Combining Artificial Intelligence With Balloon Mucosal Exposure Device for Polyp Detection in Screening Individuals (COMBAT)
Impact on Polyp Detection of a Computer Aided Detection System (CADEYE) Combined With a Balloon Mucosal Exposure Device (G-EYE 760R) in Individuals Participating in a Organized Colorectal Cancer Screening Program
The present trial is aimed at evaluating whether in individuals scheduled for colonoscopy in the framework of a structured FIT (Fecal Immunochemical stool test)-based colorectal cancer screening program, the combination of an AI (artificial intelligence) system (CADEYE) with a mucosal exposure device (G-EYE 760R endoscope) increases the identification of subjects at high risk to develop colorectal cancer (according to recent ESGE-European Society of Gastrointestinal Endoscopy guidelines subjects are labelled as "high-risk" if harboring at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia) when compared to colonoscopy performed with the support of AI only.
Individuals fulfilling inclusion criteria are randomized (1:1) to two different arms (Control arm and Interventional arm, see below). Randomization is based on a computer-generated randomized block sequence, stratified according to age (50-61 vs. 62-74) and gender (male vs. female); size of the blocks (10 individuals) is not communicated to the investigator. Allocation is concealed and kept in a sealed envelope, which is opened just before starting colonoscopy.
Individuals randomized in the Intervention arm receive colonoscopy examination with G-EYE 760R colonoscopes; once the cecum is reached the balloon is inflated, and the endoscope is withdrawn with the inflated balloon; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination.
Individuals randomized in the Control arm (CADEYE only) receive colonoscopy with G-EYE 760R colonoscope but the balloon remains deflated for the entire procedure; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination.
The main outcome measure is the rate of "high risk" individuals across the two study arms.
Study Overview
Detailed Description
The Italian Colorectal Cancer (CRC) screening program invites the resident population aged 50-74 years for Fecal Immunochemical Test (FIT) every 2 years. Subjects who test positive are referred for colonoscopy. Colonoscopy and polypectomy prevent incident cases of colorectal cancer by their detection at an early and curable stage, and by identification and removal of colorectal precancerous lesions (i.e. adenomas). Taking into account the number and the histological features of polyps identified, colonoscopy also allows to stratify individuals according to the risk of developing colorectal cancer over time (low-risk vs. high-risk subjects), thus allowing to plan a balanced risk-based follow-up schedule: high-risk individuals are scheduled for a surveillance colonoscopy in 3 years, whereas low-risk individuals are scheduled for a further FIT test in five years or for a new colonoscopy in 10 years. However, colonoscopy is far from being a flawless tool. Studies that have measured the incidence of colorectal cancer diagnosed in subjects who have recently undergone colonoscopy with negative results (the so-called interval cancers) have shown that a significant portion of interval cancers is related to pre-neoplastic, or frankly neoplastic colonic lesions, missed during the endoscopic procedure.
In the last few years, it has been shown that in patients undergoing colonoscopy for mixed indications AI-based systems can effectively support the endoscopist by decreasing the adenoma miss rate and by increasing the identification of colonic polyps, thus potentially lowering the rate of interval cancer and increasing the rate of individuals scheduled for a short follow-up. A recent study demonstrated that AI-assisted colonoscopy is effective also in the framework of a FIT-based organized CRC screening program resulting in an absolute difference of 8.3% and 0.23 for adenoma detection rate (ADR) and for adenomas per colonoscopy (APC), when compared to standard colonoscopy performed without the assistance of AI. Nevertheless, tandem studies have shown that despite the use of AI systems the miss rate of colonic adenomas is still about 15-20%. In fact, AI systems only allow to highlight polyps that are framed by the endoscopist within the screen. Therefore, the use of computerized AI-based system cannot disregard an accurate retraction technique, focused on exploring in an extensive and effective way the space between the folds. Several tools, mostly consisting of distal attachments or plastic caps, aimed at facilitating the evaluation of the space between the folds favoring their smoothing during the endoscope withdrawal, have been developed to maximize mucosal exposure. Among them, the G-EYE system includes a balloon integrated at the distal tip of a standard colonoscope, which flattens haustral folds, centralizes the colonoscope's optics, and reduces bowel slippage during endoscope withdrawal. Initial studies showed that G-EYE balloon system, when compared with standard colonoscopy, increases not only adenoma detection rate but also the detection of advanced, flat, and sessile serrated adenomas/polyps. Recently, a new user friendly G-EYE balloon system (G-EYE 760R endoscope) has been marketed: it consists of a standard last-generation colonoscope with a permanently integrated balloon, placed at the bending section of the endoscope, which can be gradually insufflated on-demand by the endoscopist through a pedal control. It can be hypothesized that the combination of AI systems with mucosal exposure devices might further decrease the polyp miss rate, by maximizing the detection of adenomas. Moreover, initial studies based on such a strategy, combining AI with mucosal exposure devices, yielded encouraging results. However, the combination of CADEYE with G-EYE 760R endoscopes has not been evaluated so far.
The present prospective randomized controlled trial is aimed at evaluating whether in individuals scheduled for colonoscopy in the framework of a structured FIT-based colorectal cancer screening program, the combination of an AI system (CADEYE) with a mucosal exposure device (G-EYE 760R endoscope) increases the identification of subjects at high risk to develop colorectal cancer, when compared to colonoscopy performed with the support of AI only. In addition, it will be also evaluated whether the use of an AI system combined with a mucosal exposure device, increases:
- the adenoma detection rate (i.e. the rate of individuals with at least one histologically confirmed adenoma)
- the number of adenomas per colonoscopy (i.e. the number of adenomas detected divided by the number of all colonoscopies performed)
- the serrated lesions with neoplastic potential (sessile serrated lesions-SSA; traditional serrated adenomas - TSA) detection rate.
- the detection rate of right colon adenomas
- the detection rate on non-polypoid colonic lesions. Individuals fulfilling the inclusion criteria are randomized (1:1) in two arms (see below). Randomization is based on a computer-generated randomized blocks sequence, stratified according to age (50-61 vs. 62-74) and gender (male vs. female); size of the blocks (10 individuals) is not communicated to the investigator. Allocation is concealed and kept in a sealed envelope, which is opened just before starting the procedure.
Randomization groups:
- Group A (CADEYE only): all subjects receive colonoscopy with G-EYE 760R colonoscope but the balloon remains deflated for the entire procedure; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination.
- Group B (CADEYE+G-EYE 760R): all individuals receive colonoscopy examination with G-EYE 760R colonoscopes; once the cecum is reached the balloon is inflated, and the endoscope is withdrawn with the inflated balloon; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination.
For the present study a clinical outcome measure, such as the rate of "high risk" individuals across the two study arms, is calculated and compared. According to recent European Society of Gastrointestinal Endoscopy (ESGE) guidelines subjects are labelled as "high-risk" if harboring at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia.
All endoscopic procedures are performed using the ELUXEOTM 7000 endoscopy platform (including videoprocessor ELUXEO TM VP-7000 and light source ELUXEO TM BL-7000; Fujifilm Co., Tokyo, Japan), high-definition 26''monitors (Barco NV, Kortijk, Belgium) and G-EYE 760R endoscopes (Fujifilm Co., Tokyo, Japan).
Bowel preparation is a split regimen of low-volume solution, according to local protocol. Quality of bowel cleansing is recorded by using the Boston Bowel Preparation Scale. Colonoscopies are performed under conscious sedation with carbon dioxide insufflation. Intubation time, overall withdrawal time, intervention time and inspection time during withdrawal are measured using a stopwatch. An inspection time of at least 6 minutes (2 minutes in each colonic segment, namely right, transverse and left colon) is mandatory in both study arms. The mucosa is carefully inspected, and all polyps are classified according to their location, size, and morphology (according to Paris classification). The pathologist's measure, when available, is considered the reference standard; the endoscopist's measure estimation is used in the remaining cases (i.e., piecemeal resection). Polyp location is defined as "proximal" if proximal to the splenic flexure). All identified polyps are removed (biopsy for non-resectable lesions), irrespective of size, color or subjective interpretation, with the possible exception of very small (1-5 mm) hyperplastic-appearing polyps located in the rectum and-according to the judgment of the endoscopists-not clinically significant.
All participating endoscopists have credentials for participating in the organized FIT-based screening program (more than 300 colonoscopies/year; cecal intubation rate >95%, adenoma detection rate>25%). All endoscopist are familiar with CADEYE features and use this system on a regular basis. All participating endoscopists receive a formal training (a 20' lecture focused on the use of the G-EYE 760R endoscope). All of them performed at least 10 colonoscopies with the G-EYE 760R endoscope, to become acquainted with the system, before entering the study.
All resected or biopsy specimens are fixed in 10% buffered formalin solution sent to pathology in separate jars. They are processed and stained for histopathology using standard methods and evaluated by expert pathologists (one in each center), with credentials to participate in the FIT-based organized screening program; pathologists are blinded to the assigned examination mode. All lesions are classified according to Vienna classification. An advanced adenoma is defined as an adenoma ≥10 mm and/or with villous component >20%, and/or high-grade dysplasia.
Study Type
Enrollment (Actual)
Phase
- Not Applicable
Contacts and Locations
Study Locations
-
-
-
Como, Italy, 22100
- Gastroenterology Unit, Valduce Hospital
-
-
Participation Criteria
Eligibility Criteria
Ages Eligible for Study
- Adult
- Older Adult
Accepts Healthy Volunteers
Description
Inclusion Criteria:
- Consecutive adult (50-74 yrs.) outpatients undergoing colonoscopy in the framework of the FIT-based screening program.
Exclusion Criteria:
- Individuals with CRC (Colorectal Cancer) history or hereditary polyposis syndromes or hereditary non-polyposis colorectal cancer
- Individuals with inadequate bowel preparation (defined as Boston Bowel Preparation score <2 in at least one colonic segment)
- Individuals in which cecal intubation was not achieved or scheduled for partial examinations
- Individuals with gastrointestinal symptoms
- Individuals in whom polyps could not be resected due to ongoing anticoagulation preventing resection and pathological assessment
Study Plan
How is the study designed?
Design Details
- Primary Purpose: Diagnostic
- Allocation: Randomized
- Interventional Model: Parallel Assignment
- Masking: Single
Arms and Interventions
Participant Group / Arm |
Intervention / Treatment |
|---|---|
|
Experimental: GI-EYE endoscope with inflated ballon (Interventional arm)
all individuals receive colonoscopy examination with G-EYE 760R colonoscopes; once the cecum is reached the balloon is inflated, and the endoscope is withdrawn with the inflated balloon; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination.
|
The G-EYE 760 endoscope consists of a standard last-generation colonoscope with a permanently integrated balloon, placed at the bending section of the endoscope, which can be gradually insufflated on-demand by the endoscopist through a pedal control.
During the endoscope withdrawal the balloon flattens haustral folds, centralizes the colonoscope's optics and reduces bowel slippage, thus facilitating mucous inspection and polyp detection.
|
|
No Intervention: G-EYE endoscope with deflated balloon (Control arm)
all subjects receive colonoscopy with G-EYE 760R colonoscope but the balloon remains deflated for the entire procedure; the colonoscopy is performed with the support of the CADEYE system for polyp detection in both insertion and withdrawal phase; all polyps identified are removed and sent for histopathology examination
|
What is the study measuring?
Primary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Rate of "high risk" patients
Time Frame: through study completion, an average of 6 months
|
Rate of individuals labelled as "high risk" to develop colon cancer according to recent ESGE guidelines (i.e.
subjects harboring at least 1 adenoma ≥ 10 mm or with high grade dysplasia, or ≥ 5 adenomas, or any serrated polyp ≥ 10 mm or with dysplasia).
|
through study completion, an average of 6 months
|
Secondary Outcome Measures
Outcome Measure |
Measure Description |
Time Frame |
|---|---|---|
|
Adenoma detection rate
Time Frame: through study completion, an average of 6 months
|
Rate of individuals with at least one adenoma detected
|
through study completion, an average of 6 months
|
|
Adenomas per colonoscopy
Time Frame: through study completion, an average of 6 months
|
the number of adenomas detected divided by the number of all colonoscopies performed
|
through study completion, an average of 6 months
|
|
Serrated lesion detection rate
Time Frame: through study completion, an average of 6 months
|
Rate of individuals with at least one serrated lesion detected
|
through study completion, an average of 6 months
|
|
Right sided adenoma detection rate
Time Frame: through study completion, an average of 6 months
|
Rate of individuals with at least one right sided adenoma detected
|
through study completion, an average of 6 months
|
Collaborators and Investigators
Sponsor
Study record dates
Study Major Dates
Study Start (Actual)
Primary Completion (Actual)
Study Completion (Actual)
Study Registration Dates
First Submitted
First Submitted That Met QC Criteria
First Posted (Actual)
Study Record Updates
Last Update Posted (Actual)
Last Update Submitted That Met QC Criteria
Last Verified
More Information
Terms related to this study
Additional Relevant MeSH Terms
Other Study ID Numbers
- Valduce Hospital
Plan for Individual participant data (IPD)
Plan to Share Individual Participant Data (IPD)?
Drug and device information, study documents
Studies a U.S. FDA-regulated drug product
Studies a U.S. FDA-regulated device product
This information was retrieved directly from the website clinicaltrials.gov without any changes. If you have any requests to change, remove or update your study details, please contact register@clinicaltrials.gov. As soon as a change is implemented on clinicaltrials.gov, this will be updated automatically on our website as well.
Clinical Trials on Polyp of Colon
-
University College, LondonRecruitingPolyps | Colon Polyp | Adenoma Colon | Colorectal Polyp | Polyps of ColonUnited Kingdom
-
University of ManitobaCompletedPolyps | Colonic Polyp | Polyp of Colon | Colo-rectal Cancer | Colon Polyp | Rectal Polyp | Polyp RectalCanada
-
Asian Institute of Gastroenterology, IndiaRecruitingPolyps | Polyps of Colon | Polyp IntestineIndia
-
Centre Hospitalier Departemental VendeeTerminated
-
Lumendi, LLCUnknown
-
Hôpital Edouard HerriotCompleted
-
Robert Bosch Gesellschaft für Medizinische Forschung...Ovesco Endoscopy AG; Tuebingen Scientific Medical GmbHRecruitingAdenoma Colon | Adenoma Colon PolypGermany
-
Lumendi, LLCUnknown
-
Baylor College of MedicineTerminatedAdenomatous Polyp of ColonUnited States
-
Queen's UniversityHotel Dieu Hospital (Gastrointestinal Diseases Research Unit)CompletedQuality of Bowel Preparation for the Colon Capsule | Colon Capsule Completion Rates | Colon Capsule Polyp DetectionCanada
Clinical Trials on G-EYE 760 R endoscope
-
National Cancer Institute (NCI)CompletedGastric Cancer | Gastric NeoplasmsUnited States
-
HutchmedActive, not recruitingRelapsed/Refractory Diffuse Large B-Cell LymphomaChina
-
Institut Paoli-CalmettesCompletedColorectal AdenomaFrance
-
Smart Medical Systems Ltd.FujifilmRecruitingColorectal Cancer | AdenomaGermany
-
Dr. Horst Schmidt Klinik GmbHCompletedAdenoma | Colo-rectal CancerGermany
-
Smart Medical Systems Ltd.CompletedColorectal Cancer | Adenoma | PolypIsrael
-
Smart Medical Systems Ltd.CompletedColorectal Cancer | Adenoma | PolypsUnited States, Netherlands, Israel, United Kingdom, India, Germany, Denmark, Italy
-
Smart Medical Systems Ltd.UnknownColorectal Cancer | Adenoma | PolypsIsrael
-
Smart Medical Systems Ltd.CompletedColorectal Cancer | AdenomaGermany
-
Smart Medical Systems Ltd.CompletedColorectal Cancer | Adenoma | PolypIsrael, Germany