Evaluation of Composite Veneers Fabricated by 3D Printing and Milling Technologies
Evaluation of Composite Veneers Fabricated by 3D Printing and Milling Technologies (Randomized Controlled Clinical Trial & In-Vitro Study)
Přehled studie
Postavení
Postavení
Podmínky
Podmínky
Intervence / Léčba
Intervence / Léčba
Detailní popis
Typ studie
Typ studie
Zápis (Aktuální)
Zápis
Fáze
Fáze
- Nelze použít
Kontakty a umístění
Studijní místa
-
-
-
Alexandria, Egypt
- Faculty of dentistry, Alexandria university
-
-
Kritéria účasti
Kritéria způsobilosti
Kritéria způsobilosti
Věk způsobilý ke studiu
- Dospělý
Přijímá zdravé dobrovolníky
Popis
Inclusion Criteria:
- Healthy adult patients aged 18 to 45 years.
- Patients requiring veneer restorations due to discoloration, misalignment, tooth malformation or having irregular tooth shape that can be treated without full coverage.
- Patients meeting the criteria for Class I or Class II veneers according to the LeSage veneer classification system.
- Patients requiring veneers restorations on their bilateral maxillary anterior teeth.
- The selected teeth should be vital with absence of clinical signs and symptoms of periapical pathology.
- Patients having a normal occlusal relationship between upper and lower teeth (class I Angle classification).
- Patients capable of tolerating rubber dam applications.
- Patients willing to attend regular follow-up appointments.
Exclusion Criteria:
- Bad oral hygiene (Oral Hygiene Index Simplified >3).
- Non-vital teeth or endodontically treated teeth.
- Severe periodontal disease.
- Patients with para-functional habits (e.g., bruxism, attrition, wear facets).
- Dentin exposure more than 20% of the prepared surface for veneer.
- Prescence of smoking/vaping habits
Studijní plán
Jak je studie koncipována?
Detaily designu
- Primární účel: Léčba
- Přidělení: Randomizované
- Intervenční model: Paralelní přiřazení
- Maskování: Dvojnásobek
Počet zbraní
Zbraně a zásahy
Skupina účastníků / ArmSkupina účastníků / Arm |
Intervence / LéčbaIntervence / Léčba |
|---|---|
|
Aktivní komparátor: Group I: 28 veneers will be done using 3D printing technology (VarseoSmile TriniQ, Bego)
|
A total of fifty-six anterior indirect veneers will be fabricated using 3D printing and milling technologies.
The veneers will be divided into two groups according to the technique of fabrication.
Group I: 28 veneers will be done using 3D printing technology (VarseoSmile TriniQ, Bego), and group II: 28 veneers will be done using milling technology (Cerasmart 270, GC).
Veneer restorations will be fabricated checked, and cemented, then will be evaluated using the modified FDI criteria at baseline, three months, six months, and one year.
Moreover, color stability and surface wear of the restorations will be evaluated in each follow-up session.
|
|
Aktivní komparátor: group II: 28 veneers will be done using milling technology (Cerasmart 270, GC)
|
A total of fifty-six anterior indirect veneers will be fabricated using 3D printing and milling technologies.
The veneers will be divided into two groups according to the technique of fabrication.
Group I: 28 veneers will be done using 3D printing technology (VarseoSmile TriniQ, Bego), and group II: 28 veneers will be done using milling technology (Cerasmart 270, GC).
Veneer restorations will be fabricated checked, and cemented, then will be evaluated using the modified FDI criteria at baseline, three months, six months, and one year.
Moreover, color stability and surface wear of the restorations will be evaluated in each follow-up session.
|
Co je měření studie?
Primární výstupní opatření
Primární výstupní opatření
Měření výsledku |
Popis opatření |
Časové okno |
|---|---|---|
|
The functional properties of the examined veneer restorations
Časové okno: 1 year
|
All veneers were assessed clinically at 1 week (baseline) and subsequently at 3, 6, and 12 months, following the FDI evaluation criteria and scoring system, which indicates: Functional properties: (F1) Fracture of material and retention.
(F2) Marginal adaptation.
(F3) Proximal contact point.
(F4) Form and contour.
(F5) Occlusion and wear.
Each evaluated property was scored according to the FDI criteria using the following clinical scores: Score 1: Clinically excellent/very good (VG), Score 2: Clinically good (CG), score 3: Clinically satisfactory (CS), score 4: Clinically unsatisfactory (CU), score 5: Clinically poor (PO).
|
1 year
|
|
The biological properties of the examined veneer restorations
Časové okno: 1 year
|
All Veneers were assessed clinically at 1 week (baseline) and subsequently at 3, 6, and 12 months, following the revised FDI evaluation criteria and scoring system, which indicates: Biological properties (B1) Caries at restoration margins.
(B2) Dental hard tissue defects at the restoration margin.
(B3) Postoperative hypersensitivity and pulpal status.
Each evaluated property was scored according to the FDI criteria using the following clinical scores: Score 1: Clinically excellent/very good (VG), Score 2: Clinically good (CG), Score 3: Clinically satisfactory (CS), Score 4: Clinically unsatisfactory (CU), Score 5: Clinically poor (PO).
|
1 year
|
|
The aesthetic properties of the examined veneers
Časové okno: 1 year
|
All veneers were assessed clinically at 1 week (baseline) and subsequently at 3, 6, and 12 months, following the FDI evaluation criteria and scoring system, which indicates: Aesthetic properties: (A1) Surface luster and surface texture.
(A2) Marginal staining.
(A3) Color match.
Each evaluated property was scored according to the FDI criteria using the following clinical scores: Score 1: Clinically excellent/very good (VG), Score 2: Clinically good (CG), Score 3: Clinically satisfactory (CS), Score 4: Clinically unsatisfactory (CU), Score 5: Clinically poor (PO).
|
1 year
|
|
The color stability of the examined veneers
Časové okno: 1 year
|
All Veneers were assessed clinically at 1 week (baseline) and subsequently at 3, 6, 9, and 12 months using the vita easy shade spectrophotometer.
The CIEDE2000 formula will be used to measure the color change.
|
1 year
|
|
Wear resistance of the examined veneers
Časové okno: 1 year
|
All Veneers were scanned clinically using an intra oral scanner at 1 week (baseline) and subsequently at 3, 6, and 12 months.
The different scans were compared to baseline scan to assess the volume loss and accordingly the wear resistant.
|
1 year
|
Spolupracovníci a vyšetřovatelé
Sponzor
Sponzor
Termíny studijních záznamů
Hlavní termíny studia
Začátek studia (Aktuální)
Začátek studia
Primární dokončení (Aktuální)
Primární dokončení
Dokončení studie (Aktuální)
Dokončení studie
Termíny zápisu do studia
První předloženo
První předloženo
První předloženo, které splnilo kritéria kontroly kvality
První předloženo, které splnilo kritéria kontroly kvality
První zveřejněno (Aktuální)
První zveřejněno
Aktualizace studijních záznamů
Poslední zveřejněná aktualizace (Aktuální)
Poslední zveřejněná aktualizace
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Odeslaná poslední aktualizace, která splnila kritéria kontroly kvality
Naposledy ověřeno
Naposledy ověřeno
Více informací
Termíny související s touto studií
Klíčová slova
Další identifikační čísla studie
Další identifikační čísla studie
- 9262109
Informace o lécích a zařízeních, studijní dokumenty
Studuje lékový produkt regulovaný americkým FDA
Studuje produkt zařízení regulovaný americkým úřadem FDA
Tyto informace byly beze změn načteny přímo z webu clinicaltrials.gov. Máte-li jakékoli požadavky na změnu, odstranění nebo aktualizaci podrobností studie, kontaktujte prosím register@clinicaltrials.gov. Jakmile bude změna implementována na clinicaltrials.gov, bude automaticky aktualizována i na našem webu .