High Flow Ventilation With Volume Guarantee

October 7, 2015 updated by: Oslo University Hospital

Pilot Study: High Flow Ventilation With Volume Guarantee

The trial is a pilot study performed in the NICU's at Oslo University Hospital and Haukeland University Hospital preparing a multi-center randomized, controlled unblinded cross-over study, comparing high frequency ventilation (HFV) with and without volume guarantee (VG).

Study Overview

Status

Unknown

Intervention / Treatment

Detailed Description

HFV is a way to deliver mechanical breathing support to patients with respiratory failure applied in Neonatal Intensive Care Units (NICU's). In some NICU's, this mode of ventilation is applied when conventional ventilation fails, whereas in other units HFV is used as the primary ventilation mode.

HFV is a ventilator mode where high frequency pressure changes, typically 6-12 per second (6 - 12 Hertz (Hz)), is used to exchange air between the lungs (alveoli) and the ventilator tubing.

Concerns have been raised regarding fluctuating PCO2 values in babies receiving HFV. It is believed that stable normocapnia (normal PCO2 values) as opposed to hyper- and hypocapnia is associated to better short and long-term outcomes.

In conventional ventilator modes, CO2 diffusion is a function of the product from volume per breath (Vt) and the frequency (f) of breathing (Vt*f = minute volume (MV)). In HFV the CO2 diffusion is a function of a product from the small tidal volumes generated (Vthf) squared, and the oscillation frequency (Hz) delivered by the ventilator (vthf2 * F=DCO2). The small tidal volumes are being adjusted by altering the pressure range (amplitude) and the frequency by which pressure changes is generated. One challenge in using HFV has been unwanted fluctuations in PCO2 values, which has been shown to be associated with clinical important complications, in particular cerebral hemorrhages. In order to avoid substantial fluctuation in PCO2 a meticulous adjustment of the amplitude is required.

Modern neonatal ventilators now offer the ability to automatically adjust the amplitude of the high frequency breaths to obtain a stable high frequency tidal volume. The ventilator measures the Vthf and increase or decrease the power of each breath to obtain the set Vthf. This mode is called high frequency ventilation with volume guarantee (HFV+VG).

Automatically adjustment of the amplitude is a novel option in high frequency ventlators and has not been studied in randomized trials.

This study will investigate compare HFV with and without VG. Patients treated with HFV will be randomized to conventional HFV or HFV+VG. After 24 hours the mode will be changed to HFV+VG for those starting on HFV and to HFV for those starting on HFV+VG for 24 hours. After the trial period of 24 x 2 hours - the HFV mode will be at the clinician's preference.

To compare the efficiency of both modes of HFV, measured PCO2 values, oxygen need and variables from the ventilator will be sampled. These variables describe the effort from the ventilator (frequency, amplitude) as well as variables associated with gas exchange in the lungs (Vthf, DCO2).

Study Type

Interventional

Enrollment (Anticipated)

15

Phase

  • Not Applicable

Contacts and Locations

This section provides the contact details for those conducting the study, and information on where this study is being conducted.

Participation Criteria

Researchers look for people who fit a certain description, called eligibility criteria. Some examples of these criteria are a person's general health condition or prior treatments.

Eligibility Criteria

Ages Eligible for Study

No older than 3 months (Child)

Accepts Healthy Volunteers

No

Genders Eligible for Study

All

Description

Inclusion Criteria:

  • all neonates in need of high frequency ventilator

Exclusion Criteria:

  • neonates expected to need high frequency ventilator less than 48 hours because of planned surgery etc

Study Plan

This section provides details of the study plan, including how the study is designed and what the study is measuring.

How is the study designed?

Design Details

  • Primary Purpose: Treatment
  • Allocation: Randomized
  • Interventional Model: Crossover Assignment
  • Masking: None (Open Label)

Arms and Interventions

Participant Group / Arm
Intervention / Treatment
Experimental: HFV+vg
volume guarantee given
High frequency ventilation with and without volume guarantuee
Experimental: HFV-VG
Volume guarantee not given
High frequency ventilation with and without volume guarantuee

What is the study measuring?

Primary Outcome Measures

Outcome Measure
Measure Description
Time Frame
stability of High Frequency Tidal volumes
Time Frame: during study, ie. 48 hours.
HFVVt are measured by ventilator.
during study, ie. 48 hours.
Stability of CO2 measurements
Time Frame: during study, ie. 48 hours.
Measured CO2 values will be measured as usual
during study, ie. 48 hours.
frequency of needed manual adjustments on the ventilator
Time Frame: during study, ie 48 hours
Adjustments made on ventilator will be automatically sampled by the ventilator
during study, ie 48 hours

Collaborators and Investigators

This is where you will find people and organizations involved with this study.

Investigators

  • Principal Investigator: Bjorn e Ogland, md dr philos, Oslo University Hospital

Study record dates

These dates track the progress of study record and summary results submissions to ClinicalTrials.gov. Study records and reported results are reviewed by the National Library of Medicine (NLM) to make sure they meet specific quality control standards before being posted on the public website.

Study Major Dates

Study Start

November 1, 2015

Primary Completion (Anticipated)

July 1, 2016

Study Completion (Anticipated)

July 1, 2016

Study Registration Dates

First Submitted

September 28, 2015

First Submitted That Met QC Criteria

October 7, 2015

First Posted (Estimate)

October 8, 2015

Study Record Updates

Last Update Posted (Estimate)

October 8, 2015

Last Update Submitted That Met QC Criteria

October 7, 2015

Last Verified

September 1, 2015

More Information

This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.