Noninvasive Assessment of Intracranial Pressure Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients (COSMO)
Noninvasive Intracranial Pressure Assessment Using Otoacoustic Emissions in Healthy Subjects and Glaucoma Patients
The COSMO study aims to investigate whether a noninvasive test based on otoacoustic emissions, which are sounds produced by the inner ear, can provide useful information about changes in intracranial pressure in people with glaucoma and healthy individuals.
Glaucoma is an eye disease that can damage the optic nerve and cause vision loss. Researchers believe that the relationship between pressure inside the eye and pressure inside the skull may play a role in glaucoma.
This study will compare measurements of distortion product otoacoustic emissions (DPOAEs) between patients with glaucoma and healthy participants. Researchers will assess how reproducible these measurements are and how they change with different body positions and changes in intraocular pressure.
Participants will undergo eye examinations and noninvasive ear measurements while assuming different body positions.
The results may help researchers better understand the relationship between intracranial pressure, intraocular pressure, and glaucoma, and evaluate the potential usefulness of otoacoustic emissions as a noninvasive assessment method.
Study Overview
Status
Status
Conditions
Conditions
Intervention / Treatment
Intervention / Treatment
Detailed Description
COSMO is a single-center, prospective, interventional clinical study with a medical device designed to investigate the reproducibility of distortion product otoacoustic emission (DPOAE) phase measurements in patients with glaucoma and healthy subjects.
The study is based on the hypothesis that changes in intracranial pressure may influence otoacoustic emissions and that the relationship between intracranial pressure and intraocular pressure (IOP) may be relevant to glaucoma.
**Primary Objective**
To assess the reproducibility of DPOAE phase measurements and compare their repeatability between patients with glaucoma and healthy subjects.
**Secondary Objectives**
- To compare changes in DPOAE phase and intraocular pressure (ΔIOP) between glaucoma patients and healthy subjects.
- To investigate the relationship between DPOAE phase changes and intraocular pressure changes across different body positions.
- To explore the influence of central corneal thickness and corneal hysteresis on these relationships.
**Study Procedures**
Following written informed consent, participants will undergo a screening assessment to confirm eligibility.
Screening examinations will include:
- Best-corrected visual acuity assessment.
- Anterior segment biomicroscopy.
- Visual field testing in glaucoma patients.
- Optical coherence tomography (OCT) of the optic nerve head and macula.
- Intraocular pressure measurement.
- Fundus examination.
- Otoscopy to assess ear canal patency.
Eligible participants will undergo additional measurements of central corneal thickness, corneal hysteresis, and optic nerve ultrasonography.
Intraocular pressure and DPOAE measurements will be assessed in different body positions, including sitting, supine, semi-reclined, and prone positions. The order of body positions will be randomly assigned using a computer-generated sequence.
Participants will maintain each assigned position for at least 30 minutes before the measurements.
DPOAEs will be recorded using a portable measurement system with a probe placed in the ear canal. Measurements will be performed over a frequency range of 500 to 4000 Hz.
In the sitting position, DPOAE measurements will be repeated after removing and reinserting the ear probe to evaluate test-retest repeatability.
**Outcome Assessment**
The primary endpoint is the repeatability of DPOAE phase measurements in glaucoma patients and healthy subjects.
Secondary assessments will investigate differences and correlations between DPOAE phase changes and intraocular pressure changes across different body positions, including their relationships with central corneal thickness and corneal hysteresis.
All study assessments will be completed during a single study visit consisting of screening and testing procedures. No additional study-specific follow-up visits are planned.
The findings may contribute to the development of noninvasive methods for investigating pressure-related mechanisms in glaucoma.
Study Type
Study Type
Enrollment (Estimated)
Enrollment
Phase
Phase
- Not Applicable
Contacts and Locations
Study Contact
Study Contact
- Name: Francesco Oddone, MD
- Phone Number: +390684009442
- Email: francesco.oddone@fondazionebietti.it
Study Contact Backup
- Name: Sara Giammaria, MD
- Email: sara.giammaria@fondazionebietti.it
Study Locations
-
-
-
Roma, Italy, 00184
- Recruiting
- IRCCS Fondazione G.B.Bietti
-
Contact:
- Sara Giammaria
- Phone Number: +390684009442
- Email: sara.giammaria@fondazionebietti.it
-
-
Participation Criteria
Eligibility Criteria
Eligibility Criteria
Ages Eligible for Study
Accepts Healthy Volunteers
Genders Eligible for Study
Description
**Inclusion Criteria:**
General inclusion criteria (all participants):
- Age between 50 and 70 years.
- Central corneal thickness between 500 and 600 µm.
- Patent ear canal at otoscopy.
- Written informed consent freely provided before the start of any study procedures.
- Ability to understand and willingness to follow study instructions and likely to complete all required study visits and procedures.
Additional inclusion criteria for healthy subjects:
- No eye disease.
- No family history of glaucoma.
Additional inclusion criteria for glaucoma patients:
- Clinical diagnosis of primary open-angle glaucoma, normal-tension glaucoma, pseudoexfoliative glaucoma, or pigmentary glaucoma.
- Reproducible visual field defect on the Humphrey Field Analyzer (HFA) 24-2 test compatible with glaucoma, defined by the presence of a cluster of three or more non-continuous points in the pattern deviation plot with a probability of occurrence in the normal population of less than 5%, including at least one point with p < 1%, a pattern standard deviation with p < 5%, or a Glaucoma Hemifield Test result outside normal limits.
- Optic nerve head (ONH) abnormalities compatible with glaucoma, including generalized or focal enlargement of the optic cup, thinning of the neuroretinal rim, cup-to-disc ratio asymmetry greater than 0.2 between eyes, or retinal nerve fiber layer loss.
**Exclusion Criteria:**
General exclusion criteria (all participants):
- History of inner or middle ear disease.
- History of cerebral diseases that may increase intracranial pressure (ICP), including neoplastic, ischemic, toxic, or infectious causes of cerebral edema, hydrocephalus, obstruction of major venous sinuses, vascular malformations, or idiopathic intracranial hypertension.
- Systemic treatment with medications known to affect ICP, including corticosteroids, nitroprusside, nitroglycerin, hydralazine, nicardipine, topiramate, and loop diuretics (e.g., furosemide).
- Non-recordable distortion product otoacoustic emissions (DPOAEs).
- Uncontrolled blood pressure, with or without systemic treatment.
- Retinal or optic nerve head diseases other than glaucoma, as assessed by optical coherence tomography (OCT) scans of the macula, optic nerve head, and retinal nerve fiber layer (RNFL).
- Phacoemulsification or glaucoma filtering surgery within the previous 6 months.
Additional exclusion criterion for healthy subjects:
- Intraocular pressure (IOP) greater than 21 mmHg.
Additional exclusion criterion for glaucoma patients:
- Oral acetazolamide treatment as part of the therapeutic regimen, due to its potential effect on intracranial pressure.
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Non-Randomized
- Interventional Model: Parallel Assignment
- Masking: None (Open Label)
Number of Arms
Arms and Interventions
Participant Group / ArmParticipant Group / Arm |
Intervention / TreatmentIntervention / Treatment |
|---|---|
|
Experimental: Glaucoma Patients
Patients diagnosed with glaucoma who will undergo noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. DPOAE phase measurements will be used to evaluate test-retest repeatability and investigate the relationship between otoacoustic emission changes and intraocular pressure variations. |
Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark). DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence. Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz. In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability. |
|
Experimental: Healthy Subjects
Healthy participants without glaucoma who will undergo the same noninvasive distortion product otoacoustic emission (DPOAE) measurements and intraocular pressure assessments in different body positions. Measurements will be used to evaluate test-retest repeatability and provide comparative data for the glaucoma group. |
Noninvasive measurement of distortion product otoacoustic emissions (DPOAEs) using the Titan System with IMP440 Impedance System version 3.7 (Interacoustics A/S, Denmark). DPOAE phase measurements will be performed in different body positions (sitting at 90°, semi-reclined at 135°, supine at 180°, and prone at 0°), with the order randomly assigned using a computer-generated sequence. Participants will maintain each position for at least 30 minutes before DPOAE and intraocular pressure measurements. DPOAEs will be recorded over a frequency range of 500 to 4000 Hz. In the sitting position, DPOAE measurements will be repeated three times to assess test-retest repeatability. |
What is the study measuring?
Primary Outcome Measures
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Repeatability of Distortion Product Otoacoustic Emission (DPOAE) Phase Measurements
Time Frame: During the single study visit (Day 1)
|
Assessment of the test-retest repeatability of distortion product otoacoustic emission (DPOAE) phase measurements in glaucoma patients and healthy subjects. DPOAE phase will be measured repeatedly in the sitting position (90°), with removal and reinsertion of the ear probe between measurements. Repeatability will be quantified as the standard deviation of differences between repeated measurements, expressed in degrees of phase. |
During the single study visit (Day 1)
|
Secondary Outcome Measures
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Differences in DPOAE Phase Changes and Intraocular Pressure Changes Between Study Groups
Time Frame: During the single study visit (Day 1)
|
Comparison of distortion product otoacoustic emission (DPOAE) phase changes, expressed in degrees and averaged over three octave bands (0.5-1, 1-2, and 2-4 kHz), and mean changes in intraocular pressure (ΔIOP), expressed in mmHg, between glaucoma patients and healthy subjects across different body positions (90°, 135°, 180°, and 0°). |
During the single study visit (Day 1)
|
|
Association Between DPOAE Phase Changes, Intraocular Pressure Changes, and Corneal Parameters
Time Frame: During the single study visit (Day 1)
|
Assessment of the relationship between distortion product otoacoustic emission (DPOAE) phase changes (degrees) and intraocular pressure changes (ΔIOP, mmHg) across different body positions, considering central corneal thickness (µm) and corneal hysteresis (mmHg). Associations will be evaluated using Pearson or Spearman correlation coefficients and mixed-effects models. |
During the single study visit (Day 1)
|
Collaborators and Investigators
Sponsor
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Study Start
Primary Completion (Estimated)
Primary Completion
Study Completion (Estimated)
Study Completion
Study Registration Dates
First Submitted
First Submitted
First Submitted That Met QC Criteria
First Submitted That Met QC Criteria
First Posted (Actual)
First Posted
Study Record Updates
Last Update Posted (Actual)
Last Update Posted
Last Update Submitted That Met QC Criteria
Last Update Submitted That Met QC Criteria
Last Verified
Last Verified
More Information
Terms related to this study
Keywords
Additional Relevant MeSH Terms
Other Study ID Numbers
Other Study ID Numbers
- GLC 04-23
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.