Užitečnost vlastností kortikální kostní tkáně při hodnocení rizika zlomenin
The objective of this study is to determine whether a new minimally invasive method for in vivo measurement of cortical bone tissue properties can identify those who are at risk for fragility fractures of the hip and radius. The investigators hypothesis is that women with fragility fractures of the hip and radius have altered cortical bone tissue properties compared to non-fracture controls independent of standard clinical tests, such as bone mineral density (BMD) by dual-energy x-ray absorptiometry (DXA).
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
The objective of this study is to determine whether a new minimally invasive method for in vivo measurement of cortical bone tissue properties can identify those who are at risk for fragility fractures of the hip and radius. The investigators hypothesis is that women with fragility fractures of the hip and radius have altered cortical bone tissue properties compared to non-fracture controls independent of standard clinical tests, such as BMD. To test these hypotheses, The investigators propose two aims:
Aim 1: Compare cortical bone tissue properties as assessed in vivo by reference point indentation in women with hip fractures and non-fracture controls.
The investigators will compare cortical bone tissue material properties, as assessed by novel in vivo indentation at the mid-tibia in postmenopausal women with recent hip fractures (n) and age-similar controls without fractures (n=). In addition to in vivo indentation measurements, The investigators will assess hip and spine BMD by DXA; as well as other factors that may influence risk of fractures (e.g, vit D status, medication use and physical activity). Hypotheses: Postmenopausal women with hip fractures will have worse bone tissue material properties compared to non-fracture controls even after adjustment for BMD and other potential confounders.
Aim 2: Compare cortical bone tissue properties as assessed in vivo by reference point indentation in women with distal radius fractures to non-fracture controls.
The investigators will compare cortical bone tissue material properties, as assessed by novel in vivo indentation at the mid-tibia in postmenopausal women with recent distal radius fractures (n) and age-similar controls without fractures (n=). In addition to in vivo indentation measurements, The investigators will assess hip and spine BMD by DXA; as well as other factors that may influence risk of fractures (e.g, vit D status, medication use and physical activity). Hypotheses: Postmenopausal women with distal radius fractures will have worse bone tissue material properties compared to non-fracture controls even after adjustment for BMD and other potential confounders.
Successful completion of this project will address the need to better assess bone mechanical properties at the tissue level in order to accurately predict fracture risk. The study will provide novel information about possible clinical utility of minimally invasive, in vivo bone indentation measurements to measure bone strength and its relationship to fracture risk.
Aim 3: An amendment to the protocol expanded the study population to now include males >50 years who present with distal radius fractures and those who present for a reason other than fracture (non-fracture controls). Hypotheses: Men >50 years with distal radius fractures will have worse bone tissue material properties compared to non-fracture controls even after adjustment for BMD and other potential confounders.
Typ studie
Typ studie
Zápis (Odhadovaný)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
Massachusetts
-
Boston, Massachusetts, Spojené státy, 02215
- Beth Israel Deaconess Medical Center
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
Přijímá zdravé dobrovolníky
Pohlaví způsobilá ke studiu
Popis
Inclusion Criteria:
- Women with hip and wrist fractures within 2 weeks of presentation
- Non-fracture controls
Exclusion Criteria:
- Unable to undergo BMD by DXA or high-resolution peripheral quantitative computed tomography (HR-pQCT)
- History of skeletal metastasis, primary hyperparathyroidism, Paget's disease, multiple myeloma
- Treatment with bisphosphonate, estrogen (within previous 3 years), teriparatide therapy, calcitonin, selective estrogen receptor modulator (SERMs,within previous 3 years)
- Use of glucocorticoids continuously for more than 3 months, use of anticonvulsants
- Prior fracture in adulthood (>age 18) for healthy controls
Amendment to protocol added Arm 2, to include males >50 years with otherwise similar eligibility criteria.
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Prevence
- Přidělení: Nerandomizované
- Intervenční model: Přiřazení jedné skupiny
- Maskování: Žádné (otevřený štítek)
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Experimentální: Post-menopausal women
We will use the handheld Osteoprobe device to measure cortical bone reference point indentation properties. |
The "Osteoprobe": Since these first reports of indentation measurements in humans in vivo, a more 'user-friendly' device, the Osteoprobe® has been developed by Active Life Scientific (Santa Barbara, CA) (10). The Osteoprobe®, which we will use in the current study, is smaller than the previous reference point indentation (RPI) instrument and is designed to be used in a hand-held fashion to allow for rapid measurements. The new instrument does not require a reference probe, because the inertia of the instrument keeps it adequately fixed in space during the short time of the indentation impact (~0.25 milliseconds). The main parameter measured is the distance that the probe further indents into the bone from the reference point. Key components of the Osteoprobe® include an impact generation mechanism, a displacement transducer, and a probe made of hardened stainless steel with a 90 degree conical tip, with a tip diameter of ~375 µm.
Ostatní jména:
|
|
Experimentální: Males over 50 years
We will recruit males to this second study arm, to use the handheld Osteoprobe device to measure cortical bone reference point indentation properties. |
The "Osteoprobe": Since these first reports of indentation measurements in humans in vivo, a more 'user-friendly' device, the Osteoprobe® has been developed by Active Life Scientific (Santa Barbara, CA) (10). The Osteoprobe®, which we will use in the current study, is smaller than the previous reference point indentation (RPI) instrument and is designed to be used in a hand-held fashion to allow for rapid measurements. The new instrument does not require a reference probe, because the inertia of the instrument keeps it adequately fixed in space during the short time of the indentation impact (~0.25 milliseconds). The main parameter measured is the distance that the probe further indents into the bone from the reference point. Key components of the Osteoprobe® include an impact generation mechanism, a displacement transducer, and a probe made of hardened stainless steel with a 90 degree conical tip, with a tip diameter of ~375 µm.
Ostatní jména:
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
Cortical bone tissue properties by reference point indentation
Časové okno: Day 1
|
Osteoprobe measurement |
Day 1
|
|
Bone mineral density (BMD) by dual-energy x-ray absorptiometry (DXA)
Časové okno: Day 1
|
DXA at the hip and spine |
Day 1
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Spolupracovníci
Spolupracovníci
Vyšetřovatelé
Vyšetřovatelé
- Vrchní vyšetřovatel: Tamara Rozental, M.D., Beth Israel Deaconess Medical Center
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Odhadovaný)
Primární dokončení
Dokončení studie (Odhadovaný)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Další relevantní podmínky MeSH
Další identifikační čísla studie
Další identifikační čísla studie
- 2014P000226
Plán pro data jednotlivých účastníků (IPD)
Plánujete sdílet data jednotlivých účastníků (IPD)?
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
produkt vyrobený a vyvážený z USA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .