Slow Up, Slow Down, and Wait Balloon Inflation Before Planned Drug-Coated Balloon Treatment in Patients With Coronary Artery Disease (SSW-DCB)
Slow Up, Slow Down, and Wait Strategy for Drug-Coated Balloon Treatment: A Randomized Controlled Trial of Slow Versus Routine Balloon Inflation During Preparation of De Novo Coronary Lesions to Reduce Intraprocedural Bailout Stenting
The SSW-DCB study will test whether a slow balloon inflation technique reduces the need for a stent during a coronary procedure in adults with coronary artery disease who are scheduled for drug-coated balloon treatment.
Before using a drug-coated balloon, doctors use a separate balloon to prepare the narrowed area of the artery. Participants will be assigned by chance to one of two groups, with an equal chance of joining either group. In one group, doctors will use the Slow Up, Slow Down, and Wait (SSW) technique, which involves gradually increasing the balloon pressure, holding it briefly, and then gradually releasing the pressure. In the other group, doctors will use the usual balloon inflation technique.
After preparing the artery, doctors will check whether it is suitable for treatment with a drug-coated balloon. If the artery meets the study criteria for needing a stent, a stent may be placed during the procedure. This is called bailout stenting. The main question is whether fewer participants in the SSW group need bailout stenting.
Follow-up visits or calls are planned at 1, 6, 9, and 12 months after the procedure. A repeat coronary angiogram is planned at 12 months to check the treated area. Longer-term follow-up will collect information about heart-related and bleeding events.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
SSW-DCB is a prospective, single-center, randomized superiority trial at Fuwai Hospital. The study plans to enroll 718 adults with coronary artery disease and de novo, non-left-main epicardial coronary lesions considered suitable for a drug-coated balloon (DCB) treatment strategy. Participants will be randomized in a 1:1 ratio before balloon lesion preparation. Randomization will be stratified by diabetes status, reference vessel diameter, and target lesion length.
The trial evaluates whether the pressure profile used during balloon lesion preparation affects the need for intraprocedural bailout stenting. The SSW technique uses a controlled increase in pressure, a brief hold at the target pressure, and gradual deflation. The routine technique uses a rapid increase in pressure and routine deflation. Both groups follow the same principles for balloon selection, target pressure, and escalation to a cutting or scoring balloon when needed. Procedural pressure and timing data will be recorded to assess adherence to the assigned technique.
After lesion preparation, the same protocol-defined criteria will guide whether to proceed with DCB treatment or consider bailout stenting in both groups. The primary comparison will follow the intention-to-treat principle. Follow-up analyses will also examine clinical and imaging outcomes by randomized preparation technique within cohorts defined by the treatment ultimately received, either DCB or a drug-eluting stent. Paired intravascular imaging, when available, will be reviewed by a blinded core laboratory.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Erli Zhang
- Phone Number: +86-10-88322422
- Email: ZhangErli@fuwaihospital.org
Study Locations
-
-
Beijing Municipality
-
Beijing, Beijing Municipality, China, 100037
- Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College
-
Contact:
- Erli Zhang
- Phone Number: +86-10-88322422
- Email: ZhangErli@fuwaihospital.org
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
Inclusion Criteria:
- Age 18 years or older.
- Clinical diagnosis of coronary artery disease presenting as chronic coronary syndrome or hemodynamically stable acute coronary syndrome.
- Angiographically confirmed de novo lesion in a non-left-main epicardial coronary artery meeting either of the following:
- Diameter stenosis of 70% or greater by quantitative coronary angiography (QCA).
- Diameter stenosis of 50% to 69% by QCA with functional evidence of ischemia, such as a positive fractional flow reserve (FFR) or instantaneous wave-free ratio (iFR) result, or clear evidence of ischemia based on clinical findings or noninvasive testing.
- The operator judges the target lesion suitable for a drug-coated balloon (DCB) treatment strategy.
- Coronary angiography confirms suitability for percutaneous coronary intervention (PCI) before randomization. Randomization takes place before balloon predilation.
- Provides written informed consent and agrees to undergo follow-up coronary angiography at 12 months, within a window of plus or minus 1 month.
Exclusion Criteria:
- Hemodynamic instability, such as persistent hypotension or a need for vasopressors or mechanical circulatory support.
- Left main coronary artery lesion or bifurcation lesion.
- Severe comorbidity, such as active malignancy or severe hepatic or renal failure, or inability to complete follow-up.
- Chronic total occlusion, severe calcification requiring rotational atherectomy, or severe tortuosity greater than 90 degrees in the target lesion.
- Prior stent implantation in the target vessel.
- High bleeding risk or inability to tolerate dual antiplatelet therapy.
- Life expectancy of less than 1 year.
- Pregnancy or breastfeeding.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Treatment
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Double
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: SSW Balloon Inflation
Participants assigned to this arm will undergo coronary lesion preparation using the Slow Up, Slow Down, and Wait (SSW) balloon inflation technique before planned drug-coated balloon treatment. |
During coronary lesion preparation, the operator initially inflates the balloon to unfold it, then increases pressure at 2 atmospheres per second to the target pressure. The operator holds the target pressure for 5 to 10 seconds and then releases pressure at no more than 2 atmospheres per second until it reaches zero. |
|
Active Comparator: Routine Balloon Inflation
Participants assigned to this arm will undergo coronary lesion preparation using the routine balloon inflation technique before planned drug-coated balloon treatment. |
During coronary lesion preparation, the operator increases balloon pressure rapidly and continuously to the target pressure over 3 to 5 seconds, holds the target pressure for 5 to 10 seconds, and then deflates the balloon by applying negative pressure with the inflation device. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percentage of Participants Undergoing Intraprocedural Bailout Stenting
Time Frame: During the index coronary intervention
|
The percentage of participants who receive at least one bailout stent during the index coronary intervention because the protocol-defined criteria for bailout stenting are met. |
During the index coronary intervention
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percentage of Participants Requiring Repeat Revascularization
Time Frame: Within 24 hours after the index coronary intervention
|
Percentage of participants requiring repeat revascularization within 24 hours after the index coronary intervention. |
Within 24 hours after the index coronary intervention
|
|
Percentage of Participants With Angiographic Restenosis
Time Frame: At 12 months after the index coronary intervention
|
Percentage of participants with greater than 50% diameter stenosis in the target lesion on follow-up quantitative coronary angiography. Assessed separately in participants ultimately treated with a drug-coated balloon and those ultimately treated with a drug-eluting stent. |
At 12 months after the index coronary intervention
|
|
Cumulative Incidence of Target Lesion Failure
Time Frame: From the index coronary intervention through 12 months
|
Target lesion failure is a composite of cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization. The 12-month cumulative incidence will be estimated separately in the drug-coated balloon and drug-eluting stent cohorts. |
From the index coronary intervention through 12 months
|
|
Cumulative Incidence of Cardiac Death
Time Frame: From the index coronary intervention through 12 months
|
Cardiac death is an individual component of target lesion failure and will be reported separately in the drug-coated balloon and drug-eluting stent cohorts. |
From the index coronary intervention through 12 months
|
|
Cumulative Incidence of Target Vessel Myocardial Infarction
Time Frame: From the index coronary intervention through 12 months
|
Myocardial infarction involving the target vessel is an individual component of target lesion failure and will be reported separately in the drug-coated balloon and drug-eluting stent cohorts. |
From the index coronary intervention through 12 months
|
|
Cumulative Incidence of Clinically Driven Target Lesion Revascularization
Time Frame: From the index coronary intervention through 12 months
|
Clinically driven revascularization of the target lesion is an individual component of target lesion failure and will be reported separately in the drug-coated balloon and drug-eluting stent cohorts. |
From the index coronary intervention through 12 months
|
|
Late Lumen Area Loss
Time Frame: Immediately after the index coronary intervention and at 12 months
|
The immediate post-procedure minimum lumen area minus the 12-month minimum lumen area, expressed in square millimeters. Measurements are obtained by intravascular ultrasound (IVUS) or optical coherence tomography (OCT) in the balloon-treated segment or stented segment, according to the treatment received. |
Immediately after the index coronary intervention and at 12 months
|
|
Change in Plaque Burden
Time Frame: Immediately after the index coronary intervention and at 12 months
|
The 12-month plaque burden minus the immediate post-procedure plaque burden, expressed in percentage points. Plaque burden is calculated as 100 times the difference between external elastic membrane area and lumen area, divided by external elastic membrane area. Assessed using paired intravascular imaging. |
Immediately after the index coronary intervention and at 12 months
|
|
Minimum Lumen Diameter
Time Frame: Immediately after the index coronary intervention and at 12 months
|
Minimum lumen diameter in the treated segment, measured in millimeters using paired IVUS or OCT and assessed separately in the drug-coated balloon and drug-eluting stent cohorts. |
Immediately after the index coronary intervention and at 12 months
|
|
Percent Lumen Area Stenosis
Time Frame: Immediately after the index coronary intervention and at 12 months
|
Percentage lumen area stenosis in the treated segment, assessed using paired IVUS or OCT separately in the drug-coated balloon and drug-eluting stent cohorts. |
Immediately after the index coronary intervention and at 12 months
|
|
External Elastic Membrane Area
Time Frame: Immediately after the index coronary intervention and at 12 months
|
External elastic membrane cross-sectional area in the treated segment, measured in square millimeters where assessable on paired intravascular imaging. |
Immediately after the index coronary intervention and at 12 months
|
|
Vascular Remodeling Index
Time Frame: Immediately after the index coronary intervention and at 12 months
|
Vascular remodeling index of the treated segment assessed using paired intravascular imaging, separately in the drug-coated balloon and drug-eluting stent cohorts. |
Immediately after the index coronary intervention and at 12 months
|
Other Outcome Measures
Other Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Percentage of Participants With Plaque Regression
Time Frame: Immediately after the index coronary intervention and at 12 months
|
Among participants with paired intravascular imaging, the percentage with a decrease in plaque burden of at least 5 percentage points from immediately after the index intervention to 12 months. Measurements are based on blinded core laboratory readings. |
Immediately after the index coronary intervention and at 12 months
|
|
Change in Plaque Volume
Time Frame: Immediately after the index coronary intervention and at 12 months
|
The 12-month plaque volume minus the immediate post-procedure plaque volume, expressed in cubic millimeters. This is a supportive measure of plaque regression in the paired intravascular imaging subgroup. |
Immediately after the index coronary intervention and at 12 months
|
|
Change in Percent Atheroma Volume
Time Frame: Immediately after the index coronary intervention and at 12 months
|
The 12-month percent atheroma volume minus the immediate post-procedure percent atheroma volume, expressed in percentage points. This is a supportive measure of plaque regression in the paired intravascular imaging subgroup. |
Immediately after the index coronary intervention and at 12 months
|
Collaborators and Investigators
Sponsor
Sponsor
Collaborators
Collaborators
Study record dates
Study Major Dates
Study Start (Estimated)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- FW-ZEL-005
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.