68Ga-CAIX PET Imaging in Different Types of Tumors

November 17, 2026 updated by: Shanghai East Hospital

A Study of the Clinical Application of 68Ga-CAIX PET Imaging in Different Types of Tumors

This study aims to evaluate the clinical usefulness and safety of a new imaging tracer, gallium-68-labeled carbonic anhydrase IX (68Ga-CAIX), for positron emission tomography (PET) imaging in patients with different types of solid tumors.

Carbonic anhydrase IX (CAIX) is a protein that is often found at increased levels in certain cancers, particularly in tumors with low oxygen levels. Imaging this protein may help doctors identify and evaluate tumor lesions.

This prospective, single-center study plans to enroll approximately 100 adult patients with solid tumors. Each participant will undergo two PET scans: a conventional 18F-FDG PET scan and an investigational 68Ga-CAIX PET scan, generally within 10 days of each other.

Researchers will evaluate how well 68Ga-CAIX PET identifies primary tumors and metastatic lesions, measure tracer uptake in different tumor types, and compare its imaging findings with those of 18F-FDG PET. Available pathology and clinical follow-up information will also be collected to help interpret the imaging results.

The safety of 68Ga-CAIX will be assessed by monitoring adverse events associated with the imaging procedure. This is a diagnostic imaging study and does not involve experimental cancer treatment.

Study Overview

Status

Not yet recruiting

Conditions

Intervention / Treatment

Detailed Description

Background and Rationale

Carbonic anhydrase IX (CAIX) is a transmembrane protein involved in the regulation of cellular pH and is frequently overexpressed in hypoxic tumor microenvironments. Increased CAIX expression has been reported in several solid malignancies, particularly clear cell renal cell carcinoma, as well as certain lung, cervical, bladder, breast, and head and neck cancers. CAIX represents a promising molecular target for noninvasive tumor imaging.

Although 18F-fluorodeoxyglucose (18F-FDG) PET is widely used in oncologic imaging, its diagnostic performance may be limited in certain tumor types. The development of CAIX-targeted PET tracers may provide complementary information regarding tumor characteristics and potentially improve lesion visualization.

Study Objectives

The primary objective of this study is to evaluate the imaging characteristics and clinical feasibility of 68Ga-CAIX PET in patients with different types of solid tumors, with particular emphasis on the visualization and quantitative assessment of primary and metastatic lesions.

Secondary objectives include comparing lesion detection between 68Ga-CAIX PET and 18F-FDG PET, investigating the relationship between 68Ga-CAIX uptake and CAIX protein expression when pathological specimens are available, and evaluating the safety and feasibility of 68Ga-CAIX PET imaging.

Study Design and Procedures

This is a prospective, single-center, open-label, non-randomized, self-controlled diagnostic imaging study conducted at Shanghai East Hospital, China. Approximately 100 adult patients with solid tumors will be enrolled.

All participants will undergo both conventional 18F-FDG PET and investigational 68Ga-CAIX PET imaging. The order of the two scans will be determined by clinical scheduling and tracer availability, and both examinations are planned to be completed within a 10-day period.

For the investigational examination, participants will receive a single intravenous injection of 68Ga-CAIX, with a recommended administered activity of 3-6 mCi. PET imaging will generally be performed approximately 60 ± 10 minutes after tracer administration.

Imaging and Clinical Assessments PET images will be evaluated visually and quantitatively to characterize radiotracer uptake in primary tumors and metastatic lesions across different tumor types. Imaging assessments will include lesion location, number, size, visual positivity, maximum standardized uptake value (SUVmax), mean standardized uptake value (SUVmean), and tumor-to-background ratio (TBR).

Lesion detection using 68Ga-CAIX PET will be compared with conventional 18F-FDG PET within the same participants. When available, histopathological findings, CAIX immunohistochemical expression, and relevant clinical imaging or follow-up information will be used to support the interpretation of imaging findings.

Safety and Follow-up Participants will be monitored for adverse events during and after the investigational PET examination. Immediate safety monitoring will be performed from tracer administration until departure from the nuclear medicine department. Additional safety information will be collected during the first 1-14 days after imaging through medical record review or follow-up contact.

Relevant clinical, pathological, and imaging information will be collected approximately 6 months after the imaging examinations.

This exploratory study is intended to provide preliminary evidence regarding the clinical applicability, imaging characteristics, and safety of 68Ga-CAIX PET across different solid tumor types.

Study Type

Interventional

Enrollment (Estimated)

100

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Study Contact

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

18 years and older (Adult, Older Adult)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  1. Age ≥18 years.
  2. Clinically confirmed diagnosis of a tumor.
  3. Life expectancy of at least 3 months.
  4. Eastern Cooperative Oncology Group (ECOG) performance status ≤2.
  5. Ability and willingness to provide written informed consent.
  6. Willingness and ability to comply with the study procedures.

Exclusion Criteria:

  1. Pregnancy or breastfeeding.
  2. Severe claustrophobia.
  3. Severe medical condition that prevents the participant from undergoing further diagnostic evaluation or treatment.

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Diagnostic
  • Allocation: N/A
  • Interventional Model: Single Group Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: 68Ga-CAIX PET and 18F-FDG PET Imaging

All participants will undergo both investigational 68Ga-CAIX PET and conventional 18F-FDG PET imaging as part of a single-group, within-subject comparison study. Each participant will receive a single intravenous administration of 68Ga-CAIX (3-6 mCi), followed by PET imaging approximately 60 ± 10 minutes after injection. A conventional 18F-FDG PET scan will also be performed according to standard clinical procedures. Both examinations are planned to be completed within 10 days, with the examination order determined by clinical scheduling and tracer availability. Imaging findings will be compared to evaluate lesion detection and radiotracer uptake in primary and metastatic tumors.

Participants will receive a single intravenous injection of the investigational radiotracer 68Ga-CAIX, targeting carbonic anhydrase IX (CAIX), at a recommended administered activity of 3-6 mCi. PET imaging will be performed approximately 60 ± 10 minutes after injection. Images will be evaluated for visualization and radiotracer uptake in primary and metastatic tumor lesions, including SUVmax, SUVmean, and tumor-to-background ratio (TBR). Safety will be monitored following tracer administration.

Participants will undergo conventional 18F-FDG PET imaging according to standard clinical procedures, including fasting, blood glucose assessment, intravenous administration of 18F-FDG, and PET image acquisition. Imaging findings will be used as a within-subject comparator to evaluate lesion detection and radiotracer uptake relative to investigational 68Ga-CAIX PET. Both PET examinations are planned to be completed within 10 days, with the examination order determined by clinical scheduling and radiotracer availability.

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Number of Tumor Lesions With Positive Uptake on 68Ga-CAIX PET
Time Frame: At 68Ga-CAIX PET imaging (Day 0 to Day 10)

The number of primary and metastatic tumor lesions showing visually positive uptake on 68Ga-CAIX PET will be recorded. Each evaluated lesion will be classified as PET-positive or PET-negative based on focal, nonphysiological tracer uptake confirmed on multiplanar images. The number of PET-positive lesions will be reported separately for primary and metastatic tumor sites. The unit of measurement is the number of lesions.

At 68Ga-CAIX PET imaging (Day 0 to Day 10)
Maximum Standardized Uptake Value of Tumor Lesions on 68Ga-CAIX PET
Time Frame: At 68Ga-CAIX PET imaging (Day 0 to Day 10)

The maximum standardized uptake value (SUVmax) will be measured for each evaluable primary and metastatic tumor lesion on 68Ga-CAIX PET images. SUVmax represents the highest standardized radiotracer uptake within the lesion. Values will be summarized according to tumor type and lesion location. SUVmax is a unitless quantitative parameter.

At 68Ga-CAIX PET imaging (Day 0 to Day 10)
Mean Standardized Uptake Value of Tumor Lesions on 68Ga-CAIX PET
Time Frame: At 68Ga-CAIX PET imaging (Day 0 to Day 10)

The mean standardized uptake value (SUVmean) will be measured within the defined region or volume of interest for each evaluable primary and metastatic tumor lesion on 68Ga-CAIX PET images. SUVmean reflects the average standardized radiotracer uptake within the lesion. Values will be summarized according to tumor type and lesion location. SUVmean is unitless.

At 68Ga-CAIX PET imaging (Day 0 to Day 10)
Tumor-to-Background Uptake Ratio on 68Ga-CAIX PET
Time Frame: At 68Ga-CAIX PET imaging (Day 0 to Day 10)

The tumor-to-background ratio (TBR) will be calculated for each evaluable primary and metastatic tumor lesion using radiotracer uptake in the lesion relative to uptake in the designated background reference region. TBR values will be summarized according to tumor type and lesion location. TBR is expressed as a unitless ratio.

At 68Ga-CAIX PET imaging (Day 0 to Day 10)

Secondary Outcome Measures

Outcome Measure
Measure Description
Time Frame
Difference in Lesion Detection Rates Between 68Ga-CAIX PET and 18F-FDG PET
Time Frame: Up to 6 months after PET imaging (±2 weeks), including reference-standard assessment

The lesion detection rates of 68Ga-CAIX PET and 18F-FDG PET will be compared within the same participants. For each tracer, the detection rate will be calculated as the number of reference-standard-confirmed tumor lesions detected on PET divided by the total number of confirmed target lesions, multiplied by 100. The difference between the two detection rates will be expressed in percentage points.

Up to 6 months after PET imaging (±2 weeks), including reference-standard assessment
Correlation Between 68Ga-CAIX PET SUVmax and CAIX Immunohistochemical Expression
Time Frame: Up to 6 months after PET imaging (±2 weeks), including pathology data collection

The correlation between 68Ga-CAIX PET SUVmax and CAIX protein expression will be evaluated in tumor lesions with available tissue specimens. CAIX expression will be assessed using immunohistochemical H-score or the percentage of CAIX-positive tumor cells, as available. The association will be quantified using Pearson or Spearman correlation coefficients, as appropriate. Correlation coefficients are unitless.

Up to 6 months after PET imaging (±2 weeks), including pathology data collection
Number of Participants With Adverse Events Following 68Ga-CAIX Administration
Time Frame: From 68Ga-CAIX administration through 14 days after injection

The number of participants experiencing at least one adverse event (AE) following intravenous administration of 68Ga-CAIX will be recorded, regardless of its relationship to the investigational tracer. Adverse events will be assessed and graded according to the Common Terminology Criteria for Adverse Events version 5.0 (CTCAE v5.0). Results will be reported as the number of participants with at least one AE.

From 68Ga-CAIX administration through 14 days after injection

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Sponsor

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start (Estimated)

March 1, 2027

Primary Completion (Estimated)

December 31, 2029

Study Completion (Estimated)

December 31, 2029

Study Registration Dates

First Submitted

November 17, 2026

First Submitted That Met QC Criteria

November 17, 2026

First Posted (Actual)

November 23, 2026

Study Record Updates

Last Update Posted (Actual)

November 23, 2026

Last Update Submitted That Met QC Criteria

November 17, 2026

Last Verified

November 1, 2026

More Information

Terms related to this study

Other Study ID Numbers

  • 2026352

Plan for Individual participant data (IPD)

Plan to Share Individual Participant Data (IPD)?

NO

IPD Plan Description

Individual participant data (IPD) will not be made publicly available or routinely shared with external researchers. This is a single-center exploratory diagnostic imaging study involving sensitive clinical information and medical imaging data. To protect participant confidentiality and privacy, study data will be de-identified and securely stored, with access restricted to authorized research personnel in accordance with the approved study protocol and informed consent. Study findings may be published in aggregate form without disclosing identifiable participant information.

Drug and device information, study documents

Studies a U.S. FDA-regulated drug product

No

Studies a U.S. FDA-regulated device product

No

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.