procedure (conventional and digital).
|
|
Satisfaction With Impression Procedure Duration Measured Using a 0-10 Visual Analog Scale
Time Frame: Day 1, immediately following each impression procedure (conventional and digital).
|
Day 1, immediately following each impression procedure (conventional and digital).
|
|
Willingness to Repeat the Impression Procedure Measured Using a 0-10 Visual Analog Scale
Time Frame: Day 1, immediately following each impression procedure (conventional and digital).
|
Day 1, immediately following each impression procedure (conventional and digital).
|
|
Overall Satisfaction Measured Using a 0-10 Visual Analog Scale
Time Frame: Day 1, immediately following each impression procedure (conventional and digital).
|
Day 1, immediately following each impression procedure (conventional and digital).
|
|
Participant Preference for Conventional or Digital Impression Technique Assessed Using a written categorical preference
Time Frame: Day 1, immediately following both impression procedures (conventional and digital).
|
Day 1, immediately following both impression procedures (conventional and digital).
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Actual)
Primary Completion
Study Completion (Actual)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- CEEI24/505
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.